{"product_id":"honeywell-fc-sao-0220m-ccv1-0-safety-manager-safe-analog-output-module","title":"Honeywell FC-SAO-0220m CCV1.0 Safety Manager Safe Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-SAO-0220m\u003c\/strong\u003e is a Safe Analog Output Module featuring two 0(4)–20 mA output channels engineered for high-integrity safety control applications within the Honeywell Safety Manager system. Operating as a critical output interface, the module converts internal digital system logic commands into precise analog current loops to regulate modulating final control elements, valves, and positioners in safety-critical loops.\u003c\/p\u003e\n\u003cp\u003eDesigned with internal safety architecture, each channel contains a 12-bit D\/A converter for output signal generation and an integrated A\/D converter that continuously reads back the actual output value. Within a configured Diagnostic Test Interval, the module automatically tests output channels for output value accuracy (within ±5%), de-energization capability, and cross-talk between outputs. Each channel features a secondary means of de-energizing (SMOD), enabling the watchdog and processor to de-energize the output independently of the application command value.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-SAO-0220m\u003c\/strong\u003e features conformal coating on all internal electronic assemblies (designated by the FC- prefix) to protect against airborne contaminants, dust, and aggressive industrial environments. The output channels are galvanically isolated from both the 24 Vdc internal power supply and the 5 Vdc logic supply.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides two 0(4)–20 mA safe analog output channels configurable as active or passive loops.\u003c\/li\u003e\n\u003cli\u003eConformally coated PCB construction (FC- prefix) for reliable environmental protection.\u003c\/li\u003e\n\u003cli\u003eDual-converter architecture utilizes a 12-bit D\/A converter for driving current and an internal A\/D converter for continuous signal read-back and self-testing.\u003c\/li\u003e\n\u003cli\u003eIncorporates continuous self-diagnostics verifying output current accuracy within ±5%, de-energization ability, and channel cross-talk.\u003c\/li\u003e\n\u003cli\u003eSecondary Means of De-energizing (SMOD) allows the watchdog or main processor to force channels to a de-energized state.\u003c\/li\u003e\n\u003cli\u003eGalvanically isolated outputs from the 5 Vdc and 24 Vdc supply buses.\u003c\/li\u003e\n\u003cli\u003eSupports both non-redundant and redundant Safety Manager I\/O configurations starting as of Safety Builder release 120.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Instrumented Systems (SIS):\u003c\/strong\u003e Converts safety shutdown logic into precise 4–20 mA positioning signals for emergency isolation and modulating control valves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurner Management Systems (BMS):\u003c\/strong\u003e Manages fuel-to-air ratio valves and flue gas damper actuators requiring safety-certified continuous signal conditioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire \u0026amp; Gas (F\u0026amp;G) Mitigation Systems:\u003c\/strong\u003e Controls variable output speed drives and proportional deluge valves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Location Control:\u003c\/strong\u003e Interfaces with non-incendive field circuits in Class I, Division 2 environments via approved terminal assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eFC-SAO-0220m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Version\u003c\/td\u003e\n\u003ctd\u003eCCV1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafe Analog Output Module (0(4)–20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eConformal Coated (FC-Type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e4 TE, 3 HE (4 HP, 3U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical \u0026amp; Power Ratings\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Power Requirements\u003c\/td\u003e\n\u003ctd\u003e5 Vdc, 30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc, 65 mA + 30 mA per active output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWDG Input Current\u003c\/td\u003e\n\u003ctd\u003e0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanically isolated from 24 Vdc and 5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Pins\u003c\/td\u003e\n\u003ctd\u003e0 V 1 (d14) and 0 V 2 (d20) interconnected on module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eOutput Channels \u0026amp; Performance\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003eActive or Passive, 0–20 mA \/ 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\/A Converter Resolution\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.05 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive Loop Resistance\u003c\/td\u003e\n\u003ctd\u003eMaximum 600 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive Maximum Output Voltage\u003c\/td\u003e\n\u003ctd\u003e30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePassive External Voltage\u003c\/td\u003e\n\u003ctd\u003eMaximum 40 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePassive Minimum Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e≤ 7.