{"product_id":"honeywell-sc-ucmx01-51307195-175-experion-pks-controller-module","title":"Honeywell SC-UCMX01 51307195-175 RTU2020 Non-Redundant Controller Kit with 28 Onboard I\/O","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell SC-UCMX01 51307195-175\u003c\/strong\u003e is a complete remote terminal unit controller kit in the \u003cstrong\u003eRTU2020\u003c\/strong\u003e family, engineered for demanding remote automation, field data acquisition, and process monitoring applications. The package consists of a Control Processor Module (CPM) and a matching Input Output Termination Assembly (IOTA) carrying part number \u003cstrong\u003e51307195-175\u003c\/strong\u003e. Driven by a dual-core ARM Cortex-A9 32-bit processor operating at 667 MHz, this non-redundant assembly combines high-efficiency execution with ultra-low power consumption, drawing as little as 1.8 W typical under standard operating conditions.\u003c\/p\u003e\n\u003cp\u003eThis controller features 28 mixed onboard I\/O channels, including 8 HART-enabled Analog Inputs and 2 HART-enabled Analog Outputs, eliminating the need for external HART signal converters. The onboard dynamic memory (128 MB RAM) and non-volatile flash memory (32 MB Flash plus 4 Mbit retentive storage) ensure stable data handling, execution cycle times under 100 ms, and retentive data preservation for over 20 years without battery reliance. Datalogging capabilities are built-in, supporting local Flash storage or expansion via an onboard SD card slot up to 32 GB.\u003c\/p\u003e\n\u003cp\u003eCommunication versatility is central to the architecture of the \u003cstrong\u003eHoneywell SC-UCMX01\u003c\/strong\u003e. The unit is built with dual 10\/100BaseTx Ethernet ports supporting auto-crossover and 1500 V RMS isolation, alongside two RS232 ports and two 2-wire RS485 ports. Supported industrial communication protocols include Modbus TCP, Modbus RTU\/ASCII (Master\/Slave), DNP3 TCP (Outstation\/Slave Level 3+), and HART-IP Version 7 for instrument asset management via Field Device Manager. Designed for harsh field installations, all I\/O and communication interfaces feature integrated 600 W transient voltage suppression.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete Integrated Assembly:\u003c\/strong\u003e Combines the Control Processor Module (CPM) and passive Input Output Termination Assembly (IOTA) under single ordering model SC-UCMX01.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Power Architecture:\u003c\/strong\u003e Delivers high computing performance with a typical power draw of 1.8 W (1.6 W minimum to 4.6 W full field load).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Onboard I\/O:\u003c\/strong\u003e Provides 28 mixed channels onboard, including 8 Analog Inputs, 2 Analog Outputs, 10 Digital Inputs, 6 Digital Outputs, and 2 High-Speed Pulse\/Digital Inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated HART Capability:\u003c\/strong\u003e Supports HART protocol natively on onboard analog channels for local program access, diagnostic alarms, and HART-IP remote asset management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Industrial Operating Range:\u003c\/strong\u003e Operates reliably in ambient temperatures from -40 degC to 75 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Serial and Ethernet Connectivity:\u003c\/strong\u003e Equipped with 2 Ethernet RJ45 ports, 2 RS232 serial ports, and 2 RS485 isolated\/terminated ports supporting Modbus and DNP3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Surge Protection:\u003c\/strong\u003e Features 600 W peak pulse power transient voltage suppression on all I\/O channels and serial\/Ethernet communication ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Datalogging \u0026amp; Events:\u003c\/strong\u003e Holds up to 80,000 DNP3 events in onboard Flash memory or up to 500,000 events on an optional SD card (up to 32 GB supported).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil \u0026amp; Gas Wellhead Automation:\u003c\/strong\u003e Remote monitoring and control of pressure, temperature, and multi-variable HART transmitters at remote well pads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePipeline Monitoring \u0026amp; Flow Measurement:\u003c\/strong\u003e Real-time data logging and liquid\/gas flow computations using AGA 3, AGA 7, AGA 8, and API 11.1 function block libraries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater \u0026amp; Wastewater Remote Facilities:\u003c\/strong\u003e Supervisory control and data acquisition for pump stations, lift stations, and remote reservoir monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubstation \u0026amp; Remote Infrastructure:\u003c\/strong\u003e Integration with central SCADA networks via DNP3 TCP Level 3+ or Modbus communication links.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCapability Status\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC-UCMX01\u003c\/td\u003e\n\u003ctd\u003eRTU2020 Non-Redundant Controller Kit with 28 Onboard I\/O\u003c\/td\u003e\n\u003ctd\u003eStandard Complete Assembly (CPM + IOTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e51307195-175\u003c\/td\u003e\n\u003ctd\u003eAssembly Part Number for CPM and IOTA hardware base\u003c\/td\u003e\n\u003ctd\u003eComponent Hardware Identifiers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSP-IHARTP\u003c\/td\u003e\n\u003ctd\u003eHART Protocol Enabler License\u003c\/td\u003e\n\u003ctd\u003eOptional License (Required for HART digital access)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSP-EBLDR1\u003c\/td\u003e\n\u003ctd\u003eRTU Builder Client License\u003c\/td\u003e\n\u003ctd\u003eOptional Client Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSP-MCALC1\u003c\/td\u003e\n\u003ctd\u003eMetering Calculation Library Site License\u003c\/td\u003e\n\u003ctd\u003eOptional Site Calculation License\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eSC-UCMX01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Part Number\u003c\/td\u003e\n\u003ctd\u003e51307195-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eRTU2020 Remote Terminal Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e190 mm x 99 mm x 141 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e700 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (TH35-7.