{"product_id":"honeywell-mc-taih14-51305887-150-experion-pks-high-level-analog-input-hart-fta-module","title":"Honeywell MC-TAIH14 51305887-150 Experion PKS High Level Analog Input HART FTA Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MC-TAIH14\u003c\/strong\u003e (Part Number: \u003cstrong\u003e51305887-150\u003c\/strong\u003e) is a High Level Analog Input HART Field Termination Assembly (HLAIHART FTA) designed for integration within Honeywell Process Manager (PM), Advanced Process Manager (APM), High Performance Process Manager (HPM), and Experion Process Knowledge System (PKS) I\/O architectures. Acting as the direct physical interface between field-mounted process transmitters and system Input\/Output Processors (IOPs), the assembly channels 16 analog input signals while facilitating pass-through Highway Addressable Remote Transducer (HART) digital communication.\u003c\/p\u003e\n\u003cp\u003eFeaturing a 16-channel architecture with compression-style terminal blocks, the \u003cstrong\u003eMC-TAIH14\u003c\/strong\u003e enables clean termination of 4-20 mA field loops from transmitters measuring pressure, flow, level, and temperature. The board is built on Honeywell Size B mounting dimensions, providing physical layout compatibility for standard cabinet channel mounting alongside adjacent process termination assemblies.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eMC-TAIH14\u003c\/strong\u003e assembly (51305887-150) establishes reliable signal paths for real-time regulatory control loops and asset management functions. By interfacing high-level analog signals directly to system I\/O modules, it simplifies cabinet wiring, shields control room electronics from field-side interference, and provides access points for HART hand-held communicators and asset management software suites.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-density control environments, the board functions seamlessly across redundant and non-redundant system hardware layouts. Its structured terminal arrangement reduces field installation time and ensures long-term operational continuity across continuous process automation plants.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-Channel Capacity:\u003c\/strong\u003e Supports up to 16 individual high-level analog input channels for high-density field signal processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Protocol Support:\u003c\/strong\u003e Facilitates simultaneous transmission of standard 4-20 mA analog signals and HART digital communications for smart field instrument diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompression Terminal Blocks:\u003c\/strong\u003e Equipped with reliable compression-type (C) wiring terminals to simplify field instrument loop connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize B Mounting Form Factor:\u003c\/strong\u003e Designed in standard Honeywell Size B dimensions for uniform cabinet layout and channel mounting integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem IOP Compatibility:\u003c\/strong\u003e Integrates directly with Honeywell High Level Analog Input (HLAI) Processors via standard pre-fabricated I\/O interface cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Field Transmitter Interfacing:\u003c\/strong\u003e Terminating 4-20 mA HART-enabled pressure, temperature, differential pressure, and level transmitters in process control loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAsset Management Routing:\u003c\/strong\u003e Routing digital HART variables and field device diagnostic parameters to maintenance software systems without interrupting control loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDCS Cabinets Integration:\u003c\/strong\u003e Structuring high-density analog signal wiring within standard Honeywell TPS and Experion Process Knowledge System (PKS) enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExact Model \/ Order Code\u003c\/td\u003e\n\u003ctd\u003eMC-TAIH14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51305887-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction \/ Subtype\u003c\/td\u003e\n\u003ctd\u003eHigh Level Analog Input HART FTA (HLAIHART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eCompression Terminals (C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Size\u003c\/td\u003e\n\u003ctd\u003eSize B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC \/ HART Digital Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Process Manager (PM \/ APM \/ HPM \/ Experion)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface \/ Connection Point\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Compression Terminals\u003c\/td\u003e\n\u003ctd\u003eSecure connection points for 16 individual 4-20 mA HART analog input field loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Interface Connector\u003c\/td\u003e\n\u003ctd\u003eMulti-pin header for standard pre-fabricated cable connection to system I\/O Processors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Verification:\u003c\/strong\u003e Inspect the assembly part number (MC-TAIH14 \/ 51305887-150) to verify matching model specifications and physical integrity prior to mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap or latch the Size B assembly into the dedicated FTA mounting channel inside the cabinet enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e De-energize loop power and field-side circuits before wiring to prevent arc flash or electrical damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Loop Connection:\u003c\/strong\u003e Connect field instrument wiring to the compression terminals, adhering to polarity markings for each of the 16 analog channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Interface Cable:\u003c\/strong\u003e Connect the pre-fabricated Honeywell I\/O interface cable between the FTA board connector and the designated IOP slot in the cardfile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Bonding:\u003c\/strong\u003e Ensure field cable shields are properly grounded according to plant EMC and Honeywell system installation rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning Checks:\u003c\/strong\u003e Measure loop current on active channels, confirm analog-to-digital signal scaling at the controller, and test HART pass-through communication using a HART communicator.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667764539755,"sku":"MC-TAIH14 51305887-150","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/MC-TAIH14-51305887-150_003_1200x1200_9faa26c2-21c1-46ed-835e-5ca03524e45c.jpg?v=1787715853","url":"https:\/\/www.plcprotech.com\/products\/honeywell-mc-taih14-51305887-150-experion-pks-high-level-analog-input-hart-fta-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}