{"product_id":"omron-cp1e-e60sdr-a-cp1e-series-cpu-unit","title":"Omron CP1E-E60SDR-A CP1E Series CPU Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for cost-effective standalone machine automation, the \u003cstrong\u003eOmron CP1E-E60SDR-A\u003c\/strong\u003e delivers high-density control with integrated physical inputs and outputs in a unified footprint. This basic-type CPU unit simplifies small-scale processes by incorporating \u003cstrong\u003e36 DC inputs\u003c\/strong\u003e and \u003cstrong\u003e24 relay outputs\u003c\/strong\u003e, minimizing the need for immediate expansion hardware. Equipped with an integrated USB programming interface, this controller is engineered for straightforward commissioning and reliable performance across industrial machinery applications requiring robust, entry-level logic processing.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eHigh-density physical layout providing 60 built-in I\/O channels.\u003c\/li\u003e\n  \u003cli\u003eIntegrated USB 2.0 peripheral port for direct connection and programming via CX-Programmer.\u003c\/li\u003e\n  \u003cli\u003eAC-powered input stage compatible with standard plant voltages.\u003c\/li\u003e\n  \u003cli\u003eRelay outputs capable of directly switching moderate current loads.\u003c\/li\u003e\n  \u003cli\u003eCompact, DIN-rail mountable enclosure designed to optimize control panel space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eConveyor and material handling control systems.\u003c\/li\u003e\n  \u003cli\u003ePackaging, wrapping, and labeling machinery.\u003c\/li\u003e\n  \u003cli\u003eIndustrial fan, pump, and ventilation sequencing.\u003c\/li\u003e\n  \u003cli\u003eDedicated municipal water treatment logic panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eOmron\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCP1E-E60SDR-A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eController Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCP1E (Basic E-type, Renewal S-type)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e100 to 240 VAC (50\/60 Hz)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e85 to 264 VAC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTotal I\/O Points\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e60 (36 inputs, 24 outputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInput Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 VDC inputs (compatible with sink or source sensors)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOutput Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRelay outputs (2 A max per point)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProgramming Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUSB 2.0 (Type-B connector)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eUnit Dimensions\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e190 mm x 90 mm x 78 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eNet Unit Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.85 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe CP1E \"E\" suffix designates a Basic-type architecture. Unlike the \"N\" (Application) series (such as the CP1E-N60SDR-A), this E-type module lacks built-in RS-232C or RS-485 serial communication ports, option board slots, and analog processing options. Ensure your network requirements do not require serial Modbus or master\/slave topologies before deploying this Basic-type variant.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBe aware that the CP1E-E60SDR-A does not feature an internal Real-Time Clock (RTC). Logistical steps, automated daily operations, or event logging with standard time-of-day execution cannot be processed natively on this controller. Additionally, when switching highly inductive elements (such as solenoid coils or contactors), external surge suppression (RC snubbers for AC, flyback diodes for DC) must be installed to prevent premature contact wear on the integrated 2 A relays.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003eVerify the connection configuration of your DC inputs. The common terminal can be wired as either sink (NPN) or source (PNP) depending on the 24 VDC polarization. Always earth-ground the Functional Ground (FG) terminal and the Protective Ground (GR) terminal separately to prevent electric noise on the USB connection during online program editing, which can otherwise trigger communications timeouts in CX-Programmer.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Isolate all primary and auxiliary AC line voltage sources before mounting, wiring, or handling the CP1E unit. Failure to completely de-energize the incoming supply rails can result in fatal electrical shock, terminal damage, or localized control circuit failures.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eMount the CPU unit horizontally on a 35 mm symmetric DIN rail, leaving at least 20 mm of space on both sides and 50 mm above and below for optimal thermal convective airflow.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the external AC power supply (100 to 240 VAC) to the L1 and L2 terminals, ensuring proper wire gauge allocation and tight terminal screws. Do not connect power to the physical I\/O terminals.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eEstablish the common connections for physical sensors on the digital input block, then connect field outputs to the relay terminals following correct polarity constraints.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 12px; font-weight: bold;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eApply main system power, establish connection with CX-Programmer using a standard shielded USB cable, and run diagnostics to confirm zero hardware system faults (ERR\/ALM LED remains off).\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077935456619,"sku":"CP1E-E60SDR-A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cp1e-e60sdr-a-tf1ikhbizdn.png?v=1775733572","url":"https:\/\/www.plcprotech.com\/products\/omron-cp1e-e60sdr-a-cp1e-series-cpu-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}