{"product_id":"omron-3g3mx2-a4055-zv1-mx2-series-multi-function-compact-inverter","title":"Omron 3G3MX2-A4055-ZV1 MX2 Series Multi-Function Compact Inverter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eOptimized speed and torque regulation in heavy-duty automated machinery is achieved through the integration of the \u003cstrong\u003eOmron 3G3MX2-A4055-ZV1\u003c\/strong\u003e variable frequency drive. Representing the highly modular and compact \u003cstrong\u003eMX2 Series\u003c\/strong\u003e, this industrial inverter is engineered to deliver dynamic \u003cstrong\u003ethree-phase 400 V AC\u003c\/strong\u003e motor control up to a capacity of \u003cstrong\u003e5.5 kW\u003c\/strong\u003e. With its integrated functional safety architecture and advanced vector control algorithms, the drive ensures stable performance under high starting torque demands, adapting seamlessly to complex machine environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eAdvanced open-loop current vector control providing 200% starting torque at frequencies as low as 0.5 Hz.\u003c\/li\u003e\n  \u003cli\u003eDual safety inputs (S1 and S2) conforming to ISO13849-1 Cat. 3 \/ PLd standards for integrated Safe Torque Off (STO) functions.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in Modbus RTU communication over a standard RS-485 interface for easy network configuration.\u003c\/li\u003e\n  \u003cli\u003eRobust IP10-rated enclosure design optimized for internal panel mounting and space-saving side-by-side layout.\u003c\/li\u003e\n  \u003cli\u003eIntegrated drive programming platform allows execution of custom logical sequences and decentralized control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eHigh-torque material handling conveyor lines and automated sorting equipment.\u003c\/li\u003e\n  \u003cli\u003eIndustrial fans, centrifugal air blowers, and positive displacement fluid pumps.\u003c\/li\u003e\n  \u003cli\u003eProcessing machinery including industrial mixers, small extruders, and rotary packaging tools.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eValue \/ Rating\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3G3MX2-A4055-ZV1\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSeries Name\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMX2 Series Multi-Function Compact Inverter\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInput Voltage Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3-Phase 380 to 480 V AC (+10% \/ -15%), 50\/60 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMax Applicable Motor Capacity (CT)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e5.5 kW (Heavy Duty)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eEnclosure Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP10 Minimum (Panel-mounting)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCommunication Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eModbus RTU (via built-in RJ45 physical layer)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSafety Standard\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eISO13849-1 Cat. 3 \/ PLd Compliant\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3.5 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e6.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe \"ZV1\" designation in the model number marks the standardized firmware revision equipped with permanent magnet (PM) motor vector control capability alongside induction motor control. This unit acts as a physical drop-in replacement for older non-ZV1 variants of the same 5.5 kW power frame size, though parameter mappings for safety loop configurations must be verified during system retrofit procedures.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDuring heavy-load, continuous duty operations, avoid placing the inverter in unventilated enclosures where internal temperatures exceed 40 degC without systematic derating. Maintaining a minimum clearance of 100mm both above and below the cooling heatsink is mandatory to prevent thermal trip warnings under sustained load profiles.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen setting up the Safe Torque Off (STO) circuit, ensure that the safety jumper between standard terminal ports is removed before wiring to external safety relays. It is highly recommended to run the motor feed cables through shielded conduits separated from low-level control and feedback signals to eliminate high-frequency electromagnetic interference.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING: HIGH VOLTAGE\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eDisconnect all primary power sources and verify zero potential across the DC bus terminals prior to initiating installation or maintenance. Wait a minimum of 10 minutes post-power de-energization to allow internal capacitors to safely discharge stored electrical charge.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 15px; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Securely mount the chassis vertically inside an electrical cabinet. Retain standard side gaps if mounting multiple inverters side-by-side.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 15px; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003ePower Terminals Connection:\u003c\/strong\u003e Wire the three-phase 400 V AC supply to terminals L1, L2, and L3. Connect the output motor leads directly to terminals U, V, and W. Ensure a solid, low-impedance ground connection.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"display: flex; align-items: center; justify-content: center; width: 30px; height: 30px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 15px; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      \u003cstrong\u003eControl and Safety Integration:\u003c\/strong\u003e Route external control signals through the dedicated terminal strip, keeping signal and safety-loop lines properly shielded and separated from the high-power input\/output runs.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077911437675,"sku":"3G3MX2-A4055-ZV1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3g3mx2-a4055-zv1-nwobilca0rr.png?v=1775733443","url":"https:\/\/www.plcprotech.com\/products\/omron-3g3mx2-a4055-zv1-mx2-series-multi-function-compact-inverter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}