{"product_id":"honeywell-fc-tsgash-1624p-safety-manager-field-termination-assembly","title":"Honeywell FC-TSGASH-1624P Safety Manager Field Termination Assembly","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-TSGASH-1624P V1.0\u003c\/strong\u003e is a safe gas and flame detector input Field Termination Assembly (FTA) designed as an interface module between 0–20 mA field transmitters and the \u003cstrong\u003eSAI-1620m\u003c\/strong\u003e safe high-density analog input module within Honeywell Safety Manager systems. Featuring 16 input channels, this assembly supports both safety-related and non-safety-related instrumentation loops in industrial safety instrumented systems (SIS).\u003c\/p\u003e\n\u003cp\u003eEach channel on the \u003cstrong\u003eFC-TSGASH-1624P V1.0\u003c\/strong\u003e incorporates a high-precision 500 Ohm resistor to convert input current signals into 0–4 VDC levels for processing by the \u003cstrong\u003eSAI-1620m\u003c\/strong\u003e module with 0.1% accuracy. To safeguard connected instrumentation and loop wiring, every channel is individually protected by a 500 mA fast-acting fuse. The module routes input signals to single or redundant \u003cstrong\u003eSAI-1620m\u003c\/strong\u003e modules using standard SICC-0001\/Lx system interconnection cables.\u003c\/p\u003e\n\u003cp\u003eIn addition to primary signal conversion, the \u003cstrong\u003eFC-TSGASH-1624P V1.0\u003c\/strong\u003e features dedicated interfaces for HART communication. By providing direct connection points for multiplexer solutions from MTL or Pepperl+Fuchs (P+F), the module enables online HART diagnostic passthrough without disrupting safety loop integrity. The assembly is built on a DIN EN rail snap-in footprint and powered via a 24 VDC external supply line.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-Channel Analog Interface:\u003c\/strong\u003e Accommodates up to sixteen 0–20 mA (0–25 mA maximum) gas and flame detector loops with a shared common 0 V connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecision Signal Conversion:\u003c\/strong\u003e High-accuracy 500 Ohm onboard resistors convert input current signals to 0–4 VDC output levels for the SAI-1620m module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividual Channel Fusing:\u003c\/strong\u003e Equipped with 500 mA Schurter fuses (5x20 mm) per channel to protect field power lines and field devices against short-circuit events.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated HART Multiplexer Support:\u003c\/strong\u003e Dedicated onboard CN2 and CN3 connectors enable direct integration with Pepperl+Fuchs and MTL HART multiplexer solutions using standard cable assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Shield Connections:\u003c\/strong\u003e Features 16 dedicated screw terminals designed for field cable shield grounding, optimizing noise immunity in critical monitoring applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Supply Voltage Monitoring:\u003c\/strong\u003e Allows Safety Manager software to continuously monitor connected 24 VDC supply voltage levels through the safe high-density analog input chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual DIN Rail Compatibility:\u003c\/strong\u003e Mounting provision supports both TS32 and TS35 x 7.5 DIN EN rails for flexible cabinet installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Instrumented Systems (SIS):\u003c\/strong\u003e Field wiring termination for combustible gas, toxic gas, and optical flame detectors connected to Honeywell Safety Manager systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Safety Management:\u003c\/strong\u003e Analog input signal conditioning and HART diagnostic integration for critical 2-wire and 3-wire field transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Asset Management Integration:\u003c\/strong\u003e Passthrough connection point for MTL4850 or Pepperl+Fuchs HART multiplexers to support remote instrument calibration and device health monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Model Number\u003c\/td\u003e\n\u003ctd\u003eFC-TSGASH-1624P V1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eTSGASH-1624P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafe Gas\/Flame Detector Input Field Termination Assembly (FTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eSafety Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 Analog Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical \u0026amp; Input Ratings\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Requirement\u003c\/td\u003e\n\u003ctd\u003e24 VDC external, 2.5 mA (without field loads)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Range\u003c\/td\u003e\n\u003ctd\u003e0–25 mA (0–20 mA nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e500 Ohm (+\/- 5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage to SAI-1620m\u003c\/td\u003e\n\u003ctd\u003e0–4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage to HART Multiplexer\u003c\/td\u003e\n\u003ctd\u003eMax. 11 V peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Series Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 2 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eProtection \u0026amp; Fusing\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Rating\u003c\/td\u003e\n\u003ctd\u003e500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Dimensions\u003c\/td\u003e\n\u003ctd\u003e5 x 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Manufacturer \u0026amp; Part Number\u003c\/td\u003e\n\u003ctd\u003eSchurter 0001.2501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Voltage Ratings\u003c\/td\u003e\n\u003ctd\u003e250 VAC \/ 300 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Derating Curve\u003c\/td\u003e\n\u003ctd\u003eLinear from 0.5 A at 25 degC to 0.35 A at 70 degC ambient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eMechanical \u0026amp; Environmental\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 104.948%;\" height=\"206\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 48.0167%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 51.5658%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0167%;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"width: 51.5658%;\"\u003e225 x 109 x 60 mm (8.86 x 4.29 x 2.36 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0167%;\"\u003eUsed Rail Length\u003c\/td\u003e\n\u003ctd style=\"width: 51.5658%;\"\u003e226 mm (8.