{"product_id":"honeywell-cc-pwr401-experion-series-c-power-system-module","title":"Honeywell CC-PWR401 Experion Series C Power System Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PWR401\u003c\/strong\u003e is a 40 Ampere power system module engineered to supply 24 Vdc power within Honeywell control system enclosures. Constructed as a 40 Amp power rack populated with three 24 Vdc (20 A) output power supplies, the assembly delivers up to 40 Amperes of redundant system power.\u003c\/p\u003e\n\u003cp\u003eOperating from standard 120\/240 VAC line power across a 47 to 63 Hz frequency range, each individual 24 Vdc power supply unit can be powered by an independent AC source, such as separate mains feeds or an Uninterruptible Power Supply (UPS). The system maintains a regulated 25 to 26 Vdc output under normal AC input conditions, capped at a maximum of 20 Amperes from any single DC output connector.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eCC-PWR401\u003c\/strong\u003e is designed specifically for direct AC-to-DC conversion and does not support battery backup integration. Its multi-supply modular structure provides continuous operation and power distribution for industrial process automation racks and cabinet control equipment.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e40 A Power Capacity:\u003c\/strong\u003e Houses three 20 A output power supply units inside a dedicated 40 A power rack chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Power Configuration:\u003c\/strong\u003e Delivers 40 Amperes total output with failure-tolerant multi-supply architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndependent Input Feeds:\u003c\/strong\u003e Allows each individual 24 Vdc power supply to connect to separate AC line or UPS power sources.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulated DC Output:\u003c\/strong\u003e Provides steady 25 to 26 Vdc output voltage under normal operating conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Current Limiting:\u003c\/strong\u003e Built-in output rating limits maximum current to 20 Amperes per individual DC output connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Temperature Rating:\u003c\/strong\u003e Built to operate across industrial ambient temperatures ranging from -40 degC to +70 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Frequency Acceptance:\u003c\/strong\u003e Accommodates AC line input frequencies from 47 to 63 Hz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Control Cabinets:\u003c\/strong\u003e Delivers primary 24 Vdc power to Honeywell DCS control racks and field I\/O systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Power Infrastructure:\u003c\/strong\u003e Provides dual-feed power distribution for critical control loops requiring isolated AC power inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Power Distribution:\u003c\/strong\u003e Functions as the central 24 Vdc system supply within industrial automation control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eCC-PWR401\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower System Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e25 to 26 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal System Current\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndividual Supply Rating\u003c\/td\u003e\n\u003ctd\u003e20 A per power supply unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Rating\u003c\/td\u003e\n\u003ctd\u003e20 A maximum per DC output connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Power Supply Count\u003c\/td\u003e\n\u003ctd\u003e3 power supply units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Redundancy\u003c\/td\u003e\n\u003ctd\u003eSupported (Redundant configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Backup Capability\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel Type\u003c\/td\u003e\n\u003ctd\u003eControl Panel \/ Power Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Connections\u003c\/td\u003e\n\u003ctd\u003eIndependent AC line inputs for each internal 24 Vdc power supply unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Output Connectors\u003c\/td\u003e\n\u003ctd\u003e24 Vdc output power terminals (rated at max 20 A per individual connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Unpack the CC-PWR401 power rack and verify that all three 24 Vdc supply units are properly seated in the chassis prior to mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Source Allocation:\u003c\/strong\u003e To achieve true power redundancy, connect each internal power supply to an independent AC power circuit or UPS line feed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Output Wiring:\u003c\/strong\u003e Route 24 Vdc distribution cables ensuring total current draw on any individual DC output connector does not exceed the 20 Ampere limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Clearance:\u003c\/strong\u003e Mount the module within the enclosure allowing adequate vertical airflow to maintain operating temperatures within the -40 degC to +70 degC envelope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Verify proper protective conductor grounding to the chassis frame before energizing AC input power.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eReplacement Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Verification:\u003c\/strong\u003e Prior to replacing an existing power rack unit, verify that the connected 24 Vdc field load does not exceed the 40 A total system rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Feed Isolation:\u003c\/strong\u003e Disconnect incoming AC line power feeds before handling main power wiring during complete system replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePost-Replacement Checks:\u003c\/strong\u003e Measure output terminals post-installation to confirm DC voltage remains within the nominal 25 to 26 Vdc specification.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52679527924075,"sku":"CC-PWR401","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CC-PWR401_001_1200x1200_70436600-353a-4f8a-a00d-1e4c2bd4ccf1.jpg?v=1786754000","url":"https:\/\/www.plcprotech.com\/products\/honeywell-cc-pwr401-experion-series-c-power-system-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}