{"product_id":"honeywell-tc-iah061-experion-analog-input-module","title":"Honeywell TC-IAH061 Experion Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for precise process variable monitoring, the \u003cstrong\u003eHoneywell TC-IAH061\u003c\/strong\u003e functions as a high-density analog input module within the Experion control platform. This module features six galvanically isolated channels designed to interface directly with field-side transmitters while maintaining signal integrity and protecting the control-side system electronics from ground loops and electrical noise.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eTC-IAH061\u003c\/strong\u003e is designed for high-availability systems, incorporating built-in open-circuit detection mechanisms that dynamically respond to loop failures with configurable upscale or zero-scale fault behaviors. With a rapid channel update rate and robust radio frequency interference (RFI) shielding, this input module ensures dependable signal acquisition under demanding thermal and electrical conditions inside industrial control enclosures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSix fully galvanically isolated input channels for enhanced electrical isolation between field circuits and system logic.\u003c\/li\u003e\n  \u003cli\u003eIntegrated open-circuit diagnostic capabilities with upscale reaction for voltage configurations and zero-scale reaction for current loops.\u003c\/li\u003e\n  \u003cli\u003eFast channel conversion rates with a 25 ms module update rate across all active inputs.\u003c\/li\u003e\n  \u003cli\u003eHigh-performance RF shielding to protect input measurements against electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eLow-power dissipation architecture to minimize heat generation within compact marshalling cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOil and gas refinery process variable tracking\u003c\/li\u003e\n  \u003cli\u003eChemical processing plant automation and safety monitoring\u003c\/li\u003e\n  \u003cli\u003ePower generation plant turbine and boiler instrumentation\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment distribution monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003e\u003ctd\u003eParameter\u003c\/td\u003e\u003c\/strong\u003e\n      \u003cstrong\u003e\u003ctd\u003eSpecification\u003c\/td\u003e\u003c\/strong\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003eTC-IAH061\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003eExperion\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNumber of Channels\u003c\/td\u003e\n      \u003ctd\u003e6 galvanically isolated channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOpen Circuit Detection\u003c\/td\u003e\n      \u003ctd\u003eUpscale reading (Voltage); Zero scale reading (Current)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTypical OC Detection Time\u003c\/td\u003e\n      \u003ctd\u003e5 seconds (Voltage); 1 second (Current)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eChannel Bandwidth\u003c\/td\u003e\n      \u003ctd\u003e0 to 15 Hz (-3 dB)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRFI Immunity\u003c\/td\u003e\n      \u003ctd\u003eError of less than 2.0% of range at 10 V\/m (27 to 1000 MHz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Dissipation\u003c\/td\u003e\n      \u003ctd\u003e4.3 W maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCompatible Terminal Block\u003c\/td\u003e\n      \u003ctd\u003eTC-TBNH (20-position terminal block)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Update Rate\u003c\/td\u003e\n      \u003ctd\u003e25 ms (all channels)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd\u003e2.5 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003e\u003ctd\u003eInterface Type\u003c\/td\u003e\u003c\/strong\u003e\n      \u003cstrong\u003e\u003ctd\u003eSpecification \/ Mapping\u003c\/td\u003e\u003c\/strong\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnection Terminal Block\u003c\/td\u003e\n      \u003ctd\u003eTC-TBNH\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTerminal Positions\u003c\/td\u003e\n      \u003ctd\u003e20-position screw terminal connection block\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that all system power is completely isolated before attempting to insert or extract the \u003cstrong\u003eTC-IAH061\u003c\/strong\u003e module from the chassis. Align the module housing carefully with the card guides and slide it firmly into the slot until the connectors are fully seated. Secure the 20-position TC-TBNH terminal block to the front interface. To ensure compliance with RFI immunity specifications, all analog signal wiring must use shielded twisted-pair cabling, with shields properly terminated at the cabinet entry ground point.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705315684715,"sku":"TC-IAH061","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/TC-IAH061-ynj0jlswlof_7f0d5085-8368-4307-80e9-9c9c3508e4a5.jpg?v=1766639632","url":"https:\/\/www.plcprotech.com\/products\/honeywell-tc-iah061-experion-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}