{"product_id":"ics-triplex-t8110-trusted-tmr-processor-module","title":"ICS Triplex T8110 Trusted TMR Processor Module","description":"\u003cp\u003eThe \u003cstrong\u003eICS Triplex T8110\u003c\/strong\u003e is a main processing component designed for high-integrity automation and safety applications within a Trusted system. The \u003cstrong\u003eICS Triplex T8110\u003c\/strong\u003e provides overall system control and monitoring facilities while processing input and output data received from various analogue and digital I\/O modules across a triplicated Inter-Module Communications Bus. Utilizing a Triple Modular Redundant architecture operating in a lock-step configuration, it is suitable for critical industrial applications including fire and gas control, emergency shutdown, monitoring and control, and turbine control.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTriple Modular Redundant (TMR), fault-tolerant (3-2-0) operation.\u003c\/li\u003e\n\u003cli\u003eHardware Implemented Fault Tolerant (HIFT) architecture.\u003c\/li\u003e\n\u003cli\u003eDedicated hardware and software test regimes for fast fault recognition and response times.\u003c\/li\u003e\n\u003cli\u003eAutomatic fault handling without nuisance alarming.\u003c\/li\u003e\n\u003cli\u003eTime-stamped fault historian.\u003c\/li\u003e\n\u003cli\u003eHot replacement capability without the need to re-load programs.\u003c\/li\u003e\n\u003cli\u003eFull suite of IEC 61131-3 programming languages.\u003c\/li\u003e\n\u003cli\u003eFront panel status indicators displaying module health and operational state.\u003c\/li\u003e\n\u003cli\u003eFront panel RS232 serial diagnostics port for system monitoring, configuration, and programming.\u003c\/li\u003e\n\u003cli\u003eActive and Standby processor fault and failure relay contacts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFire and Gas Control Systems\u003c\/li\u003e\n\u003cli\u003eEmergency Shutdown (ESD) Systems\u003c\/li\u003e\n\u003cli\u003eCritical Process Monitoring and Control\u003c\/li\u003e\n\u003cli\u003eTurbine Control Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eICS Triplex \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e20 Vdc to 32 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load\u003c\/td\u003e\n\u003ctd\u003e80 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e80 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Chassis\u003c\/td\u003e\n\u003ctd\u003eT8100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Clock\u003c\/td\u003e\n\u003ctd\u003e100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Type and Size (DRAM)\u003c\/td\u003e\n\u003ctd\u003e16 MB EDO 60 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Type and Size (EPROM)\u003c\/td\u003e\n\u003ctd\u003e512 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Type and Size (FLASH)\u003c\/td\u003e\n\u003ctd\u003e2 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Type and Size (NVRAM)\u003c\/td\u003e\n\u003ctd\u003e128 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRetained Variable Storage\u003c\/td\u003e\n\u003ctd\u003e4 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Buffer Size\u003c\/td\u003e\n\u003ctd\u003e1000 events (transferred to CI buffer of 4000 events)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Interface\u003c\/td\u003e\n\u003ctd\u003eTriple redundant Inter-Module Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 degC to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e266 mm x 93 mm x 303 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.94 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-A2\u003c\/td\u003e\n\u003ctd\u003eFault relay (NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-A4\u003c\/td\u003e\n\u003ctd\u003eFault relay (common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-A6\u003c\/td\u003e\n\u003ctd\u003eFault relay (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-A10\u003c\/td\u003e\n\u003ctd\u003e5V D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-A12\u003c\/td\u003e\n\u003ctd\u003eDATA_OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-A14\u003c\/td\u003e\n\u003ctd\u003eENABLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-A16\u003c\/td\u003e\n\u003ctd\u003eDATA_IN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-A18\u003c\/td\u003e\n\u003ctd\u003eCLK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-A20\u003c\/td\u003e\n\u003ctd\u003e0V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-A22\u003c\/td\u003e\n\u003ctd\u003eChassis GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-A24\u003c\/td\u003e\n\u003ctd\u003eChassis GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-A26\u003c\/td\u003e\n\u003ctd\u003eChassis GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-A28\u003c\/td\u003e\n\u003ctd\u003e24 V PSU 1 LV Warning Shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-A30\u003c\/td\u003e\n\u003ctd\u003e24 V PSU 2 LV Warning Shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-A32\u003c\/td\u003e\n\u003ctd\u003e24 V Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-C2\u003c\/td\u003e\n\u003ctd\u003eDIAG_RTN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-C4\u003c\/td\u003e\n\u003ctd\u003eDIAG_IN_1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-C6\u003c\/td\u003e\n\u003ctd\u003e0 V Port 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-C8\u003c\/td\u003e\n\u003ctd\u003eSerial Port 1 B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-C10\u003c\/td\u003e\n\u003ctd\u003eSerial Port 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-C12\u003c\/td\u003e\n\u003ctd\u003e0V Port 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-C14\u003c\/td\u003e\n\u003ctd\u003eSerial Port 2 B TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-C16\u003c\/td\u003e\n\u003ctd\u003eSerial Port 2 A TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-C18\u003c\/td\u003e\n\u003ctd\u003eSerial Port 2 B RX\/TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-C20\u003c\/td\u003e\n\u003ctd\u003eSerial Port 2 A RX\/TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-C22\u003c\/td\u003e\n\u003ctd\u003e0 V Port 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-C24\u003c\/td\u003e\n\u003ctd\u003eSerial Port 3 B TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-C26\u003c\/td\u003e\n\u003ctd\u003eSerial Port 3 A TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-C28\u003c\/td\u003e\n\u003ctd\u003eSerial Port 3 B RX\/TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-C30\u003c\/td\u003e\n\u003ctd\u003eSerial Port 3 A RX\/TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-C32\u003c\/td\u003e\n\u003ctd\u003e24 V Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-E2\u003c\/td\u003e\n\u003ctd\u003eFailed relay (NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-E4\u003c\/td\u003e\n\u003ctd\u003eFailed relay (common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-E6\u003c\/td\u003e\n\u003ctd\u003eFailed relay (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-E10\u003c\/td\u003e\n\u003ctd\u003eIRIG-B122+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-E12\u003c\/td\u003e\n\u003ctd\u003eIRIG-B122-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-E18\u003c\/td\u003e\n\u003ctd\u003eIRIG-B002-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-E20\u003c\/td\u003e\n\u003ctd\u003eIRIG-B002+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-E22\u003c\/td\u003e\n\u003ctd\u003eChassis GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-E24\u003c\/td\u003e\n\u003ctd\u003eChassis GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-E26\u003c\/td\u003e\n\u003ctd\u003eChassis GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-E28\u003c\/td\u003e\n\u003ctd\u003e24V PSU 1 Fail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-E30\u003c\/td\u003e\n\u003ctd\u003e24V PSU 2 Fail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePL1-E32\u003c\/td\u003e\n\u003ctd\u003e24V Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspection:\u003c\/strong\u003e Visually inspect the module housing and rear I\/O connector pins for damage or bending prior to installation. Do not attempt to straighten bent pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Precautions:\u003c\/strong\u003e Static handling precautions must be observed. Avoid touching exposed connector pins and do not dismantle the module housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Open the ejector tabs fully using the release key, insert the module carefully into the designated slot, and press on the top and bottom fascia until seated. Close ejector tabs to lock in place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive\/Standby Transfer Safety:\u003c\/strong\u003e Under no circumstances remove a module indicating Active mode. Removal of an active module may result in system shutdown or default states being adopted.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTÜV Certified IEC 61508 SIL 3\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":53649639932267,"sku":"T8110","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/T8110-3.jpg?v=1785649998","url":"https:\/\/www.plcprotech.com\/products\/ics-triplex-t8110-trusted-tmr-processor-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}