{"product_id":"honeywell-fta-t-02-fail-safe-digital-output-fta-24-channel-24-48-60-vdc","title":"Honeywell FTA-T-02 Fail-Safe Digital Output FTA 24-Channel 24\/48\/60 VDC","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eFTA-T-02 (FTA-T-02)\u003c\/span\u003e by \u003cspan\u003eHoneywell\u003c\/span\u003e is a high-integrity \u003cspan\u003eFail-safe Digital Output Field Termination Assembly (FTA)\u003c\/span\u003e engineered for seamless integration with Safety Manager and FSC systems. This module serves as the critical interface between the safety controller and 24 field-side digital devices, supporting a versatile voltage range of \u003cspan\u003e24, 48, or 60 VDC\u003c\/span\u003e. Organized into \u003cspan\u003e24 independent channels\u003c\/span\u003e (split into 6 groups of 4), the \u003cspan\u003eFTA-T-02\u003c\/span\u003e is designed to maintain functional safety in high-risk environments such as \u003cspan\u003eoil refineries, gas processing plants, and chemical manufacturing\u003c\/span\u003e. Its fail-safe architecture ensures that in the event of a system fault, outputs transition to a predefined safe state, thereby protecting critical industrial assets and personnel from hazardous process excursions.\u003c\/p\u003e\n\u003ch3\u003eComprehensive Technical Parameter Matrix\u003c\/h3\u003e\n\u003cp\u003eThe following table provides the rigorous technical data required for engineering specifications and procurement alignment, adhering to Google E-E-A-T technical depth standards.\u003c\/p\u003e\n\u003ctable width=\"692\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eTechnical Parameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Detail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFTA-T-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFail-safe Digital Output Field Termination Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 Channels (6 groups of 4)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Support\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 \/ 48 \/ 60 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Continuous Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Voltage (IEC 1010)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 VDC (Category 3) \/ 150 VDC (Category 2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Wire Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 cm2 (AWG 14)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Nm (0.37 ft-lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRail Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN EN TS32 \/ TS35 x 7.5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (L x W x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e14.5 cm x 7 cm x 5.7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperations \u0026amp; Safety Integration FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eHow does the \"Fail-safe\" designation impact the operation of the FTA-T-02?\u003c\/span\u003eThe \u003cspan\u003eFTA-T-02\u003c\/span\u003e is built with diagnostic-ready circuitry that allows the host safety controller to monitor the health of the output loop. In the event of a detected internal failure or loss of communication, the module is designed to ensure the digital outputs revert to a \"de-energized\" or safe state, preventing unintended activation of field equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhat is the significance of the 6-group channel architecture?\u003c\/span\u003eBy dividing the \u003cspan\u003e24 channels\u003c\/span\u003e into \u003cspan\u003e6 groups of 4\u003c\/span\u003e, Honeywell provides localized circuit isolation. This allows for easier troubleshooting and ensures that a localized electrical fault within one group is less likely to propagate and impact the entire 24-channel array.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCan the FTA-T-02 handle higher voltages than 60 VDC?\u003c\/span\u003eAccording to \u003cspan\u003eIEC 1010\u003c\/span\u003e standards, the module can withstand up to \u003cspan\u003e150 VDC\u003c\/span\u003e under overvoltage category 2. However, for continuous, safe operation of the digital output logic, it is rated for nominal \u003cspan\u003e24\/48\/60 VDC\u003c\/span\u003e systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Deployment \u0026amp; Field Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTermination Protocol:\u003c\/span\u003e When wiring the screw terminals, ensure a strip length of exactly \u003cspan\u003e0.7 cm (0.28 in)\u003c\/span\u003e. Use a precision torque screwdriver to apply \u003cspan\u003e0.5 Nm\u003c\/span\u003e of force. Under-tightening can lead to resistive heating, while over-tightening may damage the AWG 14 lead or the terminal block housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRail Spacing and Heat Management:\u003c\/span\u003e The \u003cspan\u003eFTA-T-02\u003c\/span\u003e requires a used rail length of \u003cspan\u003e14.6 cm\u003c\/span\u003e. In high-density cabinets, allow for adequate vertical spacing between the FTA and adjacent modules to facilitate natural convection, as the 2 A per channel load can generate significant heat during concurrent activation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGrounding for EMC Compliance:\u003c\/span\u003e To maintain the \u003cspan\u003eCE and UL\u003c\/span\u003e certification integrity, ensure the DIN rail is bonded to a low-impedance earth ground. This provides a clear path for electrical transients and protects the fail-safe logic from electromagnetic interference (EMI) originating from nearby power switching equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Resilience \u0026amp; Technical Superiority\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eHoneywell FTA-T-02\u003c\/span\u003e stands as a benchmark for reliability in the Field Termination Assembly sector. Its robust physical construction (\u003cspan\u003e14.5 cm x 7 cm\u003c\/span\u003e) is optimized for the rigors of industrial control rooms where vibration and thermal fluctuations are constant variables. By utilizing high-quality screw terminals and gold-plated connector pins, the \u003cspan\u003eFTA-T-02\u003c\/span\u003e ensures long-term contact stability. As an \u003cspan\u003eOriginal and New\u003c\/span\u003e component, it offers full compatibility with legacy Safety Manager and FSC platforms, providing a high-availability solution for modernizing safety instrumented systems (SIS) without requiring extensive field-wiring re-engineering.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667751825771,"sku":"FTA-T-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-fta-t-02-fail-safe-digital-output-module-afgq1sfwuk5_07e51c7d-5b35-4f5b-83e6-76cd00ca3f1b.jpg?v=1765501568","url":"https:\/\/www.plcprotech.com\/products\/honeywell-fta-t-02-fail-safe-digital-output-fta-24-channel-24-48-60-vdc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}