{"product_id":"honeywell-lg1093ac05-lg1093-flame-detector","title":"Honeywell LG1093AC05 LG1093 Flame Detector","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell LG1093AC05\u003c\/strong\u003e is an industrial ultraviolet flame sensor designed for flame monitoring in gas turbine installations. Operating as part of the Honeywell LG\/EG flame monitoring system, the \u003cstrong\u003eLG1093AC05\u003c\/strong\u003e detects ultraviolet radiation emitted by hydrocarbon flames to signal flame or no-flame conditions. It incorporates a Geiger Mueller-type phototube sensor tolerant to black body radiation and solar blind across the 180 to 260 nm spectrum. Designed with a 1.73-inch O.D. mounting flange and a 24-foot (7.3 m) two-conductor armored cable, the unit interfaces directly with compatible EG1033 amplifier modules up to an operating distance of 1000 feet (330 m).\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh sensitivity with fast typical flame present response time of 0.1 seconds\u003c\/li\u003e\n\u003cli\u003eMaximum flame loss response time of 0.2 seconds\u003c\/li\u003e\n\u003cli\u003eSolar blind Geiger Mueller-type sensor phototube detecting 180 to 260 nm UV spectrum\u003c\/li\u003e\n\u003cli\u003eTolerant to black body radiation\u003c\/li\u003e\n\u003cli\u003e10,000 hours MTBF with two-year shelf life\u003c\/li\u003e\n\u003cli\u003e1.73 inch O.D. by 0.14 inch wide mounting flange\u003c\/li\u003e\n\u003cli\u003eIntegrated 24 ft (7.3 m) two-conductor armored cable\u003c\/li\u003e\n\u003cli\u003eViewing window rated for 6.3 psig (428 mbar) pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral Electric (and GE licensee) industrial gas turbines\u003c\/li\u003e\n\u003cli\u003ePower generation land-based and off-shore gas turbine units\u003c\/li\u003e\n\u003cli\u003ePumping station gas turbine drives\u003c\/li\u003e\n\u003cli\u003eMarine and shipboard power generation turbines\u003c\/li\u003e\n\u003cli\u003eIndustrial gas compressor drives\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eLG1093AC05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003eGeiger Mueller-type phototube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Range\u003c\/td\u003e\n\u003ctd\u003e180 to 260 nm (1800 to 2600 angstroms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Interface\u003c\/td\u003e\n\u003ctd\u003e1.73 inch O.D. by 0.14 inch wide flange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eTwo-conductor armored cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e24 ft (7.3 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 176 degC (-40 degF to +350 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWindow Pressure Rating\u003c\/td\u003e\n\u003ctd\u003e6.3 psig (428 mbar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlame Detect Time\u003c\/td\u003e\n\u003ctd\u003eTypical 0.1 sec (max 1.0 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlame Loss Detect Time\u003c\/td\u003e\n\u003ctd\u003e0.2 sec max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Transmission Distance\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 ft (330 m) sensor to amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e10,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShelf Life\u003c\/td\u003e\n\u003ctd\u003eTwo-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Amplifiers\u003c\/td\u003e\n\u003ctd\u003eEG1033AA, EG1033AB, EG1033AC, EG1033AD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3 Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure proper mechanical alignment of the 1.73-inch mounting flange against the turbine viewing port.\u003c\/li\u003e\n\u003cli\u003eVerify viewing window pressure limits do not exceed the 6.3 psig rating during operating conditions.\u003c\/li\u003e\n\u003cli\u003eRoute the 24-foot armored cable avoiding extreme bend radii, high mechanical impact zones, or direct abrasion.\u003c\/li\u003e\n\u003cli\u003eMaintain complete shield and ground continuity back to the EG1033 series amplifier terminal connections.\u003c\/li\u003e\n\u003cli\u003eKeep maximum cable runs between the sensor and amplifier within 1000 feet (330 m).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE Mark: EMC Directive 89\/336\/EEC\u003c\/li\u003e\n\u003cli\u003eATEX Directive 94\/9\/EC: EEx d IIA T3 or EEx d IIC T3 (Zone 1 and 2)\u003c\/li\u003e\n\u003cli\u003eFactory Mutual: Class I, Division 1 and 2, Groups B, C, and D\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53619531645291,"sku":"LG1093AC05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/LG1093AC05.jpg?v=1785234006","url":"https:\/\/www.plcprotech.com\/products\/honeywell-lg1093ac05-lg1093-flame-detector","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}