{"product_id":"lenze-evf8216-e-8200-series-variable-frequency-drive","title":"Lenze EVF8216-E 8200-Series Variable Frequency Drive","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eLenze EVF8216-E (EVF8216-E)\u003c\/strong\u003e is a high-reliability variable frequency drive developed for steady-state motor control in heavy-duty industrial processing. As a cornerstone of the 8200-series range, this inverter provides precise frequency and voltage modulation, enabling optimized speed and torque control for applications such as pump systems, conveyor drives, and fan regulation. By facilitating controlled motor ramps, the EVF8216-E protects mechanical components from high-current start-up surges, thereby extending the operational lifespan of both the motor and the driven load in critical manufacturing environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe EVF8216-E is designed to integrate into complex control architectures, offering both standalone operational flexibility and compatibility with modular I\/O expansion.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Utilizes advanced V\/f control algorithms to maintain consistent performance across a wide speed range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Control:\u003c\/strong\u003e The drive accepts standard analog and digital signals, allowing for seamless integration with PLC-based automation systems or manual potentiometer speed adjustment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Architecture:\u003c\/strong\u003e Features comprehensive internal monitoring, including protection against overvoltage, undervoltage, and thermal overload, ensuring the drive enters a safe state during fault conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Design:\u003c\/strong\u003e Supports the installation of 8200-series function modules, enabling the addition of fieldbus communication or enhanced I\/O capability to meet evolving production requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eEVF8216-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eLenze\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eRange\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e8200-series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eType\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eVariable frequency drives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eItem Code\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e33.8216_E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e4.90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e12.70 x 25.40 x 22.90 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eOperational Status\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003ePhase-Out\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the EVF8216-E still supported for new system installations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the EVF8216-E is in the \"Phase-Out\" stage, it remains a highly effective solution for maintaining and extending the life of existing industrial machinery where a full system migration is not yet feasible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"33.8216_E\" item code?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis is the internal manufacturer part reference used to distinguish specific production variants within the 8200-series. Always verify this code against your original unit's nameplate to ensure exact hardware matching.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this drive handle external electromagnetic interference?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit is designed for standard industrial use; however, best practice dictates the use of shielded motor cabling and external line filters if installed in environments with high levels of electrical noise or sensitive instrumentation.\u003c\/p\u003e\n\u003ch3\u003eEngineering Integration and Safety Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management:\u003c\/strong\u003e The EVF8216-E relies on efficient convection cooling. Ensure the drive is mounted vertically in the control cabinet with a minimum clearance of 100 mm above and below the unit. Avoid mounting the drive in proximity to other heat-generating components to prevent premature thermal derating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Standards:\u003c\/strong\u003e Use properly sized conductors for the input power supply to accommodate the drive's peak current demand. All control signal wiring must be separated from motor output cables by at least 200 mm to prevent inductive cross-talk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe Commissioning:\u003c\/strong\u003e Prior to applying full voltage, conduct a resistance check on the motor circuit to rule out phase-to-ground shorts. Ensure that all parameter settings (e.g., motor current, min\/max frequency) are correctly configured via the keypad or software interface before engaging the run signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance Note:\u003c\/strong\u003e Given the drive's mature product cycle, inspect the internal cooling fan periodically for dust accumulation. If the fan exhibits signs of bearing failure, replace it immediately to prevent internal overheating and potential failure of the power stack.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105055400299,"sku":"EVF8216-E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evf8216-e-ezmfzesxie5.png?v=1776236432","url":"https:\/\/www.plcprotech.com\/products\/lenze-evf8216-e-8200-series-variable-frequency-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}