{"product_id":"honeywell-fc-iochas-0001s-safety-manager-i-o-chassis","title":"Honeywell FC-IOCHAS-0001S Safety Manager I\/O Chassis","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-IOCHAS-0001S\u003c\/strong\u003e is a single I\/O chassis designed for process safety, emergency shutdown (ESD), and critical control applications in industrial environments. Constructed to accommodate Safety Manager I\/O modules and associated bus components, the assembly features a 19-inch rack-mountable form factor with integrated backplane interconnects, key coding positions, and power distribution interfaces for process automation architectures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for single Safety Manager controller configurations requiring dedicated I\/O expansion.\u003c\/li\u003e\n\u003cli\u003eEquipped with backplane connectors featuring SOURIAU 5159 mechanical key coding pin positions to prevent module misplacement.\u003c\/li\u003e\n\u003cli\u003eProvides integrated bus printed circuit board (PCB) routing for internal 5 Vdc logic power distribution and watchdog signals.\u003c\/li\u003e\n\u003cli\u003eIncorporates card connector slots for standard input, output, and special-function modules.\u003c\/li\u003e\n\u003cli\u003eFeatures robust mechanical mounting design compatible with standard 19-inch cabinet frames and swing frame structures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety Instrumented Systems (SIS)\u003c\/li\u003e\n\u003cli\u003eEmergency Shutdown Systems (ESD)\u003c\/li\u003e\n\u003cli\u003eFire and Gas Detection Systems (F\u0026amp;G)\u003c\/li\u003e\n\u003cli\u003eBurner Management Systems (BMS) and Boiler Protection\u003c\/li\u003e\n\u003cli\u003eCritical Process Control in Chemical, Petrochemical, and Energy Plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFC-IOCHAS-0001S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafety Manager I\/O Chassis (Single)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSub-assembly \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIOCHAS-0001S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConformal Coated (FC Prefix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 degC to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSinusoidal Vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 57 Hz: 0.075 mm amplitude; 57 to 150 Hz: 1 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 G peak acceleration (11 ms pulse duration, 3 axes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24 Vdc Supply Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Vdc (+30% \/ -15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKey Coding System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSOURIAU type 5159 (pins 5159.009.17.22)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Mount:\u003c\/strong\u003e Install the chassis securely inside a standard cabinet or 180-degree swing frame using appropriate captive nuts and mounting hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Keying:\u003c\/strong\u003e Ensure that all backplane chassis pin positions are properly populated with SOURIAU 5159 coding pins matching the intended I\/O module type prior to card insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower \u0026amp; Logic Connections:\u003c\/strong\u003e Verify proper termination of the 5 Vdc supply line, 24 Vdc power bus, and watchdog signal lines via dedicated distribution boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the chassis frame directly to the cabinet safety earth bar using approved earthing straps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation:\u003c\/strong\u003e Maintain unobstructed vertical airflow across all installed card slots to ensure operation within specified thermal limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61508 \/ IEC 61511:\u003c\/strong\u003e Functional safety up to SIL 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61010-1 \/ IEC 61131-2:\u003c\/strong\u003e Safety requirements and equipment specifications for programmable controllers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61000-6-2 \/ IEC 61326-3-1:\u003c\/strong\u003e Immunity for industrial and safety-related systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508 \/ UL 508A:\u003c\/strong\u003e Standard for Industrial Control Equipment \/ Industrial Control Panels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C22.2 No. 142:\u003c\/strong\u003e Process Control Equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFM3600 \/ FM 3611:\u003c\/strong\u003e Class I, Division 2, Groups A, B, C \u0026amp; D hazardous location compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667756904811,"sku":"FC-IOCHAS-0001S","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FS-IOCHAS-0001S_001_1200x1200_e5fbcd8d-9a34-40c5-b657-362718070cbf.jpg?v=1786425574","url":"https:\/\/www.plcprotech.com\/products\/honeywell-fc-iochas-0001s-safety-manager-i-o-chassis","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}