{"product_id":"honeywell-tk-orc161-97180373-chassis-series-a-isolated-discrete-relay-module","title":"Honeywell TK-ORC161 97180373 Chassis Series-A Isolated Discrete Relay Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell TK-ORC161\u003c\/strong\u003e is a conformal-coated, 16-point isolated discrete relay output module designed for the Experion Chassis Series-A (CIOM-A) I\/O platform. The device operates within Experion LS systems in conjunction with C200E\/C200 control processors over the I\/O ControlNet network. Featuring 16 individually isolated Normally Open (N.O.) relay contacts, the module provides high-density discrete output switching capabilities for a wide variety of field devices, loads, and industrial control applications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e Includes factory-applied conformal coating (TK series) for enhanced corrosion protection in harsh industrial environments (ANSI\/ISA-S71.04-1985 Moderate G2 or Harsh G3 classification).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Channel Count:\u003c\/strong\u003e Equipped with 16 N.O. relay contact output channels in a single-wide chassis slot form factor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividual Galvanic Isolation:\u003c\/strong\u003e Provides point-to-point channel isolation (16 N.O. contacts individually isolated) to ensure electrical independence and signal integrity across field circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Switching Capacities:\u003c\/strong\u003e Handles switching voltages from 10 to 265 VAC (47-63 Hz) and 5 to 150 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Channel States:\u003c\/strong\u003e Features user-configurable Fault States and Program Mode states per point (Hold Last State, ON, or OFF; default is OFF).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swappable:\u003c\/strong\u003e Supports Removal and Insertion Under Power (RIUP) in non-hazardous\/ordinary locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMotor starter control circuits\u003c\/li\u003e\n\u003cli\u003eSolenoid valve actuation\u003c\/li\u003e\n\u003cli\u003eAnnunciator panels and alarm indication outputs\u003c\/li\u003e\n\u003cli\u003eHigh-voltage interlock and isolation switching\u003c\/li\u003e\n\u003cli\u003eInterfacing field actuators with C200E\/C200 Control Processors in process control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTK-ORC161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 N.O. (Contacts individually isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 265 VAC (47-63 Hz) \/ 5 to 150 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Range (Load Dependent)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5-30 VDC @ 2.0 A resistive\u003c\/p\u003e\n\u003cp\u003e48 VDC @ 0.5 A resistive\u003c\/p\u003e\n\u003cp\u003e125 VDC @ 0.25 A resistive\u003c\/p\u003e\n\u003cp\u003e125 VAC @ 2.0 A resistive\u003c\/p\u003e\n\u003cp\u003e240 VAC @ 2.0 A resistive\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current Rating (Resistive)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2.0 A steady state @ 5-30 VDC\u003c\/p\u003e\n\u003cp\u003e0.5 A steady state @ 48 VDC\u003c\/p\u003e\n\u003cp\u003e0.25 A steady state @ 125 VDC\u003c\/p\u003e\n\u003cp\u003e2.0 A steady state, 15 A make @ 125 VAC\u003c\/p\u003e\n\u003cp\u003e2.0 A steady state, 15 A make @ 240 VAC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating (Steady State)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e250 W max for 125 VAC resistive\u003c\/p\u003e\n\u003cp\u003e480 W max for 240 VAC resistive\u003c\/p\u003e\n\u003cp\u003e60 W max for 30 VDC resistive\u003c\/p\u003e\n\u003cp\u003e24 W max for 48 VDC resistive\u003c\/p\u003e\n\u003cp\u003e31 W max for 125 VDC resistive\u003c\/p\u003e\n\u003cp\u003e250 VA max for 125 VAC inductive\u003c\/p\u003e\n\u003cp\u003e480 VA max for 240 VAC inductive\u003c\/p\u003e\n\u003cp\u003e60 VA max for 30 VDC inductive\u003c\/p\u003e\n\u003cp\u003e24 VA max for 48 VDC inductive\u003c\/p\u003e\n\u003cp\u003e31 VA max for 125 VDC inductive\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Load Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInitial Contact Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 meg-Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 operation per 3 seconds (0.3 Hz at rated load) maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBounce Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 ms (mean)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Contact Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300K cycles resistive \/ 100K cycles inductive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Off-State Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Delay Time (OFF to ON \/ ON to OFF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfigurable Fault \/ Program Mode States\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHold Last State, ON or OFF (OFF is default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Power Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 W @ 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.35 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V maximum continuous; 100% tested at 2546 VDC for 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTC-TBCH, 36-Position Terminal Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC300, R150 Pilot Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Slot Placement:\u003c\/strong\u003e The module occupies a single-wide slot within any position of an Experion Series-A chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring:\u003c\/strong\u003e Connect field wiring directly using the TC-TBCH 36-pin terminal block or via pre-wired cable assembly connected to a Remote Terminal Panel (RTP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFusing Protection:\u003c\/strong\u003e Outputs are not internally fused; use a fused RTP (e.g., Allen-Bradley 1492 interface system) to protect module output circuits against overcurrent conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemoval and Insertion Under Power (RIUP):\u003c\/strong\u003e Permitted in ordinary, non-hazardous locations. RIUP is strictly \u003cstrong\u003eNOT PERMITTED\u003c\/strong\u003e when installed in Class I, Division 2 hazardous locations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Requirements:\u003c\/strong\u003e Maintain compliance with ambient environment criteria (0 to 60 degC operative temperature limits) inside an industrial enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL:\u003c\/strong\u003e UL 508 Industrial Control Equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Locations:\u003c\/strong\u003e Class I, Div 2, Groups A, B, C \u0026amp; D Hazardous and Ordinary locations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e 89\/336\/EEC, EN 50081-2 Emissions, EN 50082-2 Immunity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC-Tick:\u003c\/strong\u003e Meets requirements of the Australian Radiocommunications Act of 1992\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52667751235947,"sku":"TK-ORC161","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/honeywell-tk-orc161-97180373-relay-output-module-3ybso3avw3w_8ae20af8-3b52-4842-8b9e-1bb495f2f192.jpg?v=1765501558","url":"https:\/\/www.plcprotech.com\/products\/honeywell-tk-orc161-97180373-chassis-series-a-isolated-discrete-relay-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}