{"product_id":"honeywell-lg1093aa24-lg1093-flame-sensor","title":"Honeywell LG1093AA24 LG1093 Flame Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eIndustrial combustion systems require highly reliable monitoring, and the \u003cstrong\u003eHoneywell LG1093AA24\u003c\/strong\u003e meets this demand as a rugged gas turbine flame sensor. Designed to detect ultraviolet radiation emitted by combustion flames, this industrial sensor provides rapid, precise signal transmission to flame safeguard controls. Built to withstand extreme mechanical and thermal stress, it features a robust housing and high-pressure window, making it suitable for hazardous and harsh process environments.\u003c\/p\u003e\n\n\u003cp\u003eThe sensor is pre-configured with a robust electrical interface featuring a Teflon-shielded cable to ensure signal integrity against electromagnetic interference (EMI). Its heavy-duty construction facilitates long-term deployment in utility boilers and power generation applications where continuous, uninterrupted flame supervision is critical.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHighly sensitive ultraviolet (UV) tube sensing technology for accurate flame verification.\u003c\/li\u003e\n  \u003cli\u003eDurable mechanical design suitable for extreme temperature and pressure environments.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Teflon-shielded connection cable prevents signal degradation from heat and electrical noise.\u003c\/li\u003e\n  \u003cli\u003eNPT standard threading for secure mounting onto process burner assemblies.\u003c\/li\u003e\n  \u003cli\u003eConduit connection interface simplifies integration into rigid or flexible electrical conduit systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial gas turbine flame supervision\u003c\/li\u003e\n  \u003cli\u003eHigh-capacity utility boiler systems\u003c\/li\u003e\n  \u003cli\u003ePetrochemical and refinery process burners\u003c\/li\u003e\n  \u003cli\u003eDistrict heating plant combustion monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\/Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLG1093AA24\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet Flame Sensor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/4 inch internal NPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Panel Connection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTeflon shielded cable with 1 inch external conduit thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degF to +350 degF (-40 degC to +177 degC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWindow Pressure Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e150 psig at 400 degF (10.3 bar at 204 degC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the sensor so that its line of sight is directed at the primary combustion zone, avoiding obstruction from burner components.\u003c\/li\u003e\n  \u003cli\u003eApply high-temperature thread sealant to the 3\/4 inch NPT interface to prevent process gas leakage.\u003c\/li\u003e\n  \u003cli\u003eRoute the Teflon-shielded cable away from high-voltage igniter leads to prevent electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eKeep the viewing window clean and free of soot or oil deposits by periodically executing maintenance cycles.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52679229866347,"sku":"LG1093AA24","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/lg1093aa24-q2qh4i4hypv_363dd88c-754d-4f62-a30f-2c7f44446e84.jpg?v=1765958110","url":"https:\/\/www.plcprotech.com\/products\/honeywell-lg1093aa24-lg1093-flame-sensor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}