{"product_id":"mitsubishi-electric-fr-a820-1-5k-freqrol-a800-variable-frequency-drive","title":"Mitsubishi Electric FR-A820-1.5K FREQROL-A800 Variable Frequency Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eTo manage demanding motor control challenges in modern production environments, the \u003cstrong\u003eFR-A820-1.5K\u003c\/strong\u003e variable frequency drive from the Mitsubishi Electric \u003cstrong\u003eFREQROL-A800\u003c\/strong\u003e series provides highly adaptable vector control performance. Configured for three-phase 200V class operations, this inverter supports multiple operating duty ratings (SLD, LD, ND, HD) to match specific torque and load characteristics. Integrating advanced magnetic flux vector control alongside real sensorless vector control, it achieves high precision speed and torque regulation without requiring physical speed encoders under standard operations.\u003c\/p\u003e\n\n\u003cp\u003eThe unit features versatile communication capabilities, permitting integration with network topologies like CC-Link, CC-Link IE Field, DeviceNet, PROFIBUS-DPV0, and Modbus RTU. Designed for longevity and reliable deployment, it contains built-in diagnostic and protection circuits that prevent damage from overcurrent, overvoltage, and thermal overloads, ensuring operational continuity in harsh environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMulti-Rating Architecture:\u003c\/strong\u003e Supports Super Light Duty (SLD), Light Duty (LD), Normal Duty (ND), and Heavy Duty (HD) configurations to optimize performance for varied load profiles.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Control Algorithms:\u003c\/strong\u003e Selectable V\/F control, advanced magnetic flux vector control, real sensorless vector control, and PM sensorless vector control.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Protection Suite:\u003c\/strong\u003e Protection against overcurrent, regenerative overvoltage, motor overload, fin overheating, input\/output phase loss, and short circuits.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Carrier Frequency PWM:\u003c\/strong\u003e Employs Soft-PWM control to minimize acoustic motor noise and optimize operating efficiency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtensive Dynamic Interfacing:\u003c\/strong\u003e Equipped with 12 contact inputs, 5 open collector outputs, 2 relay outputs, and dual analog inputs for versatile system mapping.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePumping and industrial water management systems\u003c\/li\u003e\n  \u003cli\u003eConveyors, material handling, and logistics machinery\u003c\/li\u003e\n  \u003cli\u003eIndustrial fans, blowers, and HVAC systems\u003c\/li\u003e\n  \u003cli\u003eMachine tool axes and general packaging equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFR-A820-1.5K\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSeries Name\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFREQROL-A800\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Phase\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eThree-phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRated Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e200 to 240 V AC (50 Hz \/ 60 Hz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e170 to 264 V AC (50 Hz \/ 60 Hz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Tolerance Variation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e+\/-5%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNormal Duty (ND) Rated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNormal Duty (ND) Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.0 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSuper Light Duty (SLD) Rated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.2 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSuper Light Duty (SLD) Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10.5 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLight Duty (LD) Rated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.2 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLight Duty (LD) Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.6 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeavy Duty (HD) Rated Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.75 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeavy Duty (HD) Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.0 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.2 to 590 Hz (Limits to 400 Hz for Vector and PM Sensorless vector modes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Setting Resolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAnalog: 0.015 Hz \/ 60 Hz (or 0.03 Hz \/ 60 Hz depending on terminal selection); Digital: 0.01 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCooling Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eForced air cooling\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Structure\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eClosed type (IP20), JEM 1030 compliant\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-10 to +50 degC for LD, ND, HD (no freezing); -10 to +40 degC for SLD (no freezing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAmbient Operating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95% RH or less with substrate coating; 90% RH or less without substrate coating (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.3 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.3 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Name\u003c\/th\u003e\n      \u003cth\u003eType \/ Specification\u003c\/th\u003e\n      \u003cth\u003eFunctional Assignment\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTerminals 2, 4\u003c\/td\u003e\n      \u003ctd\u003eAnalog Input\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 V, 0 to 5 V, or 4 to 20 mA (selectable) frequency setting signals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTerminal 1\u003c\/td\u003e\n      \u003ctd\u003eAuxiliary Analog Input\u003c\/td\u003e\n      \u003ctd\u003e-10 to +10 V, -5 to +5 V auxiliary frequency setting signal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eContact Inputs\u003c\/td\u003e\n      \u003ctd\u003e12 Points (Digital)\u003c\/td\u003e\n      \u003ctd\u003eProgrammable multi-speed selection, jog operation, start signals, and reset commands\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePulse Train Input\u003c\/td\u003e\n      \u003ctd\u003e1 Point (100 kpps max)\u003c\/td\u003e\n      \u003ctd\u003eExternal pulse-train-driven speed reference command\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOpen Collector Outputs\u003c\/td\u003e\n      \u003ctd\u003e5 Points\u003c\/td\u003e\n      \u003ctd\u003eSelectable output signals (during run, frequency detection, overload alarm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelay Outputs\u003c\/td\u003e\n      \u003ctd\u003e2 Points\u003c\/td\u003e\n      \u003ctd\u003eFault\/alarm output contacts and status monitoring indications\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePulse Train Output\u003c\/td\u003e\n      \u003ctd\u003e1 Point (50 kpps max)\u003c\/td\u003e\n      \u003ctd\u003eProportional monitoring frequency output pulse train\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Position:\u003c\/strong\u003e Install the inverter vertically onto a flat, vertical surface using M4 or M5 mounting screws to ensure proper performance of the cooling fan assembly.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeat Dissipation Clearances:\u003c\/strong\u003e Maintain at least 50 mm clearance on both sides and a minimum of 100 mm clearance above and below the unit to prevent thermal blockages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVibration and Shock:\u003c\/strong\u003e Ensure the mounting site exhibits vibrational forces below 5.9 m\/s² (10 to 55 Hz in X, Y, and Z directions).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Line Protection:\u003c\/strong\u003e Install appropriate circuit breakers or fast-acting fuses upstream from the R\/L1, S\/L2, and T\/L3 power inputs to guard against short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102300627307,"sku":"FR-A820-1.5K","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FR-A820-1.5K-tycvbmxojag.png?v=1776137434","url":"https:\/\/www.plcprotech.com\/products\/mitsubishi-electric-fr-a820-1-5k-freqrol-a800-variable-frequency-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}