{"product_id":"mitsubishi-electric-fx3u-80mt-ds-fx3u-series-plc-base-unit","title":"Mitsubishi Electric FX3U-80MT\/DS FX3U Series PLC Base Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for demanding industrial control applications, the \u003cstrong\u003eFX3U-80MT\/DS\u003c\/strong\u003e serves as a high-speed, expandable controller within the MELSEC FX3U series. This compact programmable logic controller (PLC) features a dual-bus architecture, allowing for the integration of standard FX2N\/FX3U expansion blocks alongside specialized high-speed analog and communication adapters. Equipped with 40 DC inputs and 40 transistor outputs, this base unit delivers precise machine-level control and robust processing performance for automated machinery.\u003c\/p\u003e\n\n\u003cp\u003eThe unit operates on a 24V DC power source, making it highly suitable for mobile, marine, and decentralized industrial power architectures. It incorporates high-speed counter inputs and pulse outputs directly on the main board, simplifying positioning and motion control applications without requiring external hardware modules.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Bus Architecture:\u003c\/strong\u003e Supports left-side adapter bus (ADP) for high-speed communication and analog modules, plus right-side expansion bus for standard I\/O and special function blocks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Processing:\u003c\/strong\u003e Instruction execution speeds down to 0.065 microseconds per basic instruction.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile Inputs:\u003c\/strong\u003e 40 integrated 24V DC inputs configurable as sink or source.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSolid-State Outputs:\u003c\/strong\u003e 40 integrated transistor outputs (sink type) for rapid switching cycles and long operational life.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExpanded Memory:\u003c\/strong\u003e 64,000 steps of internal RAM programming memory, expandable with optional flash memory cassettes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Motion Control:\u003c\/strong\u003e Supports high-speed counters up to 100 kHz and independent pulse train outputs for stepper or servo drive positioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003ePackaging machinery and automated wrapping systems\u003c\/li\u003e\n  \u003cli\u003eMaterial handling systems and multi-axis conveyor control\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater treatment distribution panels\u003c\/li\u003e\n  \u003cli\u003eAssembly line automation and test bench systems\u003c\/li\u003e\n  \u003cli\u003eFood and beverage processing machinery\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eGeneral and Electrical Specifications\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFX3U-80MT\/DS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMELSEC FX3U\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAllowable Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20.4V DC to 26.4V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal I\/O Points\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e80 points (40 inputs, 40 outputs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24V DC (Sink \/ Source selectable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTransistor (Sink)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Voltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5V DC to 30V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Output Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5A per point (0.8A per common)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProgramming Memory\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64,000 steps RAM (internal)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to 75 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e35mm DIN rail or direct screw mounting\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e285 mm x 90 mm x 86 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Section\u003c\/th\u003e\n      \u003cth\u003eInterface Function\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Terminals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24V DC Power Input and Protective Earth (PE) ground connection.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Terminals (X000 - X047)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24V DC digital inputs, configurable for sink (S\/S connected to 24V) or source (S\/S connected to 0V).\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Terminals (Y000 - Y047)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTransistor outputs (sink type) connecting load to the negative common rail.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProgramming Port\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBuilt-in RS-422 interface (8-pin Mini-DIN) for programming software or HMI connection.\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Clearance:\u003c\/strong\u003e Install the PLC horizontally on a standard 35mm DIN rail. Maintain at least 50 mm clearance above and below the unit to ensure adequate ventilation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e Connect the ground terminal to an independent grounding point with a resistance of 100 ohms or less (Class D grounding). Do not share grounding lines with high-power equipment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring Protection:\u003c\/strong\u003e Use appropriate terminal lugs and verify terminal block screws are torqued to the specified limits (0.5 to 0.8 N-m) to prevent loose connections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Route high-voltage AC lines away from low-voltage DC input\/output signals and communication cables to minimize electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE (Electromagnetic Compatibility Directive)\u003c\/li\u003e\n  \u003cli\u003eUL Listed (US and Canadian safety standards)\u003c\/li\u003e\n  \u003cli\u003eKC (Korea Certification)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102153269611,"sku":"FX3U-80MT\/DS","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/FX3U-80MTDS-nkzyjlee3dv.png?v=1776137548","url":"https:\/\/www.plcprotech.com\/products\/mitsubishi-electric-fx3u-80mt-ds-fx3u-series-plc-base-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}