{"product_id":"honeywell-tk-fpdxx2-chassis-series-a-standard-power-supply-module","title":"Honeywell TK-FPDXX2 Chassis Series-A Standard Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell TK-FPDXX2\u003c\/strong\u003e is a conformal-coated, standard (non-redundant) power supply module designed for Experion Chassis Series-A (CIOM-A) systems. It slides directly onto the left side of the chassis to supply DC power to all installed modules via the backplane without consuming a standard chassis slot position. Featuring a conformal coating, the \u003cstrong\u003eTK-FPDXX2\u003c\/strong\u003e is designed to withstand harsh industrial environments meeting Moderate (G2) or Harsh (G3) airborne contaminant conditions.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConformal coating applied for corrosion protection in harsh industrial environments (ANSI\/ISA-S71.04-1985 G2\/G3 compliant).\u003c\/li\u003e\n\u003cli\u003eDirect chassis left-side mounting layout that powers the backplane without consuming an I\/O or controller slot position.\u003c\/li\u003e\n\u003cli\u003eAccepts 24 VDC input source power for non-redundant system applications.\u003c\/li\u003e\n\u003cli\u003eSupplies 1.2 V, 3.3 V, 5.1 V, and 24.0 V DC power directly to the chassis backplane.\u003c\/li\u003e\n\u003cli\u003eIntegrated soldered non-replaceable fuse for short-circuit fire hazard protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExperion C200 \/ C200E Control Processor Chassis Systems\u003c\/li\u003e\n\u003cli\u003eExperion Chassis Series-A (CIOM-A) Remote I\/O Racks\u003c\/li\u003e\n\u003cli\u003eIndustrial Process Control and Automation Systems\u003c\/li\u003e\n\u003cli\u003eHarsh chemical or industrial plant environments requiring G2\/G3 airborne contaminant resistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTK-FPDXX2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConformal Coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard (non-redundant) Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2-32 VDC (Input may drop to 16 V for a maximum of 2 minutes each hour for motor starting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Inrush Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Power Output Maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 W @ 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Output Current Maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1.5 A @ 1.2 V\u003c\/p\u003e\n\u003cp\u003e4 A @ 3.3 V\u003c\/p\u003e\n\u003cp\u003e10 A @ 5.1 V\u003c\/p\u003e\n\u003cp\u003e2.8 A @ 24.0 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Power Combination Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal combined output power across 1.2 V, 3.3 V, 5 V, and 24 V backplane outputs cannot exceed 70 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-replaceable fuse is soldered in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e#14 AWG (1.4 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.2 x 14.5 x 14.0 cm (4.41 x 5.71 x 5.51 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximate 1.1 kg (2.5 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLeft side of chassis (does not consume a slot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC (32 to 140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 degC (-40 to 185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95% noncondensing (de-rated to 55% above 40 degC to maintain constant moisture content)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Change Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 degC\/min. (\u0026lt;= 5 degC\/min. storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-300 to +3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration (3 axes)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 60 Hz, 0.5 g max. acceleration, 0.1 inches displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Shock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 g max. acceleration, 30 ms max. duration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Position:\u003c\/strong\u003e Install the power supply module directly onto the left side of the Experion Series-A chassis. The power supply module does not occupy a standard module slot position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Requirements:\u003c\/strong\u003e Use #14 AWG (1.4 mm) copper conductors for the input power connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Requirements:\u003c\/strong\u003e Maintain appropriate physical clearances around the chassis (minimum 15.2 cm \/ 6.0 in vertical distance to cabinet, 10.2 cm \/ 4.0 in horizontal distance to cabinet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e Ensure ambient operating temperatures around the unit do not exceed 60 degC to maintain full 70 W total power output capability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e UL 508 Industrial Control Equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Locations:\u003c\/strong\u003e Class I, Div 2, Groups A, B, C \u0026amp; D Hazardous and Ordinary locations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e 89\/336\/EEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmissions:\u003c\/strong\u003e EN 50081-2, Industrial\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImmunity:\u003c\/strong\u003e EN 50082-2, Industrial\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC-Tick:\u003c\/strong\u003e Meets requirements of the Australian Radiocommunications Act of 1992, Section 182, relating to electromagnetic compatibility\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52668038480235,"sku":"TK-FPDXX2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-tk-fpdxx2-power-supply-module-aptopzs0xde_8695dedf-a019-4a9f-9520-1d7e0f5768fe.jpg?v=1765505411","url":"https:\/\/www.plcprotech.com\/products\/honeywell-tk-fpdxx2-chassis-series-a-standard-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}