{"product_id":"honeywell-experion-pks-tk-smpc01-sim-fta-power-adapter","title":"Honeywell EXPERION PKS TK-SMPC01 SIM FTA Power Adapter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TK-SMPC01\u003c\/strong\u003e is a conformal-coated, high-reliability \u003cstrong\u003eSIM FTA Power Adapter\u003c\/strong\u003e designed for use within the \u003cstrong\u003eHoneywell Experion PKS\u003c\/strong\u003e (Process Knowledge System) architecture. It functions as the dedicated power regulation and interface component for the Serial Interface Module (SIM) Field Termination Assembly (FTA), establishing a reliable hardware infrastructure to power communications between qualified third-party serial devices and Experion C200 or C300 controllers via the MODBUS or Allen-Bradley DF1 protocols.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eTK-SMPC01\u003c\/strong\u003e module handles wide-range alternating current inputs from 85 to 265 Vac, making it highly versatile for global industrial electrical distribution systems. It accommodates flexible installations with integrated options to mount on standard DIN rails or flat surfaces inside or outside marshalling cabinets. The \"TK\" prefix specifies that this assembly features a robust conformal coating, providing enhanced environmental resilience against moisture, airborne contaminants, and corrosive atmospheres typical of severe industrial processing environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWide-range input capability accepting standard 85 to 265 Vac distribution power.\u003c\/li\u003e\n\u003cli\u003eFully conformal-coated hardware layer (\"TK\" model) for superior atmospheric corrosion resistance.\u003c\/li\u003e\n\u003cli\u003eSeamless power delivery optimized specifically for Experion PKS SIM FTA modules.\u003c\/li\u003e\n\u003cli\u003eSupports high-availability long-distance topologies up to 300 meters from the power adapter to the FTA.\u003c\/li\u003e\n\u003cli\u003eHighly flexible mechanical design supporting simple DIN rail or direct flat surface mounting.\u003c\/li\u003e\n\u003cli\u003eBuilt-in robust protection profiles including high ESD and surge safeguards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) power infrastructures\u003c\/li\u003e\n\u003cli\u003ePowering Modbus RTU (RS232 \/ RS485) and Allen-Bradley DF1 Serial Interface FTAs\u003c\/li\u003e\n\u003cli\u003eAsset management and third-party subsystem interface links\u003c\/li\u003e\n\u003cli\u003eHeavy industrial automation deployments in harsh or corrosive environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eTK-SMPC01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eSIM FTA Power Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eSystem Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eExperion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e85 to 265 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eLine Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eMaximum Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e12 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eInterface Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eEIA-RS232-D \/ EIA-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eMax Power Adapter to FTA Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e300 meters (984 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eMaximum Baud Rate Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e19,200 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eCommon Mode Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e250 Vrms (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003eESD Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eIEEE SWC 472-1974 \/ IEEE 801.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003eSurge Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003eIEEE SWC 472-1974\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003eDIN rail or flat surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003e\u003cstrong\u003eCoated Version Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003eYes (TK prefix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Setup:\u003c\/strong\u003e Mount the adapter securely onto a standard industrial DIN rail or screw it tightly to a flat panel surface. Grasp both rail mount adapters on the tapered side and apply direct pressure when locking it onto a DIN rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing and Distance:\u003c\/strong\u003e Connect the SIM-to-Power Adapter cable (TC-KSM003\/005\/010) between the controller chassis SIM and the power adapter. Ensure the separate Power Adapter-to-FTA cable (MU-KLAM or MU-KSX series) does not exceed the maximum engineering distance of 300 meters (984 feet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Verify that the primary mains source is completely turned off before inserting or routing power cable leads into the designated AC connector blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Precautions:\u003c\/strong\u003e Always observe standard ESD hazard mitigation procedures when performing mechanical installation, terminal assignments, or field servicing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIEEE SWC 472-1974\u003c\/li\u003e\n\u003cli\u003eIEEE 801.2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the core function of the TK-SMPC01 power adapter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt accepts wide-range alternating current to safely regulate and distribute power directly to the Serial Interface Module Field Termination Assembly in an Experion system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the TC-SMPC01 and the TK-SMPC01 models?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe model number with the TK prefix denotes a fully conformal-coated version designed to protect internal electronics against harsh, humid, or corrosive industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific range of input voltage does this power adapter accept?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis unit accepts any incoming alternating current voltage between 85 and 265 Vac.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat line frequencies are supported by the AC input stage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AC electrical stage supports nominal system frequencies ranging from 47 to 63 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the absolute maximum power consumption of this assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe maximum power consumption rating for the device is exactly 12 W.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow far away can the power adapter be located from the corresponding SIM FTA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe maximum permissible field routing distance between the power adapter and the destination FTA is 300 meters (984 feet).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this device be used with direct current input systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this model is designed for 85 to 265 Vac installations. For direct current applications, the 24 Vdc model (TK-SMPD01) should be utilized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat types of physical mounting configurations are supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe physical chassis is designed with multi-use provisions allowing for secure DIN rail attachment or direct flat surface mounting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this hardware support multiple serial interface protocols on the connected FTA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it powers the FTAs that communicate via standard Modbus RTU (RS232\/RS485) and Allen-Bradley DF1 asynchronous serial configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat transient or surge protections are engineered into this device?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features integrated safety layers that comply with IEEE SWC 472-1974 and IEEE 801.2 standards for ESD and surge protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat steps are required to safely remove a failed power adapter from a DIN rail?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTurn off the power source, disconnect the power and interface cables, grasp both rail mount adapters on the tapered side, and pull forward slightly to pop the adapter off the rail.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705318044011,"sku":"TK-SMPC01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tk-smpc01-vko2kwhhz2m_da8e8763-23d9-4dbd-b931-dd1b04355b4f.jpg?v=1766639693","url":"https:\/\/www.plcprotech.com\/products\/honeywell-experion-pks-tk-smpc01-sim-fta-power-adapter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}