{"product_id":"honeywell-tc-ioli01-51403427-125-plantscape-experion-c200-i-o-link-interface-module","title":"Honeywell TC-IOLI01 51403427-125 PlantScape Experion C200 I\/O Link Interface Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-IOLI01\u003c\/strong\u003e (Part Number \u003cstrong\u003e51403427-125\u003c\/strong\u003e) is an I\/O Link Interface Module (I\/O LIM) designed for integration within \u003cstrong\u003eHoneywell PlantScape\u003c\/strong\u003e and \u003cstrong\u003eExperion PKS C200\u003c\/strong\u003e process control architecture. It acts as a dedicated communication link interface module, establishing deterministic data transfer between the C200 Control Processor chassis backplane and distributed I\/O chassis racks or field I\/O termination networks over the dedicated I\/O Link bus.\u003c\/p\u003e\n\u003cp\u003eAs a core communication unit within the C200 controller infrastructure, the \u003cstrong\u003eTC-IOLI01\u003c\/strong\u003e manages real-time I\/O scanning, signal buffering, and high-speed data exchange to ensure consistent, low-latency control loop performance. The module routes multi-rail DC power directly from the backplane to drive internal communications logic and line transceiver circuits.\u003c\/p\u003e\n\u003cp\u003eBuilt for harsh industrial process environments, the hardware features integrated protection, multi-jurisdictional agency certifications for class-divided hazardous locations, and standard chassis mounting compatibility. The module enables seamless system expansion, allowing process engineers to integrate both local and remote I\/O subsystems into a single unified control network.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated I\/O Bus Interface:\u003c\/strong\u003e Facilitates high-speed communication between the Experion C200 Control Processor and connected I\/O racks over the Honeywell I\/O Link network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeterministic Signal Routing:\u003c\/strong\u003e Delivers real-time I\/O scanning and low-jitter data throughput for critical process loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Rail Backplane Powering:\u003c\/strong\u003e Utilizes internal backplane power rails (1.2 VDC, 3.3 VDC, 5.1 VDC, and 24 VDC) for internal processing and communication interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Environment Compliance:\u003c\/strong\u003e Certified for Class I, Division 2 hazardous locations (Groups A, B, C, D with Temperature Code T4A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis-Integrated Design:\u003c\/strong\u003e Standard slot-mounting footprint engineered for installation in C200 control chassis racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlantScape \u0026amp; Experion PKS C200 Systems:\u003c\/strong\u003e Interconnects C200 controllers with distributed I\/O chassis and field termination assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed Process Control:\u003c\/strong\u003e Establishes high-speed I\/O communication links across process control cabinets in chemical, refining, and manufacturing facilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy Control Network Migration:\u003c\/strong\u003e Serves as a vital communication bridge for expanding or maintaining existing Honeywell C200 control racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eTC-IOLI01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e51403427-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevision\u003c\/td\u003e\n\u003ctd\u003eHardware Rev A \/ Firmware Rev A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eI\/O Link Interface Module (I\/O LIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget System Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell PlantScape \/ Experion PKS C200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eElectrical Ratings\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eCurrent Consumption\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Input @ 1.2 VDC\u003c\/td\u003e\n\u003ctd\u003e0.004 A (4 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Input @ 3.3 VDC\u003c\/td\u003e\n\u003ctd\u003e0.31 A (310 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Input @ 5.1 VDC\u003c\/td\u003e\n\u003ctd\u003e0.4 A (400 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Input @ 24 VDC\u003c\/td\u003e\n\u003ctd\u003e0.073 A (73 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Installation Verification:\u003c\/strong\u003e Confirm that the module part number (\u003cstrong\u003e51403427-125\u003c\/strong\u003e) matches system drawings. Inspect backplane edge connectors for damage or contamination prior to insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Ensure the target C200 chassis power supply is completely de-energized before inserting or removing the module to prevent electrical transients or backplane bus disruption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Mounting:\u003c\/strong\u003e Align the module card edges with the chassis slot guides. Slide the module firmly into the slot until the backplane connector is fully seated, then secure the chassis retaining screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Link Cabling:\u003c\/strong\u003e Connect the approved Honeywell I\/O Link coaxial or twinaxial cables to the module ports. Ensure cables are strain-relieved and proper line termination resistors are installed at both ends of the segment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e Maintain clean cabinet ground connections. Ensure coaxial cable shields are landed according to Honeywell technical publication TC-DCSX21 guidelines to mitigate EMI\/RFI interference.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCommissioning and Replacement\u003c\/h3\u003e\n\u003ch3\u003eCommissioning Recommendations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage Check:\u003c\/strong\u003e Verify chassis backplane voltages (+1.2 VDC, +3.3 VDC, +5.1 VDC, +24 VDC) are within nominal limits prior to initializing communication loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLink Diagnostics:\u003c\/strong\u003e Monitor controller system status logs to verify that the I\/O LIM is recognized on the I\/O Link network without reporting frame errors or bus retry flags.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eReplacement Considerations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eParameter Backup:\u003c\/strong\u003e Backup system configuration data in Experion Builder before replacing an active interface module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Matching:\u003c\/strong\u003e Ensure the replacement module hardware and firmware revision match the target system configuration (Firmware Rev A) to maintain predictable I\/O timing and network behavior.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Listed:\u003c\/strong\u003e Industrial Control Equipment 48RL (UL Listed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA Certified:\u003c\/strong\u003e Certified for hazardous locations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFM Approved:\u003c\/strong\u003e Factory Mutual Approved\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e European Conformity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRCM \/ C-Tick:\u003c\/strong\u003e N314\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Locations Rating:\u003c\/strong\u003e Class I, Division 2, Groups A, B, C, D; Temp Code T4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference Documentation:\u003c\/strong\u003e Technical Publication TC-DCSX21\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668012003691,"sku":"TC-IOLI01 51403427-125","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/TC-IOLI01-51403427-125_003_1200x1200_04003502-f3b3-4e04-b08e-0bea5fa2725b.jpg?v=1786961241","url":"https:\/\/www.plcprotech.com\/products\/honeywell-tc-ioli01-51403427-125-plantscape-experion-c200-i-o-link-interface-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}