{"product_id":"honeywell-fta-t-08-fail-safe-digital-output-relay-fta-module","title":"Honeywell FTA-T-08 Fail-Safe Digital Output Relay FTA Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for high-integrity safety systems, the \u003cstrong\u003eHoneywell FTA-T-08\u003c\/strong\u003e is a 4-channel fail-safe digital output relay Field Termination Assembly (FTA). Designed to interface directly with safety-critical control modules such as the 10201\/2\/1, this unit provides robust galvanic isolation and contact multiplication for critical process shutdown and safety interlock loops. Each of the four channels features a redundant, diverse relay configuration utilizing devices from different manufacturers to mitigate common-cause failures and comply with rigorous functional safety requirements.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eFTA-T-08\u003c\/strong\u003e incorporates an integrated 3.15 AT slow-acting fuse on each normally open (NO) field contact, protecting field-side wiring and devices from unexpected overcurrent conditions. Local status diagnostics are indicated through on-board LEDs, facilitating prompt field troubleshooting. Connection to the primary controller rack is accomplished using specialized SIC-C-02 cables, maintaining optimal signal integrity across the termination assembly.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFour independent fail-safe digital output relay channels.\u003c\/li\u003e\n  \u003cli\u003eRedundant contact architecture featuring diverse relays from separate manufacturers to prevent common-mode failures.\u003c\/li\u003e\n  \u003cli\u003eIndividual channel protection via 3.15 AT slow-acting fuses on the output contacts.\u003c\/li\u003e\n  \u003cli\u003eIntegrated diagnostic LEDs for real-time channel status monitoring.\u003c\/li\u003e\n  \u003cli\u003eSilver alloy contacts designed for reliable and durable switching.\u003c\/li\u003e\n  \u003cli\u003eDirect integration compatibility with Honeywell 10201\/2\/1 modules using SIC-C-02 cable assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEmergency Shutdown Systems (ESD) in petrochemical and refinery environments.\u003c\/li\u003e\n  \u003cli\u003eBurner Management Systems (BMS) in power utility plants.\u003c\/li\u003e\n  \u003cli\u003eFire and Gas (F\u0026amp;G) mitigation control networks.\u003c\/li\u003e\n  \u003cli\u003eCritical safety interlock loops in chemical processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFTA-T-08 (3410713)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModule Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10201\/2\/1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e31 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelay Cut-in Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e19 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTypical Input Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 mA at 24 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.15 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e400 mA at 24 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Switched Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e250 Vac \/ 150 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Switched Load\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1250 VA \/ 150 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Switched Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eContact Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSilver alloy\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.15 AT (slow-acting), 5 x 20 mm or 5 x 25 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Lifecycles\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e80,000 operations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMechanical Lifecycles\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5,000,000 operations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Ambient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to +60 degC (-40 degF to +140 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Interface\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eT10 terminal connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFTA Connector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x 4F connector layout\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Interface Cable\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eSIC-C-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSignals per Cable\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4\/4 channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDe-energize all power sources before handling, mounting, or wiring the Field Termination Assembly.\u003c\/li\u003e\n  \u003cli\u003eMount the module securely on a standard DIN rail or enclosure backplate inside a dust-free, dry industrial cabinet.\u003c\/li\u003e\n  \u003cli\u003eIsolate and route the high-voltage relay wiring separately from low-voltage logic signal cables.\u003c\/li\u003e\n  \u003cli\u003eConfirm that the field load does not exceed the maximum rated capacity of the 3.15 AT internal fuses.\u003c\/li\u003e\n  \u003cli\u003eMaintain sufficient spacing between adjacent modules to ensure continuous convection cooling within the specified ambient temperature limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Compliant\u003c\/li\u003e\n  \u003cli\u003eTUV Safety Certified\u003c\/li\u003e\n  \u003cli\u003eUL Listed\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705567342955,"sku":"FTA-T-08","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FTA-T-08-b4u2nv44reh_0249fac8-287b-46ca-b16f-32b768da067c.jpg?v=1766650024","url":"https:\/\/www.plcprotech.com\/products\/honeywell-fta-t-08-fail-safe-digital-output-relay-fta-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}