{"product_id":"honeywell-fc-scnt02-51460114-17-safety-manager-sc-controller-module","title":"Honeywell FC-SCNT02 51460114-17 Safety Manager SC Controller Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-SCNT02\u003c\/strong\u003e is a controller module engineered for the Safety Manager SC system. It serves as a functional replacement for the FC-SCNT01 module within safety system architectures and can be swapped online without interrupting process operations. In redundant Safety Manager SC (SMSC) controller configurations, the module functions side-by-side with an existing FC-SCNT01 module.\u003c\/p\u003e\n\u003cp\u003eThe module supports DNP3 protocol outstation functionality starting with Safety Manager SC release R212, allowing the Safety Manager SC to operate as a DNP3 Outstation while communicating with a DNP3 Master such as an Experion Server or ControlEdge RTU. It also functions as a direct spare part for the FC-SCNT01 module, maintaining full operational feature parity with the legacy module.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDirect functional replacement and spare part for the FC-SCNT01 controller module\u003c\/li\u003e\n\u003cli\u003eOnline replacement capability without disrupting running operations\u003c\/li\u003e\n\u003cli\u003eRedundant operations support, functioning alongside an FC-SCNT01 module in SMSC controllers\u003c\/li\u003e\n\u003cli\u003eIntegrated DNP3 protocol outstation support (requires release R212)\u003c\/li\u003e\n\u003cli\u003eCompatible with Safety Manager SC software release R200.2 and higher\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety Instrumented Systems (SIS) and Emergency Shutdown (ESD) applications\u003c\/li\u003e\n\u003cli\u003eSafety Manager SC redundant controller configurations\u003c\/li\u003e\n\u003cli\u003eIndustrial SCADA telecontrol communication networks utilizing DNP3 protocol outstation integration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFC-SCNT02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Mumber\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e51460114-17\u003c\/td\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafety Manager SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Software Release\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafety Manager SC R200.2 and higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDNP3 Protocol Support Release\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSafety Manager SC R212 and higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Replacement Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOnline replacement \/ Hot Swap capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual redundant controller configuration with FC-SCNT01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnline Replacement:\u003c\/strong\u003e The module can be installed or replaced online in a running Safety Manager SC system without requiring a shutdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Pair Coexistence:\u003c\/strong\u003e In redundant controller setups, an FC-SCNT02 module can be installed alongside an existing FC-SCNT01 module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Prerequisites:\u003c\/strong\u003e Verify that the Safety Manager SC system software is at release R200.2 or higher before module installation, and release R212 or higher if utilizing DNP3 outstation features.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667735474539,"sku":"FC-SCNT02 51460114-176","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FC-SCNT02_1.jpg?v=1785591830","url":"https:\/\/www.plcprotech.com\/products\/honeywell-fc-scnt02-51460114-17-safety-manager-sc-controller-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}