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eProcessor \u0026amp; Memory\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eDual Core ARM Cortex-A9 (32-bit data bus), 667 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Memory (RAM)\u003c\/td\u003e\n\u003ctd\u003e128 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory (Flash)\u003c\/td\u003e\n\u003ctd\u003e32 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-volatile Retentive Memory\u003c\/td\u003e\n\u003ctd\u003e4 Mbits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-volatile Memory Retention\u003c\/td\u003e\n\u003ctd\u003e20+ years (without battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution Cycle Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-time Clock Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Synchronization\u003c\/td\u003e\n\u003ctd\u003eSimple Network Time Protocol (SNTP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Card Slot\u003c\/td\u003e\n\u003ctd\u003eSD Card (up to 32 GB, Class 6 \/ Class 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003ePower Requirements\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e18 VDC to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Power Consumption\u003c\/td\u003e\n\u003ctd\u003e1.6 W (24 VDC, 1 active Ethernet port, no active serial ports, no field load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Power Consumption\u003c\/td\u003e\n\u003ctd\u003e1.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Power Consumption\u003c\/td\u003e\n\u003ctd\u003e2.8 W (24 VDC, excluding field power) \/ 4.6 W (30 VDC, full field load included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eOnboard Input \/ Output (28 Channels)\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs (AI)\u003c\/td\u003e\n\u003ctd\u003e8 channels, 4-20 mA or 1-5 VDC (software configurable), single-ended, 16-bit A\/D, +-0.1% accuracy at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs (AO)\u003c\/td\u003e\n\u003ctd\u003e2 channels, 4-20 mA source type, 12-bit D\/A, +-0.2% accuracy at 25 degC, load 50-600 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs (DI)\u003c\/td\u003e\n\u003ctd\u003e10 channels, sink type (dry contact), 24 VDC nominal, guaranteed ON \u0026gt;= 12 VDC, OFF \u0026lt;= 4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs (DO)\u003c\/td\u003e\n\u003ctd\u003e6 channels, sink type (voltage-free), 24 VDC, max 80 mA load per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Inputs (PI)\u003c\/td\u003e\n\u003ctd\u003e2 channels, 0 to 10 kHz, 5-10 V peak-to-peak, sink type (configurable as Pulse or Digital Input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Protection\u003c\/td\u003e\n\u003ctd\u003eShort circuit protection and 600 W transient voltage suppression on all channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCommunication\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 10\/100BaseTx ports, shielded RJ45, auto-detecting, auto-crossover, 1500 V RMS isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Ports\u003c\/td\u003e\n\u003ctd\u003e2 x RS232 (RJ45, full duplex, up to 115,200 bps), 2 x RS485 (screw terminals, 2-wire half-duplex, 120 ohm termination)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus TCP, DNP3 TCP (Slave Level 3+), HART-IP Version 7, TCP\/IP, ARP, UDP, ICMP, DHCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus RTU Master\/Slave, Modbus ASCII Master\/Slave, DNP3 Slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol Concurrent Links\u003c\/td\u003e\n\u003ctd\u003eUp to 64 concurrent Ethernet connections; multi-master Modbus and DNP3 monitoring supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental \u0026amp; Environmental Ratings\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 75 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to 85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlammability Rating\u003c\/td\u003e\n\u003ctd\u003eUL 94V-0 compliant materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2-6: 1.0 g acceleration (10–150 Hz), 0.5 g acceleration (150–2000 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosive Atmosphere\u003c\/td\u003e\n\u003ctd\u003eANSI\/ISA S71.04 Class G2 (Standard), Class G3 (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections \/ Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSignal Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003ctd\u003e18 VDC to 30 VDC main power feed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports (qty 2)\u003c\/td\u003e\n\u003ctd\u003eShielded RJ45\u003c\/td\u003e\n\u003ctd\u003e10\/100BaseTx Ethernet ports (Port 1 \u0026amp; Port 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS232 Ports (qty 2)\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003ctd\u003eFull duplex serial (TD, RD, CTS, RTS, CD, DTR, DSR\/RI, GND)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS485 