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Voltage Accuracy\u003c\/td\u003e\n\u003ctd\u003eCurrent value ± 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowed Load Types\u003c\/td\u003e\n\u003ctd\u003eResistive or capacitive only (inductive loads report module fault)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eMechanical Keying\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Keying Holes\u003c\/td\u003e\n\u003ctd\u003eHoles A9, C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Keying Pins\u003c\/td\u003e\n\u003ctd\u003eLarge pins A9, C5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ed2\u003c\/td\u003e\n\u003ctd\u003eWatchdog (WDG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eb2\u003c\/td\u003e\n\u003ctd\u003eGround (GND)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ez2\u003c\/td\u003e\n\u003ctd\u003eLogic Power (+5 Vdc VCC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ed8\u003c\/td\u003e\n\u003ctd\u003eInternal Supply 24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ez8\u003c\/td\u003e\n\u003ctd\u003eSupply 0 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ed14\u003c\/td\u003e\n\u003ctd\u003e0 V 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ed16\u003c\/td\u003e\n\u003ctd\u003emA 1 (Channel 1 Current Output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ez16\u003c\/td\u003e\n\u003ctd\u003eLoop 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ed20\u003c\/td\u003e\n\u003ctd\u003e0 V 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ed22\u003c\/td\u003e\n\u003ctd\u003emA 2 (Channel 2 Current Output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ez22\u003c\/td\u003e\n\u003ctd\u003eLoop 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the \u003cstrong\u003eHoneywell FC-SAO-0220m\u003c\/strong\u003e module version (CCV1.0) matches system software project requirements.\u003c\/li\u003e\n\u003cli\u003eInspect the rear connector pins and keying hole locations (A9, C5) to ensure compatibility with the card guide positioning pins.\u003c\/li\u003e\n\u003cli\u003eEnsure power to the target chassis section is safely disconnected before inserting the card, or verify hot-swap suitability in redundant configurations.\u003c\/li\u003e\n\u003cli\u003eAlign the card edge with the 4 TE chassis guide rails and push firmly into the backplane until properly seated.\u003c\/li\u003e\n\u003cli\u003eConnect the 24 Vdc internal supply to prevent fault detection during automatic self-test procedures.\u003c\/li\u003e\n\u003cli\u003eShort-circuit any unused output channels (link terminal 2 with 3 for channel 1, or terminal 6 with 7 for channel 2 on the TSAO-0220m FTA) to prevent fault reporting during self-diagnostic execution.\u003c\/li\u003e\n\u003cli\u003eDo not connect inductive loads directly to the outputs; the module is designed exclusively for resistive or capacitive loads.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eMaintenance \u0026amp; Replacement Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Output Consideration:\u003c\/strong\u003e When replacing a module in redundant analog output configurations, note that a detected fault during self-testing may cause a minor current dip on the output before the Safety Manager switches control to the healthy redundant channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Inspection:\u003c\/strong\u003e If a channel fault LED lights up, verify that inductive loads have not been connected to the outputs and ensure that all unused channels are properly jumpered.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCE Marked\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTÜV Certified\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUL Listed\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCSA Certified\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Mutual (FM):\u003c\/strong\u003e FM 3611 Approved for Class I, Division 2, Groups ABCD and Class II, Division 2, Groups FG non-incendive field circuits in hazardous locations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667757887851,"sku":"FC-SAO-0220m CCV1.0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fc-sao-022m-safe-analog-output-module-ixf4ffxblwj_1f38be25-3863-4b38-ac15-fec94132755c.jpg?v=1765501663","url":"https:\/\/www.plcprotech.com\/products\/honeywell-fc-sao-0220m-ccv1-0-safety-manager-safe-analog-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}