{"product_id":"ioc16t-200-565-000-013-vibro-meter-input-output-card-for-vm600","title":"IOC16T 200-565-000-013 Vibro-Meter Input\/Output Card for VM600","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIOC16T 200-565-000-013 (IOC16T)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density input\/output communication card designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVibro-Meter VM600\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erack system. Functioning as the rear-panel interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emachinery protection card or as a standalone signal aggregator, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIOC16T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilitates the physical connection of up to 16 dynamic or quasi-static signals. It is primarily utilized in large-scale\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSI (Turbine Supervisory Instrumentation)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand condition monitoring applications where extensive sensor integration is required. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200-565-000-013\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a robust connection point for field wiring, ensuring signal integrity is maintained from the transducer to the digital processing environment of the VM600 backplane.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration (Deep Dive)\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200-565-000-013\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration is built for reliability in high-interference industrial environments, featuring specific I\/O routing for complex monitoring tasks.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard 4-channel I\/O cards, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIOC16T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehandles up to 16 channels, making it ideal for monitoring multiple bearings or large-scale auxiliary equipment in power plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Block Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with high-quality screw-terminal connectors that support secure field wiring and easy maintenance without disturbing the front-end processing cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt acts as a passive or active bridge (depending on configuration) that routes raw sensor data to the processing modules while providing buffered outputs for external analysis tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Circuitry:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes internal surge protection and EMI filtering to prevent transient voltage spikes from damaging the internal VM600 VME bus architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIOC16T 200-565-000-013\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibro-Meter (Meggitt)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSwitzerland\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Input\/Output Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCard Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRear-panel I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to 65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.48 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Terminal Blocks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6U Height, Single Slot Width\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IOC16T 200-565-000-013 be used with any VM600 card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIOC16T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically designed to pair with processing cards that require high-density I\/O. It is most commonly used in conjunction with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMC6\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules. Always verify the backplane compatibility in your specific rack configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I handle signal noise on the 16-channel inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure that the twisted-pair sensor cables are correctly landed on the differential input terminals. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIOC16T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides dedicated ground\/shield pins; these should be the only ground point for the cable shields to prevent the introduction of 50\/60 Hz noise.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this card hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, but with caution. While the physical interface can be disconnected, removing an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIOC16T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhile the machine is running will break the protection loop for all 16 channels, likely triggering a system-wide trip if not bypassed in the software first.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Sequence:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen wiring 16 channels, use a systematic labeling approach. Start from the bottom terminals and work upwards to ensure clear visibility and access. Use ferruled wire ends to prevent \"stray strands\" from short-circuiting adjacent high-density terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIOC16T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be inserted into the rear slot exactly corresponding to the front processing card. The DIN 41612 connectors are precise; ensure the card is perpendicular to the backplane before applying seating pressure to avoid pin damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn a fully loaded VM600 rack, 16-channel cards can contribute to cable bundle heat. Ensure sufficient clearance behind the rack for airflow and avoid tightly packing signal cables which can trap heat near the terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIOC16T 200-565-000-013\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis prized for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSpace-to-Channel Efficiency\u003c\/strong\u003e. By consolidating 16 channels into a single rear-slot footprint, it allows for significantly smaller rack configurations in crowded control rooms. Furthermore, its \"Transparent Signal Path\" ensures that the raw analog waveforms from proximity probes and accelerometers are delivered to the processing card with zero phase-shift and minimal attenuation, which is critical for accurate FFT and orbit analysis in turbine diagnostics.\u003c\/p\u003e","brand":"VIBRO-METER","offers":[{"title":"Default Title","offer_id":52695211770219,"sku":"VM600 IOC16T 200-565-000-013","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vibro-meter-vm600-ioc16t-200-565-000-013-input-output-card-d2zy2stpnk3_e585c391-b7f7-40fc-908e-4f6db81f3e0b.jpg?v=1766130852","url":"https:\/\/www.plcprotech.com\/products\/ioc16t-200-565-000-013-vibro-meter-input-output-card-for-vm600","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}