{"product_id":"lenze-e82ev152_2b-8200-series-vector-variable-frequency-drive","title":"Lenze E82EV152_2B 8200-Series Vector Variable Frequency Drive","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLenze E82EV152_2B (E82EV152_2B)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance vector-controlled variable frequency drive (VFD) engineered for the 8200-series platform. Designed to provide superior motor control in industrial automation environments, this drive delivers a rated power output of 1.1 kW in 230 VAC applications. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE82EV152_2B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexcels in environments such as small-scale conveyor systems, industrial pumps, and packaging machinery where precise speed regulation and high starting torque are essential. Its panel-mount design allows for rapid integration into control cabinets, significantly simplifying the commissioning process. By utilizing advanced vector control algorithms, this drive minimizes energy consumption and enhances the operational lifespan of connected motors, making it a reliable solution for maintenance teams tasked with sustaining consistent production output.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe drive utilizes a sophisticated hardware architecture designed for reliability in demanding production cycles. It supports robust torque-to-speed curves, ensuring steady performance even during fluctuating load conditions. The unit is optimized for 50 Hz grid environments and is built with high-quality power transistors that provide efficient current handling while maintaining minimal thermal dissipation. The internal circuitry is shielded against common electromagnetic interference (EMI) prevalent in factory settings, ensuring that communication between the drive and external control systems remains stable. Its modular design promotes simplified wiring and maintenance, allowing for quick diagnosis of drive status via front-mounted diagnostic ports.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE82EV152_2B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLenze\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8200-series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVariable frequency drives\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAlternate Part Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE82EV152K2B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.1 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.01 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30.00 x 15.00 x 20.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLifecycle Status\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhase-Out\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommodity Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85044095\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the E82EV152_2B suitable for applications requiring high starting torque?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 8200 Vector technology provides excellent torque control at low speeds, making it suitable for applications that demand consistent start-up force under load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the panel mount design facilitate installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit features integrated mounting points that allow it to be directly secured within a cabinet backplane. This reduces the need for custom brackets and ensures optimal alignment for air cooling within the enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be used as a replacement for older 8200 units?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the E82EV152_2B is the factory-specified replacement for existing installations using the 8200 series, ensuring full parameter compatibility and electrical fitting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it necessary to use external filters with this drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDepending on the cable length and the presence of sensitive electronics nearby, we recommend checking the local EMC guidelines for your cabinet. The drive has built-in filtering, but additional line reactors are advised if you are operating in a high-noise environment.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Operational Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite its compact 1.01 kg design, the drive requires adequate vertical airflow to dissipate heat. Ensure at least 10 cm of clearance is maintained above and below the unit. Do not install the drive directly above other heat-generating components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Standards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse shielded motor cables to mitigate high-frequency radiated noise. Ensure that the cable shield is grounded at both the drive end and the motor terminal box using a 360-degree clamp to maximize EMI protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore performing any maintenance or wiring, ensure the supply power is disconnected and allow at least 5 minutes for the internal DC bus capacitors to discharge. Confirm the absence of hazardous voltage at the DC bus terminals using a calibrated multimeter before touching the connection points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105058382187,"sku":"E82EV152_2B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82ev152-2b-4ydaddwejem.png?v=1776235785","url":"https:\/\/www.plcprotech.com\/products\/lenze-e82ev152_2b-8200-series-vector-variable-frequency-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}