{"product_id":"honeywell-sc-pcmx01-51307195-175-rtu2020-controller-cpm","title":"Honeywell SC-PCMX01 51307195-175 RTU2020 Controller CPM","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell SC-PCMX01 51307195-175\u003c\/strong\u003e is a control processor module (CPM) designed for the RTU2020 Remote Terminal Unit system. Equipped with 28 mixed onboard I\/O, this module provides localized control and interface capabilities for remote automation tasks. The unit features a dual core ARM Cortex-A9 processor running at 667 MHz with a 32-bit data bus, supporting real-time data execution and onboard I\/O operations. Integrated HART functionality enables direct digital communication with connected field instrumentation without requiring external expansion hardware. Communication protocols including Modbus RTU\/ASCII\/TCP, DNP3, and HART-IP are supported across dual Ethernet and four serial ports for seamless integration into SCADA and Experion PKS environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt with a dual core ARM Cortex-A9 667 MHz processor, 128 MB RAM, and 32 MB Flash memory.\u003c\/li\u003e\n\u003cli\u003eIncludes 28 mixed onboard I\/O channels (8 AI, 2 AO, 10 DI, 6 DO, and 2 PI\/DI) with transient suppression on every channel.\u003c\/li\u003e\n\u003cli\u003eFeatures HART-enabled onboard I\/O with HART-IP support via Ethernet for remote field device management.\u003c\/li\u003e\n\u003cli\u003eEquipped with dual 10\/100BaseTx RJ45 Ethernet ports and four serial ports (2x RS232 RJ45 and 2x RS485 screw terminals).\u003c\/li\u003e\n\u003cli\u003eSupports Modbus RTU\/ASCII\/TCP and DNP3 protocols in master, slave, and outstation roles.\u003c\/li\u003e\n\u003cli\u003eDesigned with a built-in SD card slot supporting up to 32GB industry-standard SD cards for extended data logging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRemote oil and gas field automation, wellhead monitoring, and pipeline control.\u003c\/li\u003e\n\u003cli\u003eSCADA interface operations with Experion PKS or third-party monitoring systems.\u003c\/li\u003e\n\u003cli\u003eHART field device integration and remote asset management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC-PCMX01\u003c\/td\u003e\n\u003ctd\u003eRTU2020 controller CPM, 28 mixed onboard I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC-UCMX01\u003c\/td\u003e\n\u003ctd\u003e1 RTU2020 Non-redundant Controller with 28 mixed onboard I\/O (Includes 1 x SC-PCMX01 and 1 x SC-TCMX01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC-TCMX01\u003c\/td\u003e\n\u003ctd\u003eRTU2020 controller IOTA, 28 mixed I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSP-IHARTP\u003c\/td\u003e\n\u003ctd\u003eHART Protocol Enabler License\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSP-EBLDR1\u003c\/td\u003e\n\u003ctd\u003eRTU Builder software license\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eDual Core ARM Cortex-A9 Core (32 bit data bus) 667 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Memory (RAM)\u003c\/td\u003e\n\u003ctd\u003e128 Megabytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory (Flash)\u003c\/td\u003e\n\u003ctd\u003e32 Megabytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonvolatile Memory\u003c\/td\u003e\n\u003ctd\u003e4 Mbits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution Cycle Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-Time Clock Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e18 VDC to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power (With Field Power)\u003c\/td\u003e\n\u003ctd\u003eFull Load: 4.6W; Minimum: 1.6W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs (AI)\u003c\/td\u003e\n\u003ctd\u003e8 channels, 4-20mA \/ 1-5VDC, 16-bit resolution, accuracy +-0.1% at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs (AO)\u003c\/td\u003e\n\u003ctd\u003e2 channels, 4-20mA, 12-bit resolution, load resistance 50-600 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs (DI)\u003c\/td\u003e\n\u003ctd\u003e10 channels, 24VDC (+\/-10%), guaranteed ON at 12VDC, OFF at 4VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs (DO)\u003c\/td\u003e\n\u003ctd\u003e6 channels, 24VDC, 80mA max load per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Inputs (PI)\u003c\/td\u003e\n\u003ctd\u003e2 channels, 5-10V peak-to-peak, 0 to 10kHz frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2x 10\/100BaseTx RJ45 ports (isolated 1500V RMS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Ports\u003c\/td\u003e\n\u003ctd\u003e2x RS232 (RJ45), 2x RS485 (2-wire half-duplex screw terminal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +75 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail (TH35-7.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e184.0 mm x 98.5 mm x 140.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e700 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003e18-30 VDC Terminal Connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS232 Port A (RJ45)\u003c\/td\u003e\n\u003ctd\u003eTD, RD, CTS, RTS, CD, DTR, DSR\/RI, GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS232 Port B (RJ45)\u003c\/td\u003e\n\u003ctd\u003eTD, RD, CTS, RTS, CD, DTR, DSR\/RI, GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 Port C (Screw)\u003c\/td\u003e\n\u003ctd\u003eGND, 485+, 485-, Termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 Port D (Screw)\u003c\/td\u003e\n\u003ctd\u003eGND, 485+, 485-, Termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port 1 (RJ45)\u003c\/td\u003e\n\u003ctd\u003e10\/100BaseTx Network Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port 2 (RJ45)\u003c\/td\u003e\n\u003ctd\u003e10\/100BaseTx Network Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard I\/O Terminals\u003c\/td\u003e\n\u003ctd\u003e28 Mixed Onboard I\/O Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Installation:\u003c\/strong\u003e Mount the assembly securely onto standard TH35-7.5 DIN rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Wiring:\u003c\/strong\u003e Wire an 18 to 30 VDC external power supply to the designated power input terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Cabling:\u003c\/strong\u003e Connect shielded RJ45 Ethernet cables to the network ports; ensure separate subnets are configured when using both ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Wiring:\u003c\/strong\u003e Maintain proper termination (120 ohm) for RS485 2-wire half-duplex lines up to a maximum network length of 1200 meters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFlammability: UL 94V-0 materials\u003c\/li\u003e\n\u003cli\u003eEN61010-1:1993; CE\u003c\/li\u003e\n\u003cli\u003eEN61326-1; CE\u003c\/li\u003e\n\u003cli\u003eEN61326\u003c\/li\u003e\n\u003cli\u003eCE Certificate\u003c\/li\u003e\n\u003cli\u003eANSI\/ISA S71.04 Class G2 (Standard)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667763163499,"sku":"SC-PCMX01 51307195-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-sc-pcmx01-51307195-175-control-module-efy0qllh5cp_92abfedf-be87-41dd-aa18-9f243e29492e.jpg?v=1765501743","url":"https:\/\/www.plcprotech.com\/products\/honeywell-sc-pcmx01-51307195-175-rtu2020-controller-cpm","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}