{"product_id":"honeywell-tk-rpcxx1-series-c-redundant-power-carrier-module","title":"Honeywell TK-RPCXX1 Series C Redundant Power Carrier Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProviding regulated electrical distribution to Experion Series C chassis, the \u003cstrong\u003eHoneywell TK-RPCXX1\u003c\/strong\u003e serves as a reliable redundant power supply carrier within process automation environments. Engineered with a robust, \u003cstrong\u003econformal coated\u003c\/strong\u003e assembly, this module is specifically hardened against moisture, dust, and corrosive airborne contaminants typical of heavy industrial facilities. It accepts dual wide-range AC inputs to ensure continuous control system operation even in the event of a primary power feed failure.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConformal Coated Circuitry:\u003c\/strong\u003e Designed for installation in harsh, Class G3 environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Redundant Power Architecture:\u003c\/strong\u003e Enhances system availability by facilitating hot-swappable secondary power supply configurations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Annunciation Relay:\u003c\/strong\u003e Built-in solid-state relay detects power failures and trips external diagnostic alarms.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWide AC Input Acceptance:\u003c\/strong\u003e Accommodates global voltage standards from 85 to 265 VAC without manual switching.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eExperion PKS Series C controller backplane power distribution.\u003c\/li\u003e\n  \u003cli\u003ePetrochemical and oil refinery distributed control systems (DCS).\u003c\/li\u003e\n  \u003cli\u003eCritical process industries requiring uninterruptible fieldbus and I\/O power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eHoneywell\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eTK-RPCXX1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eEnvironmental Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eConformal Coated\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e85 - 265 VAC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Power Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e110 VA \/ 110 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eFrequency Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e47 - 63 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMaximum Inrush Current\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e20 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTotal Output Power (Max)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e75 W at 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eBackplane Output Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e15 A at 5.0 V \/ 1.5 A at 15.0 V \/ 1.5 A at -15.0 V \/ 2.8 A at 24.0 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput Wiring Gauge\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e#14 AWG (1.4 mm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAnnunciation Relay Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSolid state, 120 VAC\/DC at 100 mA maximum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRequired Cable Model\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eTC-RPSC03 (3 ft, redundant power supply connection)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModule Dimensions (L x D x H)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e14.4 x 13.7 x 17.5 cm (5.67 x 5.39 x 6.89 in)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCarrier Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.1 kg (2.5 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 2.0 kg;\"\u003e2.0 kg (4.4 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe TK-RPCXX1 is the conformal-coated variant of the standard TC-RPCXX1 power carrier. In highly corrosive environments, the \"TK\" prefix series must be selected over the \"TC\" series to ensure long-term trace resilience against ambient hydrogen sulfide and chlorine. This carrier interfaces seamlessly with Honeywell Series C systems and connects via the TC-RPSC03 redundancy cable assembly.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eMaximum output power drops linearly above 60 degC ambient operating temperatures. Ensure that the module is mounted strictly in an upright orientation. Standard rack or panel configurations require at least 5 cm of clear space above and below the carrier chassis to allow natural thermal convection and avoid local hot spots inside the enclosure.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo minimize voltage sag and line-noise coupling, use exactly #14 AWG (1.4 mm) copper wire for the main AC feed. The integrated solid-state annunciation relay is highly sensitive to overcurrent; do not exceed the 100 mA load limit during commissioning tests, and always employ an external interposing relay if switching higher-current industrial indicator circuits.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate and lock out all AC mains feeding the panel before attempting installation. Capacitors inside the connected power supply units store dangerous residual charge. Wait at least 5 minutes after physical de-energization before disconnecting or servicing cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSecurely bolt the carrier chassis vertically in the designated system enclosure space, allowing clearance for proper ventilation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the TC-RPSC03 redundant power supply cable to the carrier connector, hand-tightening any locking screws.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eRoute and clamp the incoming AC supply conductors (#14 AWG) into the screw terminal block, ensuring correct polarity and solid ground termination.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the solid-state alarm relay outputs to your distributed control system (DCS) monitoring inputs to complete commissioning setup.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52705316733291,"sku":"TK-RPCXX1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/tk-rpcxx1-fzf0ifuqorv_7348efff-ffdc-4642-b2e7-070b44cb071a.jpg?v=1766639659","url":"https:\/\/www.plcprotech.com\/products\/honeywell-tk-rpcxx1-series-c-redundant-power-carrier-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}