{"product_id":"lenze-e82zafac010-8200-vector-series-application-i-o-module","title":"Lenze E82ZAFAC010 8200 Vector Series Application I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLenze E82ZAFAC010 (E82ZAFAC010)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability Application I\/O PT module engineered specifically for the 8200 Vector inverter series. Designed to extend the control capabilities of industrial drives, this module provides the necessary interface points for advanced input and output signal management in automated manufacturing systems. By facilitating seamless communication between the inverter and peripheral field devices, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE82ZAFAC010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables precise process control in demanding environments such as material handling, pump systems, and conveyor lines. Its robust construction ensures consistent performance, allowing maintenance engineers to minimize system latency and maximize uptime in critical production cycles where signal accuracy and reliable connectivity are paramount.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe hardware architecture of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE82ZAFAC010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for compact integration within the 8200 Vector drive ecosystem. The module serves as an expansion interface that allows for the addition of supplemental analog and digital I\/O points, directly enhancing the flexibility of the host drive's control logic. It utilizes standard connection interfaces that ensure a secure, noise-resistant link between the drive and external sensors or PLC controllers. The design focuses on operational efficiency, featuring low power consumption and high thermal stability, which allows it to function reliably within the confined spaces of an industrial control cabinet without requiring additional cooling measures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eE82ZAFAC010\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLenze\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8200-series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApplication I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.11 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.10 x 7.60 x 2.50 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLifecycle Status\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhase-Out\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDrive-integrated plug-in\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommodity Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85371091\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the E82ZAFAC010 compatible with all 8200 Vector drive variants?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the module is designed as a standardized expansion component for the 8200 Vector series. Ensure that your inverter firmware supports the I\/O expansion features provided by this specific module version.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of this module in an automation system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides additional I\/O capacity, allowing the inverter to process more digital or analog feedback signals from the field, which is essential for complex automation tasks that require more inputs than the base drive provides.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions should be taken when installing the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlways ensure the drive is powered down and the internal bus voltage has fully discharged before inserting or removing the I\/O module. Static discharge can damage the internal circuitry; utilize appropriate ESD protection during handling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the phase-out status mean this part is no longer recommended?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe phase-out status reflects the manufacturer's lifecycle management. The component remains the correct and standard replacement for existing 8200-series installations, and original stock is fully functional for ongoing maintenance requirements.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Operational Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen inserting the module into the host drive, ensure the connector pins are correctly aligned and firmly seated. Avoid using excessive force, as this can bend the pins and cause signal intermittency or permanent failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo maintain signal integrity, route all I\/O cabling away from high-voltage power lines and motor output cables. Use shielded, twisted-pair wiring for all analog signals to prevent electromagnetic noise from causing jitter or false readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the module is built for industrial settings, it should be housed in an enclosure that protects it from liquid ingress, excessive dust, and conductive particles that could bridge the signal terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105058709867,"sku":"E82ZAFAC010","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82zafac010-0d0nlp44a5e.png?v=1776235937","url":"https:\/\/www.plcprotech.com\/products\/lenze-e82zafac010-8200-vector-series-application-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}