{"product_id":"notifier-by-honeywell-30-3013-explosion-proof-smoke-detector","title":"Notifier by Honeywell 30-3013 Explosion-Proof Smoke Detector","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Notifier 30-3013 is a high-performance explosion-proof smoke detector engineered for hazardous industrial locations. This unit utilizes a light-scattering infrared photodiode sensor for reliable detection of both smoldering and flaming fires. Designed for integration into fire alarm control panels (FACP) via 2-wire or 4-wire configurations, it is primarily deployed in oil and gas refineries, chemical processing plants, offshore platforms, and volatile storage facilities. The assembly consists of a precision-engineered smoke sensor head and a heavy-duty, copper-free aluminum junction box designed to contain internal explosions and prevent the ignition of external flammable atmospheres. It maintains stable operation across a wide temperature range and is compatible with various industrial fire suppression systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30-3013\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNotifier by Honeywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExplosion-Proof Smoke Detector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhotoelectric (Light-scattering)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 - 32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 mA (Alarm), 100 µA (Standby)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Material (Sensor)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolycarbonate \/ ABS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Material (J-Box)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCopper-free aluminum (painted)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20°C to 65°C (–4°F to 149°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–55°C to 70°C (–67°F to 158°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% RH (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.0 Kg (approx. 11 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArea Classification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass I, Div 1 \u0026amp; 2, Groups B, C, D; Class II, Div 1 \u0026amp; 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNEMA 4X \/ IP66 (Junction Box)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003ch3\u003eField Wiring and Grounding\u003c\/h3\u003e\n\u003cp\u003eWhen installing the 30-3013 in hazardous areas, all field wiring must comply with the National Electrical Code (NEC) or local equivalent standards for Class I\/II locations. Use shielded twisted pair cable for 2-wire loops to minimize electromagnetic interference (EMI). Ensure the junction box is properly grounded via the internal grounding screw to prevent static buildup and ensure the integrity of the flamepath.\u003c\/p\u003e\n\u003ch3\u003eReplacement and Maintenance\u003c\/h3\u003e\n\u003cp\u003eThe smoke detector head is calibrated to specific sensitivity levels at the factory. During routine maintenance, do not attempt to disassemble the sensor head. If the unit fails self-diagnostics or enters a fault state during testing, the sensor assembly must be replaced as a single unit. Always verify that power is disconnected before opening the explosion-proof junction box to prevent ignition risks.\u003c\/p\u003e\n\u003ch3\u003eEnvironmental Considerations\u003c\/h3\u003e\n\u003cp\u003eWhile the junction box is rated for industrial use, the smoke entry ports must be kept clear of heavy dust accumulation or paint overspray. In high-vibration environments, ensure all conduit entries are secured with approved explosion-proof seals (EYS) to prevent moisture ingress and flame propagation through the conduit system.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 30-3013 compatible with third-party Fire Alarm Control Panels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the 30-3013 is designed to operate on standard 2-wire or 4-wire 24VDC loops, making it compatible with most industrial FACPs that support conventional smoke detectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the sensitivity of the detector verified in the field?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSensitivity testing should be performed using calibrated aerosol smoke or specialized testing equipment designed for explosion-proof housings. There is no manual sensitivity adjustment on the unit to ensure factory-set safety thresholds are maintained.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the recommended replacement cycle for the sensor head?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn accordance with NFPA 72 guidelines and typical industrial lifecycle management, it is recommended to inspect the unit annually and consider replacement every 10 years, or sooner if deployed in highly corrosive or oil-mist heavy environments.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52679374569835,"sku":"30-3013","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/30-3013-jl4loghus5w_69345a43-90fb-4530-bf68-0a412f966d3b.jpg?v=1765958285","url":"https:\/\/www.plcprotech.com\/products\/notifier-by-honeywell-30-3013-explosion-proof-smoke-detector","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}