{"product_id":"mitsubishi-electric-gt2308-vtbd-got2000-series-hmi-panel","title":"Mitsubishi Electric GT2308-VTBD GOT2000 Series HMI Panel","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDirecting system operations through high-resolution graphical interfaces, the Mitsubishi Electric GT2308-VTBD provides an efficient visualization interface for medium-scale automation networks. This GOT2000 series operator interface combines flexible serial links, Ethernet capabilities, and reliable DC power system architectures to maximize operator response times. Engineered as an integrated monitoring node, this HMI utilizes an \u003cstrong\u003e8.4-inch VGA TFT display\u003c\/strong\u003e to present real-time diagnostics, alarm histories, and complex process graphics with high clarity and contrast.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eHigh-fidelity 8.4-inch TFT color LCD with 65,536 colors and crisp 640 x 480 dot resolution.\u003c\/li\u003e\n  \u003cli\u003eComprehensive onboard communication channels supporting Ethernet, RS-232, and RS-422\/485 serial standards.\u003c\/li\u003e\n  \u003cli\u003eIntegrated SD memory card slot enabling local data logging, program backup, and firmware recovery.\u003c\/li\u003e\n  \u003cli\u003eRobust front-panel sealing certified to IP67F, providing structural resistance against dust and low-pressure water sprays.\u003c\/li\u003e\n  \u003cli\u003eCompliant with 24V DC auxiliary electrical distribution frameworks for localized panel configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eAutomobile assembly and precision tooling line monitoring.\u003c\/li\u003e\n  \u003cli\u003ePackaging, sorting, and material handling control consoles.\u003c\/li\u003e\n  \u003cli\u003eWater treatment processing, pump control, and chemical dosing systems.\u003c\/li\u003e\n  \u003cli\u003eHVAC, cooling plant, and building management system coordination.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eMitsubishi Electric\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGT2308-VTBD\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eHMI Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGOT2000 (GT23)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDisplay Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e8.4 inches (213 mm) diagonal\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDisplay Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTFT color LCD\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e640 x 480 pixels (VGA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eInput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24V DC (+10%, -15%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e15W or less (Backlight OFF: 10W or less)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eUser Memory Capacity\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e9 MB built-in flash memory\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 to 55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eIngress Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP67F (equivalent to NEMA 4X front panel)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1.5 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2.2 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eInterface Type\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eConnector \/ Specification\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eFunction Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eEthernet Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eRJ-45 (10BASE-T\/100BASE-TX)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eHost PLC communication and multi-station networking\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSerial Port (RS-232)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eD-sub 9-pin male\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eDirect point-to-point PLC connection, peripheral access\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSerial Port (RS-422\/485)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eD-sub 9-pin female\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eMulti-drop networking, legacy PLC architectures\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eUSB Host\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eType A (USB 2.0 High Speed)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eUSB memory storage interface for data transfers\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eUSB Device\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eMini-B (USB 2.0 High Speed)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eDirect PC terminal programming connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe GT2308-VTBD utilizes a 24V DC bus structure. When substituting an older GOT1000 equivalent (such as the GT11 or GT15 series), ensure your existing utility power supplies can handle the DC current load, or consider the GT2308-VTBA if AC power is your primary standard. Project file databases are cross-compatible but require compilation and adjustment via GT Works3 software suites before execution.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo protect the internal liquid crystal matrix, avoid installing this HMI in positions subjected to prolonged direct sunlight or close proximity to thermal radiating bodies like continuous-duty breaking resistors. Confirm that any adjacent variable speed drives have adequate electrical shielding to prevent high-frequency noise interference over the serial communication paths.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eEnsure a dedicated functional ground wire (Class D grounding, wire size 2 mm squared or larger) is routed directly to the system backplate. Running HMI ground connections in common loops with high-inductive loads can lead to touchscreen input instability or communications dropouts.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0;\"\u003eCRITICAL WARNING:\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003eIsolate and lock out all upstream electrical power supplies prior to panel mounting or interface wiring. Verify with an active voltmeter that the 24V DC input cable is fully de-energized. Performing connections on live terminals will damage delicate internal transceiver chips and void product certifications.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; flex-shrink: 0; font-weight: bold;\"\u003e1\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003ePerform panel-cutout procedures to accommodate the physical dimensions of the HMI unit. Clean and deburr all sheet metal edges before fitting.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; flex-shrink: 0; font-weight: bold;\"\u003e2\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eInsert the rubber waterproofing gasket into the HMI channel. Place the unit into the panel opening and verify the gasket is seated flat to ensure IP67F sealing performance.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; flex-shrink: 0; font-weight: bold;\"\u003e3\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eTighten the physical mounting brackets around the back of the HMI frame using a progressive star pattern. Avoid over-tightening to prevent plastic frame deformation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; flex-shrink: 0; font-weight: bold;\"\u003e4\u003c\/span\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eTerminate the 24V DC auxiliary lines and separate communication cables to their dedicated ports before initiating power commissioning checks.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53102126825835,"sku":"GT2308-VTBD","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/gt2308-vtbd-suz1wf3qa4d.png?v=1776137608","url":"https:\/\/www.plcprotech.com\/products\/mitsubishi-electric-gt2308-vtbd-got2000-series-hmi-panel","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}