{"product_id":"ics-triplex-t8110b-trusted-tmr-processor-module","title":"ICS Triplex T8110B Trusted TMR Processor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eICS Triplex T8110B\u003c\/strong\u003e is a Triple Modular Redundant (\u003cstrong\u003eTMR\u003c\/strong\u003e), fault-tolerant main processor module operating in a lock-step configuration. The module serves as the primary processing component in a \u003cstrong\u003eTrusted\u003c\/strong\u003e System, providing overall system control, monitoring facilities, and processing input and output data across a \u003cstrong\u003eTrusted TMR\u003c\/strong\u003e Inter-Module Communications Bus. Equipped with a Hardware Implemented Fault Tolerant (\u003cstrong\u003eHIFT\u003c\/strong\u003e) architecture and three Motorola PowerPC series processors, it performs 2-out-of-3 (\u003cstrong\u003e2oo3\u003c\/strong\u003e) voted operations to eliminate divergent execution. The \u003cstrong\u003eICS Triplex T8110B\u003c\/strong\u003e features hardware-based time synchronization support via \u003cstrong\u003eIRIG-B002\u003c\/strong\u003e and \u003cstrong\u003eIRIG-B122\u003c\/strong\u003e signals, configurable serial communication links, and integrated fault historian capabilities for high-integrity applications such as emergency shutdown, fire and gas control, and turbine control.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTriple Modular Redundant (\u003cstrong\u003eTMR\u003c\/strong\u003e), fault-tolerant (3-2-0) operation using Hardware Implemented Fault Tolerant (\u003cstrong\u003eHIFT\u003c\/strong\u003e) architecture\u003c\/li\u003e\n\u003cli\u003eThree Motorola PowerPC series processors executing in lock-step synchronization with voted \u003cstrong\u003e2oo3\u003c\/strong\u003e memory access\u003c\/li\u003e\n\u003cli\u003eTime-stamped Sequence of Events (\u003cstrong\u003eSOE\u003c\/strong\u003e) log with \u003cstrong\u003eIRIG-B002\u003c\/strong\u003e and \u003cstrong\u003eIRIG-B122\u003c\/strong\u003e time synchronization support\u003c\/li\u003e\n\u003cli\u003eBuilt-in hardware diagnostic port, active\/standby processor support, and fault\/fail relay contacts\u003c\/li\u003e\n\u003cli\u003eFront panel status LEDs indicating individual slice health, active\/standby status, and system health\u003c\/li\u003e\n\u003cli\u003eHot-replacement capability without requiring program re-loads\u003c\/li\u003e\n\u003cli\u003eNon-volatile memory data retention for up to 10 years\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency Shutdown (ESD) Systems\u003c\/li\u003e\n\u003cli\u003eFire and Gas (F\u0026amp;G) Protection Systems\u003c\/li\u003e\n\u003cli\u003eCritical Burner Management Systems (BMS)\u003c\/li\u003e\n\u003cli\u003eTurbine Control and Protection Systems\u003c\/li\u003e\n\u003cli\u003eHigh-Integrity Pressure Protection Systems (HIPPS)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eICS Triplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT8110B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrusted TMR Processor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 Vdc to 32 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT8100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDRAM Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 MB EDO 60 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEPROM Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e512 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFLASH Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNVRAM Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128 kB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRetained Variable Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSOE Buffer Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 events (transferred to CI buffer of 4000 events)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTriple redundant Inter-Module Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 degC to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 degC to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e266 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e303 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.94 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFault relay (NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFault relay (common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFault relay (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5V D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDATA_OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 14\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eENABLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 16\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDATA_IN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 18\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCLK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 22 \/ 24 \/ 26\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChassis GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 28\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V PSU 1 LV Warning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V PSU 2 LV Warning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 32\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIAG_RTN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIAG_IN_1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 V Port 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 1 B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0V Port 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 14\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 2 B TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 16\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 2 A TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 18\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 2 B RX\/TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 2 A RX\/TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 22\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 V Port 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 24\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 3 B TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 26\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 3 A TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 28\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 3 B RX\/TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 3 A RX\/TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 32\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFailed relay (NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFailed relay (common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFailed relay (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIRIG-B122+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIRIG-B122-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 18\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIRIG-B002-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIRIG-B002+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 22 \/ 24 \/ 26\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChassis GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 28\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V PSU 1 Fail Shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V PSU 2 Fail Shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 32\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Ensure field cable assemblies are correctly located. Release ejector tabs using the release key to ensure they are fully open. Insert the module firmly into its slot until front panel LEDs illuminate, then push fully home and lock the ejector tabs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Precautions:\u003c\/strong\u003e Static handling precautions must be strictly observed. Do not touch exposed connector pins, and under no circumstances remove or dismantle the protective module housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual Inspection:\u003c\/strong\u003e Prior to installation, inspect the rear I\/O connector pins for physical damage or bends. Never force a module into a slot if high resistance is encountered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e Ensure proper connection of the chassis connection signal to establish effective electromagnetic interference shield grounding on the backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61508:\u003c\/strong\u003e TÜV Certified SIL 3\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":53240108056939,"sku":"T8110B","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/T8110B_1.jpg?v=1785217043","url":"https:\/\/www.plcprotech.com\/products\/ics-triplex-t8110b-trusted-tmr-processor-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}