{"product_id":"omron-3g3mx2-a4150-zv1-mx2-series-v1-type-multi-function-compact-inverter","title":"Omron 3G3MX2-A4150-ZV1 MX2-Series V1 type Multi-Function Compact Inverter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Omron \u003cstrong\u003e3G3MX2-A4150-ZV1\u003c\/strong\u003e is a multi-function compact AC variable frequency inverter within the MX2-Series V1 type family, engineered to regulate three-phase asynchronous induction motors and permanent magnet synchronous motors. Operating on a 400V class three-phase voltage supply, this unit performs harmonic output generation to control heavy industrial machinery requiring high starting torque and dynamic speed adjustment. The system functions with an integrated physical safety architecture and incorporates internal logic programming capabilities for customized macro sequence configuration. It features discrete multi-function digital inputs, dedicated safety inputs, analog command interfaces, and monitoring outputs to facilitate local hardware control. The drive supports flexible communication scaling via optional network interfaces, ensuring complete compatibility with standard factory fieldbus systems like EtherCAT, EtherNet\/IP, CompoNet, DeviceNet, and Modbus architectures.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual motor compatibility supporting both high-efficiency induction motors and permanent magnet synchronous motors.\u003c\/li\u003e\n\u003cli\u003eHigh torque output generating up to 200 percent starting torque near a stand-still frequency of 0.5 Hz.\u003c\/li\u003e\n\u003cli\u003eBuilt-in machine safety functionality conforming to ISO 13849-1 Category 3 Performance Level PLd.\u003c\/li\u003e\n\u003cli\u003eTwo hardware safety inputs along with an External Device Monitoring status output terminal.\u003c\/li\u003e\n\u003cli\u003eFlow chart and text editor logic programming enabling up to 5 parallel tasks inside the drive.\u003c\/li\u003e\n\u003cli\u003eModbus communication interface integrated as standard on the core control terminal board.\u003c\/li\u003e\n\u003cli\u003eModular communications chassis designed to accept plug-in option cards for industrial field networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-inertia material transport conveyor systems and heavy-duty logistics sorting lines.\u003c\/li\u003e\n\u003cli\u003eRapid cyclic production machines, fast indexing machinery, and packaging systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial fluid pumping units, multi-stage ventilation fans, and blending machinery.\u003c\/li\u003e\n\u003cli\u003eVertical or horizontal material handling cranes, hoisting equipment, and positioning setups.\u003c\/li\u003e\n\u003cli\u003eMachine tool auxiliary spindles, automated winding units, and continuous web handling lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eMX2-Series V1 type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eStarting Torque\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e200 percent at 0.5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSupported Motor Types\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eInduction Motor (IM), Surface Permanent Magnet Motor (SPM), Interior Permanent Magnet Motor (IPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eSpeed Tuning Feature\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eOne-parameter auto-tuning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eParallel Logic Executions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eUp to 5 tasks simultaneously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePower Requirements\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eVoltage Class\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e400V 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eApplicable Motor Capacity\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eInput\/Output\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eSafety Inputs\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e2 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eSafety Feedback Monitor\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eExternal Device Monitoring (EDM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eSerial Interface\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eModbus communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eProtection\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eSafety Norm Conformance\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eISO 13849-1 Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003ePerformance Level\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003ePLd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Airflow Control:\u003c\/strong\u003e Secure the drive vertically onto an unpainted metal backplate inside a sealed electrical sub-panel enclosure. Maintain required spatial clearances above and below the cooling heatsinks to allow vertical convection airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Power Safety:\u003c\/strong\u003e Wait for a minimum period of 10 minutes following a complete line power disconnection before accessing the internal terminal layout blocks or removing the front panel cover assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Terminate a low-impedance copper safety earth ground directly to the primary hardware ground terminal plate. Wrap all primary motor supply wires in a continuous braided metal shield connected 360 degrees to the ground plane to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Separated Channels:\u003c\/strong\u003e Route low-voltage analog signal wires, digital macro input wires, and safety circuit cables inside individual wiring ducts completely separate from heavy AC power input and motor output lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Termination:\u003c\/strong\u003e Enable standard matching inline network termination resistors when attaching optional fieldbus blocks like EtherCAT or DeviceNet at the physical termination nodes of the system network.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat types of electrical motors can this inverter unit control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe hardware is designed to drive standard induction motors as well as surface permanent magnet and interior permanent magnet synchronous motors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum operational safety standard satisfied by the internal circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe integrated safety components conform to the ISO 13849-1 Category 3 standard, achieving an official performance rating of PLd.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much mechanical torque can this controller supply when starting up a load?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe drive provides up to 200 percent starting torque at an output frequency near a stand-still level of 0.5 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this inverter require a separate PLC for simple automated sequences?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, it includes built-in flowchart programming and text editing interfaces that execute up to 5 parallel logic tasks directly on the drive.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the voltage rating and the target motor power limit for this specific model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis model is built for 400V three-phase networks and is rated for an applicable motor capacity of 15 kW.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many dedicated safety inputs are provided on the terminal interface?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features 2 discrete hardware safety inputs along with an External Device Monitoring terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat fieldbus communication network option modules can be installed into this chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe architecture accepts optional plug-in modules for communication networks including EtherCAT, EtherNet\/IP, CompoNet, and DeviceNet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs any network protocol available on the device without adding extra cards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, standard Modbus serial communication capability is integrated natively onto the core terminal board.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long must an engineer wait after disconnecting the power before servicing wires?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn engineered safety delay of at least 10 minutes must be observed to allow internal capacitors to discharge fully.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the one-parameter auto-tuning feature?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt allows safe and smooth configuration matching by simply inputting the baseline kilowatt rating of the connected motor.\u003c\/p\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077915730283,"sku":"3G3MX2-A4150-ZV1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3g3mx2-a4150-zv1-or5s3aovqad.png?v=1775733448","url":"https:\/\/www.plcprotech.com\/products\/omron-3g3mx2-a4150-zv1-mx2-series-v1-type-multi-function-compact-inverter","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}