{"product_id":"ics-triplex-t8111c-trusted-tmr-processor-module","title":"ICS Triplex T8111C Trusted TMR Processor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eICS Triplex T8111C\u003c\/strong\u003e is a coated Trusted TMR Processor Module for critical control and safety applications.\u003c\/p\u003e\n\u003cp\u003eIt uses a Triple Modular Redundant architecture with three independent Processor Fault Containment Regions. Each region contains an NXP PowerQUICC II series processor.\u003c\/p\u003e\n\u003cp\u003eThe three processors operate in lock-step and continuously compare their results. Hardware-based 2-out-of-3 voting isolates a single processor fault without interrupting system operation.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eT8111C\u003c\/strong\u003e executes application programs, scans Trusted I\/O modules, and manages communications across the triplicated Inter-Module Bus.\u003c\/p\u003e\n\u003cp\u003eIts Hardware Implemented Fault Tolerant architecture supports high system availability and safety integrity in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTriple Modular Redundant architecture with fault-tolerant 3-2-0 operation.\u003c\/li\u003e\n\u003cli\u003eHardware Implemented Fault Tolerant lock-step processing.\u003c\/li\u003e\n\u003cli\u003eConformal-coated circuit assemblies for improved environmental protection.\u003c\/li\u003e\n\u003cli\u003eThree independent Processor Fault Containment Regions: FCR A, FCR B, and FCR C.\u003c\/li\u003e\n\u003cli\u003eNXP PowerQUICC II series processor within each containment region.\u003c\/li\u003e\n\u003cli\u003eHardware-based 2oo3 voting for processor, memory, and bus operations.\u003c\/li\u003e\n\u003cli\u003eContinuous discrepancy detection and automatic fault isolation.\u003c\/li\u003e\n\u003cli\u003eFront-panel status LEDs for processor and system diagnostics.\u003c\/li\u003e\n\u003cli\u003eFront-panel RS-232 serial port for diagnostic access.\u003c\/li\u003e\n\u003cli\u003eIRIG-B002 and IRIG-B122 time synchronization interfaces.\u003c\/li\u003e\n\u003cli\u003eSeparate processor fault and processor failure relay contacts.\u003c\/li\u003e\n\u003cli\u003eConfigurable serial communication interfaces through the rear adapter unit.\u003c\/li\u003e\n\u003cli\u003eHot replacement support for active and standby processor configurations.\u003c\/li\u003e\n\u003cli\u003eAutomatic standby processor education without reloading the application program.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency Shutdown Systems\u003c\/li\u003e\n\u003cli\u003eFire and Gas Detection Systems\u003c\/li\u003e\n\u003cli\u003eBurner Management Systems\u003c\/li\u003e\n\u003cli\u003eCritical Process Control Systems\u003c\/li\u003e\n\u003cli\u003eTurbomachinery Control Systems\u003c\/li\u003e\n\u003cli\u003eHigh-availability Safety Instrumented Functions rated up to SIL 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eICS Triplex \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT8111C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrusted TMR Processor Module, conformal coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMexico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 to 32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot applicable; no user-serviceable fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree NXP PowerQUICC II series processors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExecution Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTriple Modular Redundant, lock-step operation with 2oo3 voting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront-Panel Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232 diagnostic port, maintenance enable keyswitch, and fault reset button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree RS-422\/485 serial ports, one IRIG-B002 port, and one IRIG-B122 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne fault relay and one fail relay, each rated 0.5 A at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Baud Rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,600 to 115,200 baud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus RTU through the rear serial interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRetained Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 KB total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRetained Data Allocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 byte per Boolean, 4 bytes per analogue value, and 5 bytes per timer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Application Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e960 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSOE Buffer Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e266 × 93 × 303 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions in Inches\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5 × 3.6 × 12.0 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.89 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\n\u003ch4\u003eExternal I\/O Connector\u003c\/h4\u003e\n\u003cp\u003ePL1 is a 48-way DIN 41612 E-type connector located at the rear of the processor module.\u003c\/p\u003e\n\u003cp\u003eIt carries relay contacts, serial communications, time synchronization signals, and power supply monitoring connections.