{"product_id":"mbs-3000-3811-1ab04-danfoss-060g1110-pressure-transmitter","title":"MBS 3000-3811-1AB04 Danfoss 060G1110 Pressure Transmitter","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1110 (060G1110)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDanfoss\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMBS 3000 series pressure transmitter, specifically engineered for high-pressure industrial applications. Designed to operate in the most demanding environments, such as hydraulic power units, water treatment high-pressure pumps, and industrial engine testing, this transmitter converts physical pressure into a stable electrical signal. With a measuring range of 0 to 600 bar, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMBS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the precision required for high-tonnage machinery and power protection systems. Its robust design is optimized to resist vibration and thermal shocks, ensuring critical system data remains accurate, thereby preventing over-pressure conditions and extending the operational life of hydraulic components.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe hardware architecture of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e060G1110\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for extreme durability and standard industrial integration.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensing Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing a gauge (relative) pressure reference, the unit provides accurate 0 to 600 bar measurement relative to atmospheric pressure, ideal for high-pressure hydraulic circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFeatures a standard 4 - 20 mA analog output, offering high noise immunity and long-distance transmission capability for direct connection to PLC or DCS analog input modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with a G 1\/4 A (EN 837) pressure connection, a standard industrial thread that ensures a leak-proof seal in high-pressure manifolds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUses a Plug Pg 9 (EN 175301-803-A) connector, allowing for rapid field replacement and a high degree of protection against dust and moisture ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal sensing element is designed for compatibility with a wide range of industrial media, including oils and non-corrosive gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMBS 3000 - 3811 - 1 AB04\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDanfoss\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e060G1110\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMeasuring Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 600 bar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Reference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGauge (Relative)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 - 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePressure Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG 1\/4 A (EN 837)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlug Pg 9 (EN 175301-803)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow should the 060G1110 be protected against pressure spikes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn hydraulic systems where water hammer or sudden pressure surges occur, it is highly recommended to install a Danfoss pulse snubber at the G 1\/4 A connection. This prevents the high-frequency 600 bar spikes from damaging the internal sensing diaphragm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this transmitter be used in outdoor environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, when the Pg 9 plug is correctly installed with its gasket and tightened, the unit achieves an IP65 rating. This provides sufficient protection against rain and splashing water, making it suitable for outdoor industrial installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 060G1110 require periodic calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the MBS 3000 series is laser-calibrated at the factory for life-long stability, industrial standards typically suggest a verification check every 12 to 24 months to ensure the 4 - 20 mA loop remains within the specified tolerance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSealing and Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen installing the G 1\/4 A connection, ensure the use of a suitable copper or bonded seal washer. Over-torquing can distort the pressure port, while under-torquing may lead to high-pressure leaks which are hazardous in 600 bar systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoop Power Considerations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 4 - 20 mA output is a 2-wire loop. Ensure the DC power supply (typically 24 VDC) is stable. If the cable run exceeds 100 meters, account for the voltage drop across the wire to ensure the transmitter still receives at least 9 VDC at full 20 mA output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf the transmitter is mounted directly on a high-vibration pump or engine, use a flexible capillary tube between the pressure source and the transmitter. This mechanical isolation protects the internal electronics from fatigue and ensures signal stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":53102418297195,"sku":"060G1110","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/060g1110-zjmzdhwfw3o.png?v=1776136910","url":"https:\/\/www.plcprotech.com\/products\/mbs-3000-3811-1ab04-danfoss-060g1110-pressure-transmitter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}