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0167%;\"\u003eCompatible DIN EN Rails\u003c\/td\u003e\n\u003ctd style=\"width: 51.5658%;\"\u003eTS32 \/ TS35 x 7.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0167%;\"\u003eScrew Terminal Wire Diameter\u003c\/td\u003e\n\u003ctd style=\"width: 51.5658%;\"\u003eMax. 2.5 mm2 (AWG 14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0167%;\"\u003eScrew Terminal Strip Length\u003c\/td\u003e\n\u003ctd style=\"width: 51.5658%;\"\u003e7 mm (0.28 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.0167%;\"\u003eScrew Terminal Tightening Torque\u003c\/td\u003e\n\u003ctd style=\"width: 51.5658%;\"\u003e0.5 Nm (0.37 ft-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 109.072%;\" height=\"342\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 21.5534%;\"\u003e\u003cstrong\u003eInterface \/ Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 78.0583%;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.5534%;\"\u003eScrew Terminals 1 to 64\u003c\/td\u003e\n\u003ctd style=\"width: 78.0583%;\"\u003eField wiring connections arranged in 16 groups of 4 screw terminals, including dedicated channel ground terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.5534%;\"\u003eGround Screw Terminals\u003c\/td\u003e\n\u003ctd style=\"width: 78.0583%;\"\u003eTop left ground connections for earth bonding field cable shields\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.5534%;\"\u003ePower Connector (+)\u003c\/td\u003e\n\u003ctd style=\"width: 78.0583%;\"\u003ePin 1 connected to +24 VDC bus bar via Weidmuller BVZ 7.62HP\/02\/180F SN connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.5534%;\"\u003ePower Connector (-)\u003c\/td\u003e\n\u003ctd style=\"width: 78.0583%;\"\u003ePin 2 connected to 0 VDC bus bar via Weidmuller BVZ 7.62HP\/02\/180F SN connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.5534%;\"\u003eCN1 Connector\u003c\/td\u003e\n\u003ctd style=\"width: 78.0583%;\"\u003eInterface for SICC-0001\/Lx cable to SAI-1620m analog input module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.5534%;\"\u003eCN2 Connector\u003c\/td\u003e\n\u003ctd style=\"width: 78.0583%;\"\u003eDedicated interface for Pepperl+Fuchs HART multiplexer units (KFD0-HMS-16 or KFD2-HMM-16 via K-MH26 cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 21.5534%;\"\u003eCN3 Connector\u003c\/td\u003e\n\u003ctd style=\"width: 78.0583%;\"\u003eDedicated interface for MTL HART multiplexer units (MTL4850 via MTL FLAT20-2.2 cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Verify physical integrity and check that all 16 channel fuses (500 mA, 5x20 mm) are fully seated in their respective holders before mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Snap the assembly securely onto a standard TS32 or TS35 x 7.5 DIN rail within the control cabinet, allowing at least 226 mm of clear rail width.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Wiring Connection:\u003c\/strong\u003e Strip external 24 VDC power conductors to 8 mm (0.28 in). Connect the supply lines to the included keyed Weidmuller BVZ 7.62HP 2-pole plug, ensuring proper polarity (+ to Pin 1, - to Pin 2), and engage the red locking slides.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Signal Wiring:\u003c\/strong\u003e Connect 2-wire or 3-wire gas and flame detectors to screw terminal groups 1 through 64. Strip wires to 7 mm (0.28 in) and tighten terminal screws to a torque of 0.5 Nm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding:\u003c\/strong\u003e Connect individual field cable shield drain wires to the dedicated shield terminal on each channel group and bond cabinet earth ground to the top-left ground screw connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Interconnection:\u003c\/strong\u003e Connect the SICC-0001\/Lx cable from connector CN1 on the FTA to the primary (or redundant pair) SAI-1620m module in the Safety Manager chassis.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCommissioning \u0026amp; Maintenance Recommendations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Verification:\u003c\/strong\u003e Confirm that Safety Manager software detects normal external supply voltage levels across the assembly via the SAI-1620m module diagnostic interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Replacement:\u003c\/strong\u003e If a transmitter loop fails, check the corresponding channel fuse (F1 to F16). Replace blown fuses exclusively with Schurter 0001.2501 (500 mA, 5x20 mm, 250 VAC \/ 300 VDC) fuses to maintain safety compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Integration Check:\u003c\/strong\u003e When using external HART multiplexers, verify that the dedicated CN2 (P+F) or CN3 (MTL) ribbon cables are fully seated and that loop communications function without signal attenuation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e European Conformity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTUV:\u003c\/strong\u003e Safety Approved for High-Integrity Applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Listed:\u003c\/strong\u003e Underwriters Laboratories Standard Compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA Certified:\u003c\/strong\u003e Canadian Standards Association Certified\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668014920043,"sku":"FC-TSGASH-1624P V1.0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FC-TSGASH-1624P_001_1200x1200_6764ef9e-802b-48a1-ae32-2cc3667df357.jpg?v=1786975267","url":"https:\/\/www.plcprotech.com\/products\/honeywell-fc-tsgash-1624p-safety-manager-field-termination-assembly","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}