{"product_id":"lenze-e82zafpc010-8200-series-communication-module","title":"Lenze E82ZAFPC010 8200-series Communication Module","description":"\u003ch1\u003eLenze E82ZAFPC010 8200-series Communication Module\u003c\/h1\u003e\n\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eIntegration of frequency inverters into centralized fieldbus networks is simplified using the \u003cstrong\u003eE82ZAFPC010\u003c\/strong\u003e PROFIBUS DP communication function module. Engineered specifically for the Lenze \u003cstrong\u003e8200-series\u003c\/strong\u003e frequency inverters, this pluggable interface module enables high-speed cyclic data exchange between a master PLC or host controller and the drive system. By establishing a reliable digital communication link, the module allows for precise control, parameterization, and real-time diagnostics of the connected drive, reducing wiring complexity and improving overall system response times.\u003c\/p\u003e\n\n\u003cp\u003eThis communication module mounts directly onto the front interface slot of the inverter, drawing its control power directly from the host drive. It supports standard PROFIBUS DP transmission rates and integrates seamlessly into existing industrial control architectures, making it a critical component for maintaining or upgrading legacy automation networks.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned for seamless mechanical and electrical integration with Lenze 8200-series vector inverters.\u003c\/li\u003e\n  \u003cli\u003eSupports standard PROFIBUS DP communication protocol for high-speed cyclic data transfer.\u003c\/li\u003e\n  \u003cli\u003ePluggable architecture allows for rapid installation, configuration, and field replacement.\u003c\/li\u003e\n  \u003cli\u003eDirect bus connection reduces hardwired control lines and simplifies diagnostic troubleshooting.\u003c\/li\u003e\n  \u003cli\u003ePowered directly via the drive's internal interface slot, eliminating the need for external auxiliary power supplies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFactory automation and centralized machine control networks.\u003c\/li\u003e\n  \u003cli\u003eConveyor systems and material handling applications requiring synchronized drive control.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and production lines integrated via PROFIBUS DP networks.\u003c\/li\u003e\n  \u003cli\u003eWater treatment and HVAC systems utilizing distributed drive architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eParameter\u003c\/strong\u003e\n      \u003cstrong\u003eValue\u003c\/strong\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eLenze\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\/Model\u003c\/td\u003e\n      \u003ctd\u003eE82ZAFPC010\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003e8200-series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eCommunication Function Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n      \u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Phase\u003c\/td\u003e\n      \u003ctd\u003ePhase-Out\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.10 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n      \u003ctd\u003e5.10 cm x 7.60 cm x 2.50 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCommodity Code\u003c\/td\u003e\n      \u003ctd\u003e85044095\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure safe and reliable operation, adhere to the following installation procedures:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Isolation:\u003c\/strong\u003e Disconnect all electrical power from the frequency inverter and wait for the internal DC-bus capacitors to fully discharge before mounting or removing the communication module.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Carefully align the module's connector pins with the interface slot on the front of the 8200-series inverter. Press firmly until the module is fully seated, and secure any integrated retaining screws to ensure solid grounding.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Use only approved, high-quality shielded twisted-pair cables specified for PROFIBUS DP networks. Ensure the cable shield is grounded at both ends to prevent electromagnetic interference (EMI) from disrupting data transmission.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBus Termination:\u003c\/strong\u003e Ensure that proper bus termination resistors are activated or installed at the first and last physical nodes of the PROFIBUS network segment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105047667051,"sku":"E82ZAFPC010","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e82zafpc010-1ydszdbcdu1.png?v=1776236004","url":"https:\/\/www.plcprotech.com\/products\/lenze-e82zafpc010-8200-series-communication-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}