Ports (qty 2)\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003ctd\u003e2-wire half duplex (485+, 485-, GND, termination, chassis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard I\/O Terminals\u003c\/td\u003e\n\u003ctd\u003eTerminal Block Assembly\u003c\/td\u003e\n\u003ctd\u003eConnection points for 8 AI, 2 AO, 10 DI, 6 DO, and 2 PI channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Slot\u003c\/td\u003e\n\u003ctd\u003eSD Slot\u003c\/td\u003e\n\u003ctd\u003eFits standard SD memory card up to 32 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Inspection:\u003c\/strong\u003e Verify that the hardware assembly (CPM unit mounted on IOTA 51307195-175) is free from physical damage and that all terminal blocks are properly seated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Snap the assembly securely onto a standard 35 mm DIN rail (TH35-7.5) inside an appropriately rated enclosure matching field hazardous location requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Wiring:\u003c\/strong\u003e Connect a regulated 18–30 VDC power supply to the main power terminal block. Ensure polarity is correct before applying power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Channel Wiring:\u003c\/strong\u003e Connect field instruments according to signal type:\n\u003cul\u003e\n\u003cli\u003eConnect 4-20 mA \/ 1-5 VDC sensors to Analog Input terminals.\u003c\/li\u003e\n\u003cli\u003eConnect 24 VDC dry contacts to Digital Inputs.\u003c\/li\u003e\n\u003cli\u003eVerify that Digital Output load currents do not exceed 80 mA per channel at 24 VDC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e Terminate field cable shields directly at the designated grounding bar or chassis ground terminals to ensure effective transient voltage protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Connectivity:\u003c\/strong\u003e Attach shielded CAT5e or CAT6 Ethernet cables to the RJ45 network ports for connection to local HMIs, radios, or SCADA switches.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eConfiguration \/ Commissioning \/ Replacement\u003c\/h3\u003e\n\u003ch4\u003eConfiguration Guidelines\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUse \u003cstrong\u003eRTU Builder\u003c\/strong\u003e software installed on a compatible Windows PC (Windows 7 Pro SP1 or Windows Server 2008 R2) to create and download IEC 61131-3 logic programs (Ladder Diagram, Function Block Diagram, Structured Text, Instruction List, or Sequential Function Chart).\u003c\/li\u003e\n\u003cli\u003eConfigure communication parameters (IP addresses, Modbus register maps, DNP3 point tables, serial baud rates) within RTU Builder.\u003c\/li\u003e\n\u003cli\u003eIf HART instrument access is required, ensure the \u003cstrong\u003eSP-IHARTP\u003c\/strong\u003e license is applied to enable pass-through data reading and remote asset management via HART-IP.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommissioning Recommendations\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePerform a warm or cold reboot test via RTU Builder to confirm project persistence in Flash memory.\u003c\/li\u003e\n\u003cli\u003eVerify real-time signal values across all 28 onboard I\/O channels using online monitoring in RTU Builder.\u003c\/li\u003e\n\u003cli\u003eValidate time synchronization performance using an SNTP server on the local network.\u003c\/li\u003e\n\u003cli\u003eVerify communication links with the central SCADA system over Modbus TCP or DNP3 TCP.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eReplacement Recommendations\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBefore removing an active module, upload and back up the current IEC 61131-3 project, configuration files, and datalog files using RTU Builder.\u003c\/li\u003e\n\u003cli\u003eDisconnect the main power input block prior to unseating wires or dismounting the hardware.\u003c\/li\u003e\n\u003cli\u003eTransfer field wiring connectors directly to the replacement unit to maintain pin integrity.\u003c\/li\u003e\n\u003cli\u003eDownload the saved project and restore parameters to the replacement \u003cstrong\u003eSC-UCMX01\u003c\/strong\u003e controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Certified under EN61010-1:1993, EN61326-1, and EN61326.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFM Approval:\u003c\/strong\u003e Nonincendive for Class I, Division 2, Groups A, B, C, D (T4); AEx nA IIC T4 for Class I, Zone 2 (-40 degC \u0026lt;= Ta \u0026lt;= 75 degC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA Certified:\u003c\/strong\u003e Nonincendive for Class I, Division 2, Groups A, B, C, D (T4); Ex nA IIC T4 for Class I, Zone 2 (-40 degC \u0026lt;= Ta \u0026lt;= 75 degC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX Certification:\u003c\/strong\u003e II 3 G Ex nA IIC T4 Gc (-40 degC \u0026lt;= Ta \u0026lt;= +75 degC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Standards:\u003c\/strong\u003e ANSI\/ISA S71.04 Class G2 Airborne Contaminants (Standard); Class G3 option available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Materials:\u003c\/strong\u003e UL 94V-0 flame-retardant rated.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667763261803,"sku":"SC-UCMX01 51307195-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/SC-UCMX01-51307195-175_003_1200x1200_7ae1a1f1-047f-4071-99bd-098bfe82a2d8.jpg?v=1788268738","url":"https:\/\/www.plcprotech.com\/products\/honeywell-sc-ucmx01-51307195-175-experion-pks-controller-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}