{"product_id":"kl3311-beckhoff-bus-terminal-1-channel-thermocouple-input","title":"KL3311 BECKHOFF Bus Terminal 1-Channel Thermocouple Input","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL3311 (KL3311)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision 1-channel analog input terminal designed for direct connection of thermocouples in complex industrial automation environments. Engineered by Beckhoff for the K-bus system, this module is indispensable in high-temperature monitoring applications such as glass manufacturing, metal processing, and power generation. By integrating advanced 2-wire technology and electrical isolation of 500 V, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL3311\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures signal integrity and prevents ground loops in noisy electromagnetic environments. Its ability to process a wide range of sensor types (J, K, L, B, E, N, R, S, T, U) makes it a versatile asset for maintaining thermal stability and reducing unplanned system downtime in critical PID control loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL3311\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a sophisticated 16-bit analog-to-digital conversion process to translate non-linear thermocouple voltages into precise temperature data. The module features internal cold-junction compensation, which eliminates the need for external reference junctions, thereby simplifying field wiring and reducing installation costs. Communication with the higher-level controller is handled via the Bus Coupler, where the process image can be configured for either 16-bit data or an optional 8-bit control\/status byte. This flexibility allows engineers to monitor sensor health, including \"wiring fail\" detection, ensuring that any open-circuit condition is immediately flagged to the PLC logic to prevent hazardous process excursions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKL3311\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBECKHOFF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGermany\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1-Channel Thermocouple (Types J, K, L, B, E, N, R, S, T, U)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDependent on sensor (Default Type K: -100 to +1370 deg C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 deg C per digit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConversion Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 200 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Error\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than +\/- 0.5 percent (Relative to full scale)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 V (K-bus to signal voltage)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e65 mA typical (from K-bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 12 mm x 100 mm x 68 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.07 kg (Shipping weight 2.0 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, ATEX, IECEx\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the KL3311 handle sensor breakage or disconnected wires?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module includes a \"Wiring Fail\" indication. If a thermocouple wire is broken or disconnected, the status bit in the process image is set, and the input data moves to a defined limit value, allowing the safety logic in the PLC to trigger an alarm or emergency shutdown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module measure millivolt signals without a thermocouple?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Beyond standard thermocouple types, the KL3311 can be configured for raw mV measurement within the ranges of +\/- 30 mV to +\/- 120 mV. This is particularly useful for custom sensors or specialized laboratory instrumentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs software configuration required for the KL3311?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe terminal operates with default settings (Type K) immediately. However, to change sensor types or adjust the process image (e.g., enabling control\/status bytes), configuration must be performed via the TwinCAT System Manager or the respective Bus Coupler.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCold Junction Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor optimal measurement accuracy, avoid installing heat-generating components (such as high-power motor starters or power supplies) directly below the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKL3311\u003c\/strong\u003e. Excessive ambient heat can create thermal gradients across the terminal contacts, affecting the internal cold-junction compensation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Noise Reduction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlthough the module is electrically isolated, always use compensated thermocouple cables (extension wires) for the entire run to the terminal. Ensure that the cable shield is grounded at the entry point of the control cabinet to minimize EMI interference on the low-voltage mV signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEx ec Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing in ATEX\/IECEx Zone 2 environments, the terminal must be housed in an enclosure providing at least IP54 protection. Ensure that the power is disconnected before plugging or unplugging the module to prevent spark risks in hazardous atmospheres.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106634981739,"sku":"KL3311","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/kl3311-mfknf21idwp.png?v=1776245157","url":"https:\/\/www.plcprotech.com\/products\/kl3311-beckhoff-bus-terminal-1-channel-thermocouple-input","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}