\u003c\/p\u003e\n\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eRow A\u003c\/th\u003e\n\u003cth\u003eRow C\u003c\/th\u003e\n\u003cth\u003eRow E\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFault relay, normally closed\u003c\/td\u003e\n\u003ctd\u003eNot connected\u003c\/td\u003e\n\u003ctd\u003eFail relay, normally closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFault relay, common\u003c\/td\u003e\n\u003ctd\u003eNot connected\u003c\/td\u003e\n\u003ctd\u003eFail relay, common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFault relay, normally open\u003c\/td\u003e\n\u003ctd\u003e0 V, Port 1\u003c\/td\u003e\n\u003ctd\u003eFail relay, normally open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot connected\u003c\/td\u003e\n\u003ctd\u003eSerial Port 1 B\u003c\/td\u003e\n\u003ctd\u003eNot connected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot connected\u003c\/td\u003e\n\u003ctd\u003eSerial Port 1 A\u003c\/td\u003e\n\u003ctd\u003eIRIG-B122+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e12\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot connected\u003c\/td\u003e\n\u003ctd\u003e0 V, Port 2\u003c\/td\u003e\n\u003ctd\u003eIRIG-B122−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e14\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot connected\u003c\/td\u003e\n\u003ctd\u003eSerial Port 2 B TX\u003c\/td\u003e\n\u003ctd\u003eReserved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e16\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot connected\u003c\/td\u003e\n\u003ctd\u003eSerial Port 2 A TX\u003c\/td\u003e\n\u003ctd\u003eReserved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e18\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot connected\u003c\/td\u003e\n\u003ctd\u003eSerial Port 2 B RX\/TX\u003c\/td\u003e\n\u003ctd\u003eIRIG-B002−\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e20\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot connected\u003c\/td\u003e\n\u003ctd\u003eSerial Port 2 A RX\/TX\u003c\/td\u003e\n\u003ctd\u003eIRIG-B002+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e22\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChassis ground\u003c\/td\u003e\n\u003ctd\u003e0 V, Port 3\u003c\/td\u003e\n\u003ctd\u003eChassis ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChassis ground\u003c\/td\u003e\n\u003ctd\u003eSerial Port 3 B TX\u003c\/td\u003e\n\u003ctd\u003eChassis ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e26\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChassis ground\u003c\/td\u003e\n\u003ctd\u003eSerial Port 3 A TX\u003c\/td\u003e\n\u003ctd\u003eChassis ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e28\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 3 B RX\/TX\u003c\/td\u003e\n\u003ctd\u003e24 V PSU 1 low-voltage warning\u003c\/td\u003e\n\u003ctd\u003e24 V PSU 1 failure shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e30\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Port 3 A RX\/TX\u003c\/td\u003e\n\u003ctd\u003e24 V PSU 2 low-voltage warning\u003c\/td\u003e\n\u003ctd\u003e24 V PSU 2 failure shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e32\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V return\u003c\/td\u003e\n\u003ctd\u003e24 V return\u003c\/td\u003e\n\u003ctd\u003e24 V return\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\n\u003ch4\u003eHandling Precautions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFollow standard electrostatic discharge precautions before handling the module.\u003c\/li\u003e\n\u003cli\u003eDo not touch exposed backplane connector pins.\u003c\/li\u003e\n\u003cli\u003eDo not open or dismantle the module housing.\u003c\/li\u003e\n\u003cli\u003eKeep the module in approved antistatic packaging before installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003ePre-Installation Inspection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInspect the module enclosure for physical damage.\u003c\/li\u003e\n\u003cli\u003eCheck the rear connector for bent or misaligned pins.\u003c\/li\u003e\n\u003cli\u003eDo not force the module into an incorrectly aligned chassis slot.\u003c\/li\u003e\n\u003cli\u003eDo not attempt to straighten damaged connector pins.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eModule Insertion\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm that the rear adapter unit is correctly installed and aligned.\u003c\/li\u003e\n\u003cli\u003eUse the release key to open the upper and lower ejector tabs.\u003c\/li\u003e\n\u003cli\u003eSlide the processor module into its designated controller chassis slot.\u003c\/li\u003e\n\u003cli\u003ePress the module firmly until the rear connector is fully seated.\u003c\/li\u003e\n\u003cli\u003eLock both ejector latches after completing the insertion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eActive and Standby Configuration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFollow the approved hot-swap procedure when installing a standby processor.\u003c\/li\u003e\n\u003cli\u003eAllow the standby module to complete initialization and synchronization.\u003c\/li\u003e\n\u003cli\u003eConfirm the Educated status indication before initiating a processor handover.\u003c\/li\u003e\n\u003cli\u003eVerify the health of both processor modules before changing their operating roles.\u003c\/li\u003e\n\u003cli\u003eDo not remove a processor while it is actively controlling the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 61508:\u003c\/strong\u003e Certified for applications up to SIL 3.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":53240102814059,"sku":"T8111C","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/T8111C_2.jpg?v=1784786611","url":"https:\/\/www.plcprotech.com\/products\/ics-triplex-t8111c-trusted-tmr-processor-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}