{"product_id":"mitsubishi-electric-fr-e840-0440-4-60-fr-e800-series-inverter","title":"Mitsubishi Electric FR-E840-0440-4-60 FR-E800 Series Inverter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Engineered for demanding motor control applications, the \u003cstrong\u003eMitsubishi Electric FR-E840-0440-4-60\u003c\/strong\u003e is a high-performance three-phase variable frequency drive designed for 400 V class power systems. Part of the highly adaptable \u003cstrong\u003eFR-E800\u003c\/strong\u003e series, this model offers robust performance with a Normal Duty (ND) rated current of \u003cstrong\u003e44.0 A\u003c\/strong\u003e. To ensure sustained reliability in demanding operational environments, this specific model features conformal-coated circuit boards (designated by the -60 suffix) to resist dust and moisture, while operating on source logic configurations for both digital input and integrated safety stop systems.\n\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eConformal Coated PCBs:\u003c\/strong\u003e Enhanced environmental protection against chemical, moisture, and particulate ingress in harsh industrial environments.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eFlexible Control Logic:\u003c\/strong\u003e Factory-configured for source logic control inputs and fixed source logic safety stop signals.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eVoltage Monitoring:\u003c\/strong\u003e Dedicated analog monitoring via the AM terminal voltage output interface.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003e\n\u003cstrong\u003eAdvanced Safety Design:\u003c\/strong\u003e Integrated safety-stop functionality ensures compliance with operational machinery safety directives.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHeavy-duty conveyor lines and bulk material handling systems.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eIndustrial centrifugal pumps, fans, and blowers in process plant environments.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eCompressors and mixers requiring precise torque and speed management.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eAutomated packaging machinery and mechanical handling apparatus.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; width: 40%;\"\u003eManufacturer\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMitsubishi Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eModel Number\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFR-E840-0440-4-60\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSeries\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFR-E800\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eVoltage Class\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e400 V Class (Three-Phase Input)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eInverter ND Rated Current\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e44.0 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eRated Frequency\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e50 Hz (Initial Setting)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eInput Control Logic\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSource Logic (Initial Status)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSafety Stop Signal\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSource Logic (Fixed)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eMonitoring Interface\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eVoltage (Terminal AM)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eCircuit Board Coating\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eWith Coating\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003ePlated Conductor\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eWithout Plated Conductors\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eNet Weight\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e11.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eShipping Weight\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e14.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The FR-E800 series is designed as an optimized upgrade path for legacy FR-E700 systems. When planning retrofits, note that while mounting footprints are highly similar, differences in terminal blocks and software parameter maps require review. Ensure that configurations from the older FR-E700 are migrated using FR Configurator2 to avoid parameter incompatibility, especially concerning safety logic configurations.\n\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  While the coated boards of the -60 variant provide substantial protection against dust and humidity, they do not eliminate the need for thermal management. When mounted in closed cabinets, ensure adequate space of at least 50 mm above and below the unit. High ambient temperatures without ventilation can trigger thermal overload faults (E.THT) even if current ratings remain below the nominal 44.0 A limit.\n\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Always ground the drive directly using the dedicated PE terminal to reduce high-frequency electrical noise. Motor cables should be shielded and run separately from control, signal, and communication lines by a minimum of 10 cm to prevent crosstalk on the AM terminal analog voltage signal.\n\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"font-weight: bold; color: #9b2c2c; margin: 0 0 0.5rem 0;\"\u003eCRITICAL SAFETY WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    Risk of hazardous voltage and electrical shock. Ensure that the primary AC power supply is completely de-energized and locked out. Wait a minimum of 10 minutes after disconnecting power to allow internal capacitors to discharge fully before removing the drive cover or touching terminal connections.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the inverter vertically to a flat, clean, and non-combustible vertical wall or panel surface.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the primary three-phase AC input supply to the power terminals L1, L2, and L3.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the motor output phases to terminals U, V, and W, and ensure the protective earth (PE) connection is secure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eEstablish the source logic wiring for the control and safety inputs according to the standard terminal layout.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: inline-flex; justify-content: center; align-items: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e5\u003c\/span\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eApply input power, access the programming menu, and set the basic motor nameplate parameters before commissioning the system.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102139867499,"sku":"FR-E840-0440-4-60","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/fr-e840-0440-4-60-o2ahiz3cz4j.png?v=1776137503","url":"https:\/\/www.plcprotech.com\/products\/mitsubishi-electric-fr-e840-0440-4-60-fr-e800-series-inverter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}