{"product_id":"honeywell-cc-tdod51-experion-series-c-non-redundant-digital-output-iota","title":"Honeywell CC-TDOD51 Experion Series C Non-Redundant Digital Output IOTA","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TDOD51\u003c\/strong\u003e is a non-redundant Digital Output Input Output Termination Assembly (IOTA) designed for the Experion Series C platform. It serves as the physical field termination interface for the \u003ca href=\"\/products\/honeywell-cc-pdod51-series-c-24vdc-digital-output-module-sink-open-drain-coated\"\u003e\u003cstrong\u003eCC-PDOD51\u003c\/strong\u003e\u003c\/a\u003e 24VDC sink-type digital output module, allowing process control signals to interface directly with actuators, solenoid valves, and interposing relays.\u003c\/p\u003e\n\u003cp\u003eOperating within the Honeywell C300 controller architecture, the \u003cstrong\u003eCC-TDOD51\u003c\/strong\u003e provides streamlined signal distribution and terminal connection points without requiring external marshalling. Field wiring attaches directly to the two-level detachable terminal block, which accepts wiring up to 12 AWG (2.5 mm squared).\u003c\/p\u003e\n\u003cp\u003eThe assembly features conformal coating to withstand harsh industrial environments and incorporates electronic overcurrent protection. By distributing power across the bused backplane and housing the \u003cstrong\u003eCC-PDOD51\u003c\/strong\u003e output module, the assembly delivers reliable control switching for discrete automation circuits.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Sink Architecture:\u003c\/strong\u003e Specifically engineered for 32-channel 24VDC open-drain (sink) digital output operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Footprint:\u003c\/strong\u003e Compact 9-inch (228 mm) non-redundant form factor optimizes enclosure space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e Standard board protection against moisture, dust, and aggressive industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetachable Terminations:\u003c\/strong\u003e Two-level detachable screw terminal blocks simplify initial installation, testing, and field maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Power Distribution:\u003c\/strong\u003e Receives 24VDC power directly through the bused IOTA carrier, eliminating extra field power wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Offers 1000 VAC RMS system-to-field isolation when utilizing an external field power supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolenoid Valve Control:\u003c\/strong\u003e Direct switching of 24VDC process solenoids and pneumatic actuators in process plants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterposing Relay Driving:\u003c\/strong\u003e Interfacing low-current digital outputs to higher-power control circuits and motor starters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Alarm Indication:\u003c\/strong\u003e Controlling panel-mounted status lamps, annunciators, and field beacons.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral Process Automation:\u003c\/strong\u003e Integrated discrete output switching for chemical, oil and gas, power generation, and manufacturing facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TDOD51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eExperion Series C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Module\u003c\/td\u003e\n\u003ctd\u003eCC-PDOD51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eNon-Redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSink (Open Drain)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e15 VDC to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e0.1 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e1000 VAC RMS (System-to-Field)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e0 VDC typical (at 0.1 A max load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Off-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e100 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Time\u003c\/td\u003e\n\u003ctd\u003e10 ms (Turn-On \/ Turn-Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Width \/ Size\u003c\/td\u003e\n\u003ctd\u003e9 inches (228 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Wiring Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 12 AWG (2.5 mm sq) stranded wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eConformally Coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal \/ Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOM Mounting Slot\u003c\/td\u003e\n\u003ctd\u003eDirect plug-in interface for CC-PDOD51 Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring Terminals\u003c\/td\u003e\n\u003ctd\u003eTwo-level detachable screw terminals for 32 output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Bus Connections\u003c\/td\u003e\n\u003ctd\u003eScrewed mechanical\/electrical connection to the 24VDC bused carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturn \/ Ground Common\u003c\/td\u003e\n\u003ctd\u003eShared field return (ground) reference for sink-configured output loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Precaution:\u003c\/strong\u003e Disconnect system power before mounting or wiring the IOTA assembly to prevent electrical shock or hardware damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Mounting:\u003c\/strong\u003e Secure the \u003cstrong\u003eCC-TDOD51\u003c\/strong\u003e onto the cabinet channel\/carrier, ensuring firm contact with the 24VDC bus power distribution screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Land field output lines onto the two-level detachable terminal block using wire sizes up to 12 AWG (2.5 mm squared). Confirm output polarity matches the sink configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Carefully align and plug the \u003cstrong\u003eCC-PDOD51\u003c\/strong\u003e Digital Output Module into the designated IOTA slot until fully seated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Power Verification:\u003c\/strong\u003e Verify wiring tightness, ensure proper grounding, and confirm field load currents do not exceed 0.1 A per channel.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Commissioning \/ Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Fail-Safe Setup:\u003c\/strong\u003e Configure the FAILOPT parameter (Hold Last Value or Shed to Safe Value) via Experion Control Builder software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Mode Selection:\u003c\/strong\u003e Program channels for latched, pulsed, or pulse-width modulated (PWM) operation based on application needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swapping Module:\u003c\/strong\u003e The \u003cstrong\u003eCC-PDOD51\u003c\/strong\u003e IOM can be removed or replaced on the \u003cstrong\u003eCC-TDOD51\u003c\/strong\u003e IOTA without disturbing the field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning Verification:\u003c\/strong\u003e Exercise output channels through software override tools to verify field device state transitions and switching times under 10 ms.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668010594667,"sku":"CC-TDOD51","price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CC-TDOD51_001_1200x1200_26d3a4f0-302f-4494-95cc-3d1e9b2ff2f8.jpg?v=1786760657","url":"https:\/\/www.plcprotech.com\/products\/honeywell-cc-tdod51-experion-series-c-non-redundant-digital-output-iota","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}