{"product_id":"lenze-e94ashe0134-9400-series-servo-drive","title":"Lenze E94ASHE0134 9400-Series Servo Drive","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eLenze E94ASHE0134 (E94ASHE0134)\u003c\/strong\u003e is a high-performance single-axis servo drive from the 9400-Series, engineered for precise motion control in sophisticated industrial automation. Rated for a power output of 5.5 kW, this drive is designed to handle high-dynamic applications—such as robotics, multi-axis machine tools, and complex packaging systems—where precision and rapid response times are mandatory. Its scalable architecture allows it to fit seamlessly into environments requiring integrated safety and complex synchronization, significantly reducing downtime through advanced diagnostic and fault-monitoring capabilities.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 9400-Series is built on a modular design principle, allowing for deep integration into various fieldbus-based automation networks.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Motion Control:\u003c\/strong\u003e The E94ASHE0134 supports sophisticated motion profiles, including electronic camming and multi-axis synchronization, which are essential for high-precision manufacturing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Versatility:\u003c\/strong\u003e The drive supports various fieldbus interfaces via plug-in modules, including Ethernet, Powerlink, Profinet, and Profibus. This ensures future-proof connectivity with most industry-standard PLCs and controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Integrated:\u003c\/strong\u003e The series offers optional safety functions (Safe Torque Off), allowing for compliant machine design without the need for additional contactors or mechanical safety hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Efficiency:\u003c\/strong\u003e Optimized power stage design reduces thermal losses during operation, contributing to higher overall system energy efficiency and lower cooling requirements within the control cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eE94ASHE0134\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eLenze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eRange\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e9400-series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eType\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eServo Drives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eRated Power\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e180 - 550 V AC (3-Phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e8.10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eCommodity Code\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e85044095\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eOperational Status\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the E94ASHE0134 support standard Ethernet communication protocols?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 9400-Series supports Ethernet-based communication through the use of specific communication modules. You should verify the specific module requirement based on your network architecture (e.g., Profinet vs. EtherCAT).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive be used for safety-critical applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 9400-Series is designed to support integrated safety functions. However, the specific safety level depends on the hardware configuration and the safety modules installed. Always ensure that safety systems are certified to your local regulatory requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the drive configured and parameterized?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe drive is configured using the Lenze engineering software suite. This allows for parameterization, commissioning, and detailed diagnostic monitoring of motion profiles via a PC connection to the drive's communication port.\u003c\/p\u003e\n\u003ch3\u003eEngineering Integration and Operational Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding Requirements:\u003c\/strong\u003e Due to the high-speed switching frequencies used in 9400-Series servo drives, proper EMC shielding is vital. Use only shielded motor cables with a 360-degree connection to the PE ground at the drive entrance to mitigate high-frequency interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Cooling:\u003c\/strong\u003e With a rated output of 5.5 kW, ensure that the control cabinet is sized for adequate airflow. Mount the drive vertically with at least 100 mm of clearance above and below the unit to allow for unimpeded heat dissipation from the integrated heatsinks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Bus Sharing:\u003c\/strong\u003e The 9400-Series supports DC bus sharing for multi-axis configurations. When implementing this, ensure that the common DC bus is properly fused and that total regenerative energy is managed by a centralized braking resistor or a feed-in\/regenerative power supply module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Commissioning:\u003c\/strong\u003e Always perform a dry-run test without the motor load coupled to the mechanical system during the initial commissioning phase to verify motion direction and limit switch logic.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105055498603,"sku":"E94ASHE0134","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/e94ashe0134-42bxbidpr0b.png?v=1776236136","url":"https:\/\/www.plcprotech.com\/products\/lenze-e94ashe0134-9400-series-servo-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}