{"product_id":"ics-triplex-t8111-trusted-tmr-processor-module","title":"ICS Triplex T8111 Trusted TMR Processor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eICS Triplex T8111\u003c\/strong\u003e is a fault-tolerant main processing component designed for the \u003cstrong\u003eTrusted\u003c\/strong\u003e system architecture. Operating in a Triple Modular Redundant (TMR) lock-step configuration across three independent Processor fault containment regions (FCRs), the \u003cstrong\u003eT8111\u003c\/strong\u003e executes user-defined application programs, performs system monitoring, and manages I\/O data exchanges across the triplicated Inter-Module Bus. The module integrates two configurable RS422\/485 serial ports, one dedicated RS485 2-wire serial port, an RS232 front panel diagnostic interface, and built-in IRIG-B time synchronization capabilities. The \u003cstrong\u003eICS Triplex T8111\u003c\/strong\u003e is designed for critical safety instrumented functions and process control applications requiring high availability and fault isolation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTriple Modular Redundant (TMR) architecture with Hardware Implemented Fault Tolerant (HIFT) clock and voting mechanics.\u003c\/li\u003e\n\u003cli\u003eThree NXP PowerQUICC II series processors executing application logic in lock-step synchronization.\u003c\/li\u003e\n\u003cli\u003eSupport for hot replacement in Companion Slot active\/standby configurations without program re-loading.\u003c\/li\u003e\n\u003cli\u003eIntegrated IRIG-B002 (RS422\/485) and IRIG-B122 (1 kHz modulated) time synchronization inputs.\u003c\/li\u003e\n\u003cli\u003eFront panel RS232 serial diagnostic port and status\/diagnostic LED indicators.\u003c\/li\u003e\n\u003cli\u003eActive and Standby processor fault and fail relay contact outputs.\u003c\/li\u003e\n\u003cli\u003eIEC 61131-3 programming language support via the system toolset.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSafety Instrumented Systems (SIS)\u003c\/li\u003e\n\u003cli\u003eEmergency Shutdown Systems (ESD)\u003c\/li\u003e\n\u003cli\u003eFire and Gas Detection Systems (F\u0026amp;G)\u003c\/li\u003e\n\u003cli\u003eCritical Process Control Systems\u003c\/li\u003e\n\u003cli\u003eBurner Management Systems (BMS)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eICS Triplex \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT8111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane (IMB) Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 Vdc to 32 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT8100 Processor Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Communications Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Rear Serial Ports (RS-422\/485), 1 Diagnostics Serial Port (RS-232)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime Sync Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 IRIG-B002, 1 IRIG-B122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Fault Relay (0.5 A @ 24 Vdc), 1 Fail Relay (0.5 A @ 24 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaud Rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9600 baud to 115200 baud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunications Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus RTU (via Rear Serial Ports)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Application Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e960 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRetained Variable Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 KB total (1 byte per Boolean, 4 bytes per Analogue, 5 bytes per Timer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSOE Buffer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 degC to 60 degC (32 degF to 140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 degC to 70 degC (-13 degF to 158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10%-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e266 mm x 93 mm x 303 mm (10.5 in x 3.6 in x 12.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.89 kg (4.17 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFault relay (NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFault relay (COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFault relay (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 22, 24, 26\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChassis GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 28\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 3 B RX\/TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 3 A RX\/TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row A Pin 32\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 V Port 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 1 B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 V Port 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 14\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 2 B TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 16\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 2 A TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 18\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 2 B RX\/TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 2 A RX\/TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 22\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 V Port 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 24\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 3 B TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 26\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 3 A TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 28\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V PSU 1 LV Warning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V PSU 2 LV Warning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row C Pin 32\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFail relay (NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFail relay (COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFail relay (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIRIG-B122+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIRIG-B122-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 18\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIRIG-B002-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIRIG-B002+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 22, 24, 26\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChassis GND\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 28\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V PSU 1 Fail Shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V PSU 2 Fail Shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePL1 Row E Pin 32\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V Return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVisual Inspection: Inspect the module housing and rear I\/O connectors for damaged or bent pins prior to installation. Do not attempt to straighten bent pins.\u003c\/li\u003e\n\u003cli\u003eElectrostatic Discharge Safety: Static handling precautions must be observed. Do not touch exposed connector pins or attempt to open the module housing.\u003c\/li\u003e\n\u003cli\u003eInsertion Procedure: Ensure the rear adapter unit is installed. Release top and bottom ejector tabs fully using the release key, slide the module smoothly into its designated chassis slot, and press the fascia until the ejectors click locked.\u003c\/li\u003e\n\u003cli\u003eKey Switch Positions: Set the maintenance enable keyswitch to 'Run' to lock memory during standard execution, or 'Maintain' to enable application downloads from the workstation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCertified to IEC 61508 SIL 3\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":53618505908587,"sku":"T8111","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/T8311_1_afe40af2-d7e1-41cb-b5c8-a0d20d40879d.jpg?v=1785229424","url":"https:\/\/www.plcprotech.com\/products\/ics-triplex-t8111-trusted-tmr-processor-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}