{"product_id":"honeywell-sps6061-lf-fc-psuni2424-safety-manager-power-supply-module","title":"Honeywell SPS6061-LF FC-PSUNI2424 Safety Manager Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell SPS6061-LF FC-PSUNI2424\u003c\/strong\u003e is a switched-mode AC to DC \u003cstrong\u003epower supply module\u003c\/strong\u003e designed for connection to industrial installations for use in process and safety controllers. The \u003cstrong\u003eSPS6061-LF FC-PSUNI2424\u003c\/strong\u003e delivers a 600W nominal power output with high efficiency, accepting a wide AC input range between 100VAC and 240VAC and converting it to a regulated 24V DC output. Engineered with dual independent over-voltage protection supporting IEC 61508 architectural constraints, the device provides SIL3-certified over-voltage protection that guarantees output levels remain below 31VDC. The power supply features an integrated power switch and an isolated solid-state Opto-FET alarm contact for real-time module status monitoring.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual built-in over-voltage protection supporting SIL3 applications according to IEC 61508.\u003c\/li\u003e\n\u003cli\u003eIntegrated ON\/OFF power switch combined with isolated AC and DC power connectors enabling on-line replacement in a live system.\u003c\/li\u003e\n\u003cli\u003eSupports parallel operation of up to eight units to deliver higher output currents with load sharing within 10% difference at full load.\u003c\/li\u003e\n\u003cli\u003eWide operating temperature capability from -40 degC to 70 degC with controlled fan speed reduction.\u003c\/li\u003e\n\u003cli\u003eDC under-voltage protection (\u0026lt;23.5V) and AC under-voltage protection (\u0026lt;80V) alarms.\u003c\/li\u003e\n\u003cli\u003eGreater than 50ms hold-up time and 50A\/200ms peak output current capability for clearing downstream fuses.\u003c\/li\u003e\n\u003cli\u003eContinuous protection against short-circuiting and overload via an electronic current limiter.\u003c\/li\u003e\n\u003cli\u003eInrush current limited to under 60A, supporting 10A type C circuit breakers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcess and safety controller power distribution systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial SIL3 safety instrumented systems requiring SELV 24VDC power supply architecture.\u003c\/li\u003e\n\u003cli\u003eField instrumentation loops utilizing HART communication protocol.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType Number\u003c\/td\u003e\n\u003ctd\u003eFC-PSUNI2424\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e25.7V no load; 25.1V with 24A static load; 24.5-26.5V with 24A dynamic load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0-24A continuously; 50A for 200ms typical for clearing fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-120 \/ 220-240VAC nominal (Operational between 85 - 265VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e115VAC: 712W; 230VAC: 691W typical (85VAC: 750W; 220VAC: 720W maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Efficiency\u003c\/td\u003e\n\u003ctd\u003e100VAC: 80% @ 6A and 84.5% @ 12-24A; 230VAC: 82% @ 6A and 87% @ 12-24A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e100VAC: \u0026gt;0.99 @ 6-24A; 230VAC: \u0026gt;0.88 @ 6A and 0.98 @ 24A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency Range\u003c\/td\u003e\n\u003ctd\u003e45-66Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e115VAC: 6.2A; 230VAC: 3.1A (at rated DC output load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Fusing\u003c\/td\u003e\n\u003ctd\u003e10A fuse for each AC leg line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Protection\u003c\/td\u003e\n\u003ctd\u003eFuse: 10A class CC or MCB: 10-13A type C (EN60898-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-up Time\u003c\/td\u003e\n\u003ctd\u003e50ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple\u003c\/td\u003e\n\u003ctd\u003e20-40mV typical (HART compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;100mV LL and \u0026lt;700mV LE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Sharing\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10% difference at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronic Current Limiter\u003c\/td\u003e\n\u003ctd\u003e34A typical (27A-42A) after 200ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDerating Output Current\u003c\/td\u003e\n\u003ctd\u003eSingle operation: 24A with -0.6A\/degC above 60degC up to 2000m altitude; Parallel operation: 24A with -0.6A\/degC above 50degC up to 2000m altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output Type\u003c\/td\u003e\n\u003ctd\u003eSolid-state output (Opto-FET) isolated up to 500VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Activation\u003c\/td\u003e\n\u003ctd\u003eActivated when power supply status is okay (FAN speed okay and output voltage \u0026gt;23.5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Nominal Voltage\u003c\/td\u003e\n\u003ctd\u003e31V maximum (33V TVS protected inside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Nominal Current\u003c\/td\u003e\n\u003ctd\u003e40mA maximum non inductive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.2V at 7mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Short Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eYes (Trips within 1 second at 0.5A - self restoring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFAN Speed\u003c\/td\u003e\n\u003ctd\u003e0% below -10degC, 50% above -10degC, 100% above 80-85degC heatsink temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Input to Output\u003c\/td\u003e\n\u003ctd\u003e3750VAC\/1min (8mm creepage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Input to Case\u003c\/td\u003e\n\u003ctd\u003e2210VAC\/1min; Transient limited by 3000V spark gap and 300VAC varistor in series; 100% tested at 2300VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Output to Case\u003c\/td\u003e\n\u003ctd\u003e1500VDC\/1min; Transient limited by 320VAC varistor; \u0026lt;50M Ohm at 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40degC to 85degC (Keep below 40degC for long term storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40degC to 70degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Temperature Change\u003c\/td\u003e\n\u003ctd\u003e3degC\/minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH non-condensing (Derating RH above 40degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003ePD2 maximum (IEC60664-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e0-2000m above sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e370 x 159 x 67.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Mating Connector\u003c\/td\u003e\n\u003ctd\u003ePX0597, BULGIN C15 IEC (Cable: 80042 EcoFlex, 3x 16AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Mating Connector\u003c\/td\u003e\n\u003ctd\u003e1967456 PC 16\/2-stf-10,16, Phoenix Contact (Cable: HV8-55-0 AND HV8-55-2, PowerFlex 1000, 8AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Mating Connector\u003c\/td\u003e\n\u003ctd\u003e1827703 MC 1,5\/2-STF-3,81 (20-24AWG Alarm wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Orientation:\u003c\/strong\u003e Mount the unit vertically or horizontally. Vertical mounting is preferred for optimal convection cooling, with the power and fan input facing downwards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlade Spacing:\u003c\/strong\u003e Maintain an absolute minimum spacing of 12.5 mm (0.5 in) between two blade-mounted units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Switch Operation:\u003c\/strong\u003e Turn off the power switch before disconnecting the unit. After switching the unit OFF, wait at least 30 seconds before switching it ON again to avoid permanent damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Circuit Protection:\u003c\/strong\u003e Each power supply AC input requires a double pole external 10A circuit breaker (type C) or 10A class CC fuse in series for electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude Derating:\u003c\/strong\u003e Ensure output load derating starts 10degC earlier when DC outputs are configured in parallel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecUL (60950)\u003c\/li\u003e\n\u003cli\u003eSELV certified according to EN60950\u003c\/li\u003e\n\u003cli\u003eSIL3 certified for over-voltage protection (IEC 61508)\u003c\/li\u003e\n\u003cli\u003eEMC Standards: EN61131-2, EN50130-4, EN61000-6-7\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668037464427,"sku":"SPS6061-LF FC-PSUNI2424","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-sps6061-lf-fc-psuni2424-power-supply-mxsk0zafdkq_0863024f-c1be-40bd-bd50-a05fd95abe5c.jpg?v=1765505398","url":"https:\/\/www.plcprotech.com\/products\/honeywell-sps6061-lf-fc-psuni2424-safety-manager-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}