{"product_id":"inici03-abb-infi-net-to-infi-net-local-transfer-mod","title":"INICI03 ABB Infi-Net To Infi-Net Local Transfer Mod","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eINICI03\u003c\/strong\u003e Infi-Net to Infi-Net Local Transfer Module is a Harmony rack communication interface designed for the Symphony Enterprise Management and Control System. It serves as an intelligent bridge, providing a host computer or Human System Interface (HSI) with direct access to the Control Network (\u003cstrong\u003eCnet\u003c\/strong\u003e) or \u003cstrong\u003eINFI-NET\u003c\/strong\u003e communication system.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eINICI03\u003c\/strong\u003e is backward-compatible with existing \u003cstrong\u003eINFI 90 OPEN\u003c\/strong\u003e Strategic Enterprise Management Systems.\u003c\/p\u003e\n\n\u003cp\u003eThe complete interface assembly is a multi-module hardware system comprising three primary components:\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eINNIS01 Network Interface Module:\u003c\/strong\u003e Provides the intelligent front-end connection between the node and the communication network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eINICT03 Computer Transfer Module:\u003c\/strong\u003e Serves as the command-driven processing core for data buffering, point tables, and host interactions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIMMPI01 Multifunction Processor Interface Module:\u003c\/strong\u003e Provides the physical hardware interface for RS-232-C serial or SCSI parallel host connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Capacity Data Buffering:\u003c\/strong\u003e Dynamically packs and organizes process information and exception reports for efficient network transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Point Storage Capacity:\u003c\/strong\u003e The integrated \u003cstrong\u003eINICT03\u003c\/strong\u003e module can store up to 30,000 point definitions, depending on the point types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Data Integrity:\u003c\/strong\u003e Transmitted network frames use Cyclic Redundancy Check (CRC) codes and checksum verification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Power Recovery:\u003c\/strong\u003e Localized startup and shutdown procedures execute automatically following a power failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAsynchronous Processing:\u003c\/strong\u003e Local data buffering allows the host computer to poll data independently of the real-time \u003cstrong\u003eCnet\u003c\/strong\u003e clock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSymphony Enterprise Management and Control Systems\u003c\/li\u003e\n\u003cli\u003eINFI 90 OPEN DCS system integration\u003c\/li\u003e\n\u003cli\u003eCentral engineering and configuration stations using Composer tools\u003c\/li\u003e\n\u003cli\u003ePlant-wide Human System Interface workstations using Conductor NT or Conductor VMS\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProperty\u003c\/th\u003e\n\u003cth\u003eCharacteristic \/ Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB \/ Bailey Hartmann \u0026amp; Braun\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eINIIT03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eItaly (IT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStocked At\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eITABB004EXPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Order Quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIMMPI01 Power Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 VDC at 415 mA; 2.08 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eINICT03 Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e512 kbytes ROM; 2 Mbytes RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eINICT03 Power Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 VDC at 1.958 A; 9.8 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eINICT03 Communication Rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 to 19,200 baud through RS-232-C; 4 Mbytes\/sec through SCSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eINNIS01 Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 kbytes ROM; 208 kbytes RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eINNIS01 Power Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+5 VDC at 900 mA (4.5 W typical); +15 VDC at 5 mA (0.08 W typical); -15 VDC at 200 mA (3 W typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eINNIS01 Network Rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Mbaud or 2 Mbaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 62,500 total system nodes; up to 250 nodes per individual loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEach module occupies one slot in a standard Module Mounting Unit (MMU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 90% up to 55°C (131°F), noncondensing; 5% to 40% above 55°C (131°F), noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAtmospheric Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSea level to 3 km (1.86 mi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir Quality\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNoncorrosive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Protection:\u003c\/strong\u003e The modules contain components sensitive to electrostatic discharge. Personnel must wear a grounded wrist strap connected to the cabinet chassis ground before handling circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Address Configuration:\u003c\/strong\u003e Before installing modules in the Module Mounting Unit, configure the circuit-board DIP switches for the required node address, loop address, and loop operating mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Fault Timer:\u003c\/strong\u003e Do not operate the modules with the machine fault timer circuit manually disabled. Doing so may produce unpredictable output sequences and compromise loop safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Verify cabinet power-loading limits before installation. Insert each module into its designated card-cage slot and fully tighten both faceplate retaining screws.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668623913323,"sku":"INIIT03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-iniit03-infi-90-infi-net-to-infi-net-transfer-module-1etrqjpqswv_54d4e216-f412-479b-9f7b-897eccce6bc3.jpg?v=1765535906","url":"https:\/\/www.plcprotech.com\/products\/inici03-abb-infi-net-to-infi-net-local-transfer-mod","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}