{"product_id":"mbs-3000-060g1121-danfoss-low-pressure-transmitter","title":"MBS 3000 060G1121 Danfoss Low Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1121 (060G1121)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision-engineered low-pressure transmitter within the high-performance Danfoss MBS 3000 series. Designed for high-accuracy measurement in ranges from 0 - 1 bar, this sensor is a staple in HVAC systems, tank level monitoring, and low-pressure pneumatic circuits. By converting gauge pressure into a stable 4 - 20 mA analog output, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1121\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for granular control over sensitive industrial processes. Its robust stainless steel housing and excellent vibration stability make it a reliable choice for demanding environments such as power plants and chemical processing facilities, where maintaining specific pressure thresholds is critical to preventing system failures and ensuring operational safety.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 060G1121 model code identifies the following technical configurations:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e060G\u003c\/strong\u003e: Commercial prefix for the Danfoss industrial sensor portfolio.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Indicates the specific low-pressure measuring range of 0 to 1 bar.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Specifies Gauge (relative) pressure reference, measuring against ambient atmosphere.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Industry-standard 4 - 20 mA output signal for long-distance transmission with low noise interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1\u003c\/strong\u003e: Electrical connection via a Plug Pg 9 (EN 175301-803-A), providing a secure and replaceable interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAB04\u003c\/strong\u003e: Mechanical connection utilizing the G 1\/4 A (EN 837) thread standard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e060G1121\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDenmark \/ EU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 - 1 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Reference\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGauge (Relative)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Signal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9 - 32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePressure Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG 1\/4 A (EN 837)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug Pg 9 (EN 175301-803)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.5 percent FS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel (AISI 316L)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 060G1121 be used for vacuum measurement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1121\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis calibrated for 0 - 1 bar gauge pressure. While it can physically withstand a vacuum, it is not designed to provide accurate linear output for negative pressure values. For vacuum applications, a dedicated vacuum or compound range transmitter should be selected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this model suitable for media temperatures exceeding 85 deg C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe standard operating limit is 85 deg C. If your process media exceeds this, it is highly recommended to use a syphon tube or a long capillary to dissipate heat before the media reaches the sensor diaphragm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the power supply polarity is accidentally reversed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 060G1121 includes integrated reverse polarity protection. This prevents damage to the internal electronics if the loop wiring is incorrectly connected during commissioning.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eLow-Pressure Accuracy \u0026amp; Venting:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSince the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1121\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a gauge pressure transmitter in a low-pressure range (1 bar), accuracy is highly dependent on proper atmospheric venting. Ensure that the Pg 9 plug and the cable used do not completely hermetically seal the reference port. The internal venting mechanism must be able to \"breathe\" to account for changes in local barometric pressure, which could otherwise cause a zero-point shift in such a sensitive range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Shielding:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor optimal performance, use a shielded cable for the 2-wire 4 - 20 mA loop. In 0 - 1 bar applications, even minor electromagnetic interference (EMI) can represent a significant percentage of the total measured range. Connect the shield to the ground terminal of the PLC or DCS, ensuring it is not grounded at the sensor end to avoid potential ground loop currents that could distort the pressure reading.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102381826411,"sku":"060G1121","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g1121-j0gsqladyc0.png?v=1776136911","url":"https:\/\/www.plcprotech.com\/products\/mbs-3000-060g1121-danfoss-low-pressure-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}