{"product_id":"honeywell-tk-iol101-experion-pks-io-link-module","title":"Honeywell TK-IOL101 Experion PKS IO-Link Module","description":"\u003cp style=\"color: #2d3748; margin-bottom: 16px;\"\u003eThe Honeywell TK-IOL101 functions as a high-density, field-mountable industrial interface component designed exclusively for integration within the \u003cstrong\u003eExperion PKS Distributed Control System (DCS)\u003c\/strong\u003e architecture. This robust module establishes point-to-point bidirectional communication between intelligent \u003cstrong\u003eIO-Link enabled digital sensors\u003c\/strong\u003e, actuators, and the controller layer. By translating complex field device diagnostics and process data into deterministic control signals, the unit eliminates field wiring complexity while expanding the diagnostic capabilities of modern automation infrastructures.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 4px; margin-top: 24px; margin-bottom: 12px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 16px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eProvides native point-to-point digital communication via standard IO-Link version 1.1 protocol.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eTransmits cyclic process data, acyclic parameter data, and extensive device events to the host system.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eFacilitates remote configuration and real-time device parameterization to reduce physical field maintenance.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eEquipped with comprehensive onboard LED diagnostic indicators tracking module health and port communication status.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eRuggedized industrial build quality designed to withstand harsh electromagnetic interference and mechanical vibrations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 4px; margin-top: 24px; margin-bottom: 12px;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 16px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003ePetrochemical processing and oil refining control topologies requiring distributed smart sensing networks.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eContinuous manufacturing plants leveraging Experion PKS or Experion LS DCS environments.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003ePower generation facilities utilizing smart field devices for balance-of-plant automation.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eWater and wastewater treatment infrastructure requiring remote instrument parameter tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 4px; margin-top: 24px; margin-bottom: 12px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 16px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; min-width: 500px;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold; width: 40%;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold; width: 60%;\"\u003eVerified Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTK-IOL101\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eI\/O Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSystem Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eHoneywell Experion PKS \/ LS Series\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInterface Protocol\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIO-Link V1.1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNet Module Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.45 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e28.5 cm x 18.2 cm x 12.4 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 4px; margin-top: 24px; margin-bottom: 12px;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 12px; color: #9b2c2c; margin-bottom: 16px;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Isolate all primary and auxiliary power sources feeding the local I\/O rack or mounting chassis prior to hardware extraction or insertion. Failure to de-energize equipment can induce backplane voltage transients, leading to permanent module destruction, corrupted firmware states, or unintended field instrument actuation. Follow plant lock-out\/tag-out protocols strictly.\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/span\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eInspect the chassis mounting slot for particulate contamination, ensuring the rear backplane connectors are free of debris or bent pins.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/span\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eAlign the module card edge accurately within the plastic chassis guide rails, ensuring a perpendicular entry trajectory to the target slot.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/span\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eSlide the unit firmly inward until the faceplate mounting mechanisms seat completely and latch with the underlying assembly base.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 12px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/span\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eSecure all manual retaining fasteners to establish a robust ground connection between the chassis framework and the integrated shield ground.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 16px; display: flex; align-items: flex-start;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: inline-flex; align-items: center; justify-content: center; margin-right: 12px; flex-shrink: 0; font-weight: bold;\"\u003e5\u003c\/span\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eRe-apply power, monitor the initial power-on self-test sequences via the LED matrix, and execute online module assignment within the Experion software toolset.\u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705310638443,"sku":"TK-IOL101","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tk-iol101-53gbyz4nutt_867b1c94-db39-435b-bee9-706034cb9384.jpg?v=1766639496","url":"https:\/\/www.plcprotech.com\/products\/honeywell-tk-iol101-experion-pks-io-link-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}