{"product_id":"honeywell-tc-fpdxx2-uncoated-series-a-power-supply","title":"Honeywell TC-FPDXX2 Uncoated Series-A Power Supply","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-FPDXX2\u003c\/strong\u003e is an uncoated Series-A non-redundant power supply module designed to deliver reliable DC operating power to modules installed within an Experion LX \/ Experion LS Chassis Series-A platform. Mounted directly onto the left side of the chassis backplane without consuming an I\/O slot, the \u003cstrong\u003eTC-FPDXX2\u003c\/strong\u003e converts a nominal 24 VDC input into four regulated backplane output voltages—1.2 VDC, 3.3 VDC, 5.1 VDC, and 24.0 VDC—providing up to 70 W total power output to support controller, network, and I\/O module operations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-redundant chassis-side mounting designed to power backplane modules without consuming an I\/O slot position.\u003c\/li\u003e\n\u003cli\u003eWide DC input range from 19.2 to 32 VDC with tolerance for temporary drops down to 16 VDC during motor starting conditions.\u003c\/li\u003e\n\u003cli\u003eQuad-voltage DC backplane output supplying 1.2 VDC, 3.3 VDC, 5.1 VDC, and 24.0 VDC.\u003c\/li\u003e\n\u003cli\u003eHigh total power output capability delivering up to 70 W at 60 degC.\u003c\/li\u003e\n\u003cli\u003eIntegrated non-replaceable soldered fuse protection for enhanced short-circuit and fire hazard prevention.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExperion LS and C200E process control chassis power distribution.\u003c\/li\u003e\n\u003cli\u003eDistributed Control Systems (DCS) operating in 24 VDC plant power environments.\u003c\/li\u003e\n\u003cli\u003eRemote I\/O chassis assemblies requiring internal backplane logic power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-FPDXX2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eUncoated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19.2 to 32 VDC (Input may drop to 16 VDC for max 2 minutes\/hour)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e100 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Power Output Maximum\u003c\/td\u003e\n\u003ctd\u003e70 W @ 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Output Current, 1.2 VDC\u003c\/td\u003e\n\u003ctd\u003e1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Output Current, 3.3 VDC\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Output Current, 5.1 VDC\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Output Current, 24.0 VDC\u003c\/td\u003e\n\u003ctd\u003e2.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Protection\u003c\/td\u003e\n\u003ctd\u003eNon-replaceable fuse soldered in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Gauge\u003c\/td\u003e\n\u003ctd\u003e#14 AWG (1.4 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Location\u003c\/td\u003e\n\u003ctd\u003eLeft side of chassis (does not consume a slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC (32 to 140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC (-40 to 185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x D x H)\u003c\/td\u003e\n\u003ctd\u003e11.2 x 14.5 x 14.0 cm (4.41 x 5.71 x 5.51 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.1 kg (2.5 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Position:\u003c\/strong\u003e Install directly onto the left end of the Series-A chassis backplane. Ensure the power module interlocks properly with the chassis structure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Requirements:\u003c\/strong\u003e Connect incoming DC power using #14 AWG (1.4 mm) wire to match terminal specifications. Maintain correct input polarity during installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Load Calculation:\u003c\/strong\u003e Calculate total power consumption of all populated backplane modules to ensure combined output power on 1.2 V, 3.3 V, 5.1 V, and 24.0 V rails does not exceed the 70 W limit at 60 degC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal \u0026amp; Clearance:\u003c\/strong\u003e Maintain adequate vertical and horizontal clearance around the chassis assembly to allow proper convective cooling and prevent ambient temperatures from exceeding 60 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUL 508 Industrial Control Equipment\u003c\/li\u003e\n\u003cli\u003eClass I, Div 2, Groups A, B, C \u0026amp; D Hazardous and Ordinary locations\u003c\/li\u003e\n\u003cli\u003e89\/336\/EEC, EMC Directive (EN 50081-2 Emissions, EN 50082-2 Immunity)\u003c\/li\u003e\n\u003cli\u003eC-Tick (Australian Radiocommunications Act)\u003c\/li\u003e\n\u003cli\u003eCE-Mark Approval\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705321451883,"sku":"TC-FPDXX2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/TC-FPDXX2-yo1pswumjiu_034ec8c8-ba9c-43ff-b4d6-1d071105a0e4.jpg?v=1766639777","url":"https:\/\/www.plcprotech.com\/products\/honeywell-tc-fpdxx2-uncoated-series-a-power-supply","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}