{"product_id":"honeywell-tk-prs022-experion-pks-c200e-control-processor","title":"Honeywell TK-PRS022 EXPERION PKS C200E Control Processor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell TK-PRS022\u003c\/strong\u003e is a high-performance \u003cstrong\u003eC200E Control Processor Module (CPM)\u003c\/strong\u003e engineered for the \u003cstrong\u003eExperion PKS\u003c\/strong\u003e (Process Knowledge System) architecture. As an enhanced evolution of the legacy C200 controller platform, this chassis-based module serves as the primary processing core for demanding industrial distributed control system (DCS) nodes. The \u003cstrong\u003eTK-PRS022\u003c\/strong\u003e significantly expands processing capabilities by increasing user memory from 4 MB up to 16 MB, allowing for more complex control strategies, higher block counts, and advanced data array handling.\u003c\/p\u003e\n\u003cp\u003eThe module features an integrated multi-slot chassis footprint (occupying default slots 1 and 2) and coordinates data transport across the backplane to peripheral components including I\/O Link Interfaces, Redundancy Modules, Fault Tolerant Ethernet (FTE) interfaces, and Fieldbus communication cards. Designed with the \"K\" designation, this variant features an engineering-grade conformal coating on its Printed Wiring Assemblies (PWAs) to withstand severe industrial environments subject to airborne contaminants, moisture, and corrosive elements.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnhanced memory capacity containing 16 MB of onboard user memory.\u003c\/li\u003e\n\u003cli\u003eDouble-slot width chassis-based layout for robust thermal dissipation and backplane connectivity.\u003c\/li\u003e\n\u003cli\u003eFull programmatic and architectural compatibility with standard C200 control execution environments.\u003c\/li\u003e\n\u003cli\u003eConformal coated PWAs (\"K\" suffix) providing enhanced protection against environmental corrosion.\u003c\/li\u003e\n\u003cli\u003eSupports both non-redundant and high-availability redundant controller configurations.\u003c\/li\u003e\n\u003cli\u003eHigh-speed interface integration with FTE, ControlNet, and local\/remote I\/O structures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExperion PKS DCS Process Control execution\u003c\/li\u003e\n\u003cli\u003eCritical infrastructure and continuous process orchestration\u003c\/li\u003e\n\u003cli\u003eRedundant supervisory and peer-to-peer control networks\u003c\/li\u003e\n\u003cli\u003eCorrosive or high-humidity industrial control environments (Refineries, Chemical Plants)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eTK-PRS022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eC200E Control Processor Module (CPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eSystem Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eExperion PKS C200E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eUser Memory Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e16 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eChassis Slot Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e2 Slots (Default slots 1 and 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003ePWA Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eConformally coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eConfiguration Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eNon-redundant or redundant pairing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eExperion Control Builder Environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eBase Hardware Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eChassis-based plug-in configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Allocation:\u003c\/strong\u003e Identify the targeted chassis slot location for mounting the module. The default assignment occupies slots 1 and 2. Note that chassis slot numbering is zero-based, where the leftmost slot is numbered \"0\".\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Mitigation:\u003c\/strong\u003e Prior to unpacking or handling the module, review standard pre-installation considerations and execute proper grounding procedures to minimize Electrostatic Discharge (ESD) hazards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Verify that all power sources to the host chassis are completely disconnected. Align the circuit board of the module with the top and bottom card guides of the chassis slots, then slide the unit backward firmly until it seats completely into the backplane connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Sync:\u003c\/strong\u003e For redundant pairs, coordinate implementation rules according to the Experion Control Builder Components Theory and establish proper tracking links over the dedicated redundancy module interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eApproved for Experion PKS C200\/C200E System Topologies\u003c\/li\u003e\n\u003cli\u003eConformal Coating Specification compliance for harsh environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between the standard C200 and the C200E module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe C200E control processor features significantly increased user memory, expanding from the legacy 4 MB up to 16 MB.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"K\" character signify in the model number TK-PRS022?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe letter K indicates that the Printed Wiring Assemblies are conformally coated to offer enhanced resistance to environmental contamination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this specific model number be deployed in a redundant controller topology?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it is designed to operate seamlessly in both non-redundant and redundant control hardware architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many slots does this control processor occupy within the chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is a double-wide assembly that occupies two standard chassis slots.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the default chassis slot positions for this processor module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe factory default installation positioning allocates slots 1 and 2 for the primary or secondary control processor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould the chassis be live or powered down when executing installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlways ensure that no primary or auxiliary power is applied to the chassis during insertion or removal procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre the installation procedures for the TC-PRS021 and TK-PRS022 identical?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the mechanical installation steps, card alignment, and physical chassis tracking procedures are identical for both models.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat system utility is used to program or configure the processor logic?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eControl strategies and hardware options are managed using the Experion Control Builder environment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the module aligned during initial physical cabinet mounting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe top and bottom edges of the module circuit board must align exactly with the built-in plastic chassis track guides before sliding it backward.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this part number include the local I\/O link interface or redundancy module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, this part number represents the core C200E Control Processor Module alone; separate plug-in modules handle network and I\/O interfaces.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52679385186667,"sku":"TK-PRS022","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/TK-PRS022-g2rehjg1zub_73ef981e-57fd-42a2-aefe-3dcbb59f74ed.jpg?v=1765958309","url":"https:\/\/www.plcprotech.com\/products\/honeywell-tk-prs022-experion-pks-c200e-control-processor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}