{"product_id":"honeywell-cc-puio01-51454205-175-experion-c300-universal-process-i-o-module","title":"Honeywell CC-PUIO01 51454205-175 Experion C300 Universal Process I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PUIO01\u003c\/strong\u003e \u003cstrong\u003e51454205-175\u003c\/strong\u003e is a Universal Process I\/O Module designed for interfacing with analog input, analog output, digital input, and digital output field devices within Experion Series-C I\/O systems. Each channel on the module is individually software-configurable to support current-based Analog Input (2, 3, or 4-wire devices), Analog Output, Digital Input, Digital Output, or Pulse Input on channels 15 through 18. Integrated with 16-bit A\/D converter resolution and HART 7 protocol support for analog channels, the module executes an input scan rate of 50 ms and includes channel-level electronic short-circuit protection alongside open wire detection capabilities.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSoftware-configurable channels supporting Analog Input, Analog Output, Digital Input, Digital Output, and Pulse Input (channels 15-18)\u003c\/li\u003e\n\u003cli\u003eHART 7 protocol support for analog input\/output communications\u003c\/li\u003e\n\u003cli\u003eChannel-level electronic short circuit protection with no damage to adjacent channels\u003c\/li\u003e\n\u003cli\u003eOpen wire detection and per-channel safe-state (FAILOPT) configurable behaviors\u003c\/li\u003e\n\u003cli\u003eFast Scan (Priority I\/O Module Scan) capability\u003c\/li\u003e\n\u003cli\u003eExtended ambient operating temperature range covering -40 to 70 degC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) process automation\u003c\/li\u003e\n\u003cli\u003eProcess plant field instrument signal aggregation and control\u003c\/li\u003e\n\u003cli\u003eZone 2 \/ Division 2 hazardous location energy limited\/nonincendive field wiring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eModule Model Number\u003c\/td\u003e\n\u003ctd\u003eCC-PUIO01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAssembly Part Number\u003c\/td\u003e\n\u003ctd\u003e51454205-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003e32 channels maximum per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCompatible Non-Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TUIO01 (12 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCompatible Redundant IOTA\u003c\/td\u003e\n\u003ctd\u003eCC-TUIO11 (18 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent (2, 3, or 4 wire devices)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0-20 mA or 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eA\/D Converter Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 Ohm nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput Scan Rate\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHardware Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% of full-scale (23.5 +\/- 2 degC), 0.17% of full-scale (-40 to 70 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMaximum Input Voltage\u003c\/td\u003e\n\u003ctd\u003e+36 VDC to -1.1 VDC (return terminal connected to common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNormal Mode Rejection Ratio\u003c\/td\u003e\n\u003ctd\u003e12 dB at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNormal Mode Filter Response\u003c\/td\u003e\n\u003ctd\u003eSingle pole, -3 dB at 16 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCrosstalk\u003c\/td\u003e\n\u003ctd\u003e60 dB (dc to 60 Hz channel-to-channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput Filter\u003c\/td\u003e\n\u003ctd\u003eFirst-order low-pass 16 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTransmitter Power Conditioning\u003c\/td\u003e\n\u003ctd\u003eCurrent limited to 24 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported Channels\u003c\/td\u003e\n\u003ctd\u003eChannels 15, 16, 17, 18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMinimum Pulse Width\u003c\/td\u003e\n\u003ctd\u003e50 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003eAny duty cycle meeting minimum pulse width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOTA Compatibility:\u003c\/strong\u003e Install non-redundant configurations using the CC-TUIO01 12-inch IOTA board, or redundant configurations using the CC-TUIO11 18-inch IOTA board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Wiring:\u003c\/strong\u003e AI, AO, and DI channels are protected to support energy limited \/ nonincendive field wiring connections for Zone 2 \/ Division 2 hazardous locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Immunity:\u003c\/strong\u003e Signal lines can be shorted in the field without damaging the module or affecting adjacent channels.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52679512752491,"sku":"CC-PUIO01 51454205-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CC-PUIO01-51454205-175_003_1200x1200_707234f9-e56f-443f-a322-3dd576be10f3.jpg?v=1786433930","url":"https:\/\/www.plcprotech.com\/products\/honeywell-cc-puio01-51454205-175-experion-c300-universal-process-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}