{"product_id":"mitsubishi-electric-fr-e740-5-5k-inverter-drive","title":"Mitsubishi Electric FR-E740-5.5K Inverter Drive","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOperating as a high-performance variable frequency control solution, the \u003cstrong\u003eFR-E740-5.5K\u003c\/strong\u003e digital inverter drive regulates three-phase AC induction motors up to 5.5 kW. This unit is engineered for precision speed and torque control in automated industrial environments, combining a space-saving footprint with advanced motor control algorithms. It delivers reliable performance across variable torque and constant torque applications, facilitating smooth acceleration and deceleration curves.\u003c\/p\u003e\n\u003cp\u003eTo support integration within networked manufacturing architectures, this unit features built-in serial communication capabilities and supports connection to various standard PLC and HMI control configurations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAdvanced sensorless vector control for enhanced torque performance at low speeds.\u003c\/li\u003e\n  \u003cli\u003eIntegrated RS-232, RS-422, and RS-485 serial communication protocols.\u003c\/li\u003e\n  \u003cli\u003eCompact installation envelope designed to optimize space inside control enclosures.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in diagnostic systems to monitor operation and protect against electrical fault conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMaterial handling and conveyor systems\u003c\/li\u003e\n  \u003cli\u003ePumping, fan, and blower regulation\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and food processing lines\u003c\/li\u003e\n  \u003cli\u003eMachine tool axes and textile manufacturing machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFR-E740-5.5K\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eInverter Drive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApplicable Motor Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.5 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Voltage Class\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eThree-phase 400 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Phase\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eThree-phase\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Capacity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.1 kVA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRS-232, RS-422, RS-485\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the unit vertically on a flat, non-flammable backplate to facilitate correct convective airflow.\u003c\/li\u003e\n  \u003cli\u003eMaintain specified physical clearance zones above, below, and to the sides of the chassis for heat dissipation.\u003c\/li\u003e\n  \u003cli\u003eEnsure all input power connections are exclusively terminated at R\/L1, S\/L2, and T\/L3 to prevent catastrophic hardware damage.\u003c\/li\u003e\n  \u003cli\u003eApply correct grounding techniques and utilize shielded power and control cabling to suppress electromagnetic interference (EMI).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Mark\u003c\/li\u003e\n  \u003cli\u003eUL Listed\u003c\/li\u003e\n  \u003cli\u003ecUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102148419947,"sku":"FR-E740-5.5K","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FR-E740-5.5K-cp4oawnawmo.png?v=1776137497","url":"https:\/\/www.plcprotech.com\/products\/mitsubishi-electric-fr-e740-5-5k-inverter-drive","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}