{"product_id":"lenze-evf8245-e-8200-series-tiway-network-host-adapter","title":"Lenze EVF8245-E 8200-Series Tiway Network Host Adapter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLenze EVF8245-E (EVF8245-E)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized network host adapter designed to interface with the 8200-series drive ecosystem via the Tiway communication protocol. Functioning as a critical gateway for industrial data exchange, this adapter is engineered to support 110 VAC supply environments, providing robust connectivity for servo-driven automation tasks. In industries such as automotive assembly and heavy manufacturing, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEVF8245-E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the vital link between central control systems and localized drive networks, ensuring reliable command propagation and feedback monitoring. By utilizing RS232 communication pathways, it allows engineers to manage complex network configurations effectively, reducing system latency and maintaining the integrity of high-speed production line control.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe hardware architecture of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEVF8245-E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically optimized for integration within the 8200-series controller range. It utilizes a sophisticated communication interface that bridges legacy Tiway network requirements with modern drive control expectations. The device is built for durability, featuring a shielded internal layout to mitigate the effects of electromagnetic interference common in high-power drive cabinets. The unit supports streamlined data transmission, enabling real-time status updates and parameter adjustments across the network. Its design allows for straightforward integration into existing cabinet layouts, ensuring that critical network connectivity is maintained without requiring extensive hardware modifications or signal degradation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEVF8245-E\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLenze\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8200-series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTiway Network Host Adapter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAlternate Part Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e33.8245_E\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS232 \/ Tiway\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.40 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.20 x 35.60 x 25.40 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLifecycle Status\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhase-Out\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommodity Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85044095\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the EVF8245-E compatible with existing Tiway network infrastructures?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, this adapter is designed as the native host gateway for the 8200-series Tiway networks. It ensures direct compatibility with existing host-to-drive communication protocols.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit handle the high-noise environment of a servo cabinet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit is built with high-quality components and shielding specifically for the industrial electrical industry. When properly grounded via the chassis, it maintains stable RS232 signal integrity despite high-power switching noise in the surrounding cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is this product classified as Phase-Out?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe phase-out classification indicates a transition in the product lifecycle management. It does not affect the performance or reliability of the hardware; we maintain original stock to ensure ongoing support for legacy production systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I check if network communication is lost?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirst, verify the 110 VAC input and the integrity of the RS232 serial cable connections. Inspect the status LEDs on the front panel for error patterns, which can indicate if the issue is a physical layer failure or a protocol-level mismatch.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Operational Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProper Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo ensure reliable network communication and protect sensitive serial ports, ensure the chassis of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEVF8245-E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis connected to a low-impedance protective earth (PE) point within the control cabinet. Use a wide-braid ground strap for high-frequency noise mitigation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute the RS232 communication cables away from high-current motor leads and AC power lines to prevent signal crosstalk. If routing parallel paths is unavoidable, maintain a minimum separation distance of 20 cm and use shielded cable types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePreventive Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePeriodically check the terminal block connections for signs of vibration-induced loosening. Given the weight of 6.40 kg, ensure the unit is securely mounted to a rigid DIN rail or backplate to prevent structural stress on the mounting points over time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Lenze","offers":[{"title":"Default Title","offer_id":53105058611563,"sku":"EVF8245-E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/evf8245-e-lgaijar1jqv.png?v=1776236456","url":"https:\/\/www.plcprotech.com\/products\/lenze-evf8245-e-8200-series-tiway-network-host-adapter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}