{"product_id":"kps-76-danfoss-060l310266-heavy-duty-thermostat","title":"KPS 76 Danfoss 060L310266 Heavy Duty Thermostat","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060L310266 (060L310266)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance KPS series industrial thermostat engineered for demanding monitoring and control applications. Primarily utilized in marine environments, power plants, and heavy industrial boiler systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKPS 76\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides reliable temperature regulation under extreme mechanical stress. This robust switch is designed to withstand high levels of vibration and shock, ensuring critical fail-safe operation in engine rooms and cooling water systems. By maintaining precise control within the 20 to 60 Celsius range, it serves as a vital safeguard against thermal runaway, significantly enhancing equipment longevity and operational safety in harsh industrial landscapes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060L310266\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware is built for durability and precision, featuring a mechanical design that prioritizes stability in high-vibration settings.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Regulation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit operates within a setpoint range of 20 to 60 Celsius, featuring a manually adjustable mechanical differential (hysteresis) between 3 and 14 Celsius for fine-tuned control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensing Element:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with a 2-meter capillary tube, allowing for remote sensing of fluids or gases while keeping the switch housing isolated from extreme point-of-measurement conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe sensor is designed to withstand maximum temperatures of up to 130 Celsius, providing a wide safety margin during system surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a high-integrity SPDT (Single Pole Double Throw) contact system, capable of handling inductive motor loads or triggering alarm circuits upon reaching the threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKPS 76 (060L310266)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHeavy Duty Thermostat\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSetting Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 to 60 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMechanical Differential\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 to 14 Celsius (Adjustable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Sensor Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCapillary Tube Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor Pocket Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e65, 75, 110, 160 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP67 (High Vibration Resistance)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I adjust the differential on the KPS 76?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe differential is adjusted via the internal setting screw. Increasing the differential prevents \"hunting\" (rapid cycling) of the controlled equipment, which is particularly useful in systems with high thermal inertia.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit suitable for outdoor or marine deck installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060L310266\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for the most grueling conditions. Its housing is resistant to sea air and high humidity, provided the electrical connections are sealed according to the IP67 specification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the capillary tube be shortened if it is too long?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The capillary tube and sensor bulb are a factory-sealed, pressurized system. Cutting or kinking the tube will result in immediate and permanent failure of the thermostat. Excess tubing should be carefully coiled and secured.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the KPS series is vibration-resistant, it is best practice to mount the switch housing on a stable surface. If the sensing point is on a high-vibration engine block, utilize the 2-meter capillary to mount the main switch body on a nearby bulkhead or frame to further extend the service life of the internal contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Pocket Selection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure accurate thermal transfer, the sensor bulb must be fully immersed in the medium. Select a sensor pocket (65 mm to 160 mm) that places the bulb in the active flow of the pipe, rather than in a stagnant \"dead zone.\" The use of thermal conductive paste inside the pocket is recommended to decrease response time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen switching high-inductive loads, such as large solenoid valves or motors, the use of an external RC snubber or contactor is advised to protect the internal silver contacts from arcing and premature wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102418493803,"sku":"KPS77 060L310266","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/kps77060l310266-actu2fhjqpl.png?v=1776137770","url":"https:\/\/www.plcprotech.com\/products\/kps-76-danfoss-060l310266-heavy-duty-thermostat","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}