{"product_id":"omron-cp1e-na20dr-a-cp1e-series-cpu-unit-with-built-in-analog-i-o","title":"Omron CP1E-NA20DR-A CP1E-series CPU Unit with Built-in Analog I\/O","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Omron CP1E-NA20DR-A is an all-in-one programmable logic controller belonging to the CP1E-series, designed to handle small-scale automation sequences and basic machine processing. Operating on an alternating current line supply, this application controller incorporates integrated high-speed counters, pulse outputs, and built-in analog control channels. The base block features a combination of 20 discrete digital input\/output points alongside dedicated analog voltage\/current inputs and an analog output channel. It contains an integrated USB peripheral port for high-speed logic download, monitoring, and debugging configuration. The unit is engineered for compact machine-level automation architectures and retains modular system compatibility with standard CP1W expansion modules to scale discrete and analog capacities based on physical application definitions.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete application logic processor featuring integrated digital and analog capability on a unified chassis.\u003c\/li\u003e\n\u003cli\u003eBuilt-in discrete allocation supplying 12 inputs and 8 relay outputs.\u003c\/li\u003e\n\u003cli\u003eIntegrated analog I\/O block containing 2 analog inputs and 1 analog output as standard.\u003c\/li\u003e\n\u003cli\u003eNative high-speed USB peripheral programming interface facilitating direct engineering link connection.\u003c\/li\u003e\n\u003cli\u003eHigh-speed pulse acquisition capabilities designed for direct encoder feedback tracking.\u003c\/li\u003e\n\u003cli\u003eScalable construction footprint through support for standard CP1W option modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLocalized material transport mechanisms and small product conveyor installations.\u003c\/li\u003e\n\u003cli\u003eBasic automated fluid handling skids, batching mixers, and small dosing systems.\u003c\/li\u003e\n\u003cli\u003eCommercial packaging equipment, including wrapping, forming, and tape sealing machines.\u003c\/li\u003e\n\u003cli\u003eFacility climate control ventilation systems, fan sequences, and water pumping stations.\u003c\/li\u003e\n\u003cli\u003eDedicated laboratory testing jigs and standalone automated component assembly benches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eCP1E Application CPU Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eProgram Capacity\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e8K steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eData Memory Capacity\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e8K words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eProcessing Execution Speed\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eBasic instructions: 1.19 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePower Requirements\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eSupply Input Voltage Range\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e100 to 240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e50 VA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eInput\/Output\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eTotal Digital Built-In I\/O\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e20 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eDiscrete DC Inputs\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e12 inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e8 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eOutput Switching Mechanism\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eRelay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eIntegrated Analog Inputs\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e2 inputs (Resolution: 1\/6000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eIntegrated Analog Outputs\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e1 output (Resolution: 1\/6000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCommunication\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003ePeripheral Channel Interface\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eUSB 2.0 B-type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eAmbient Operating Temperature Range\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eStorage Ambient Temperature Range\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003e-20 to 75 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eAmbient Operating Humidity Limit\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e10 percent to 90 percent RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Assembly:\u003c\/strong\u003e Snap the controller module horizontally onto a standard 35mm DIN rail profile inside the control sub-panel. Fasten robust end blocks at both side margins to lock the system architecture against lateral shifting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Spacing and Airflow:\u003c\/strong\u003e Secure the unit exclusively in a horizontal mounting plane. Maintain an unhindered spacing buffer of at least 50 mm above and below the structural chassis to encourage steady air convection through the housing slots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Supply Infrastructure:\u003c\/strong\u003e Wire incoming alternating current lines directly to the labeled L1 and L2 power terminals. Use distinct inline circuit breakers to safeguard the sensitive internal rectifier stages from industrial grid surge fluctuations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Cable Separation:\u003c\/strong\u003e Position low-voltage discrete wiring paths and analog signal cables inside dedicated wireways separate from high-current AC output relay links or motor contactor power lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Earth Grounding:\u003c\/strong\u003e Establish a direct low-impedance copper link from the functional earth grounding terminal screw to the primary structural panel ground distribution bar.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the complete layout breakdown of the integrated digital points on this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe hardware contains a total of 20 discrete digital points, configured specifically as 12 inputs and 8 relay outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this model support direct analog voltage or current instrumentation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it features a built-in analog block that includes 2 analog input channels and 1 analog output channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power source is required to drive the internal electronics?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit operates on an alternating current infrastructure with a rated line level of 100 to 240 V AC at 50\/60 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat kind of physical interface is provided for programming download and setup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn integrated USB 2.0 B-type peripheral interface port is located directly on the front faceplate for engineering connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of switching elements are implemented on the discrete output block?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is built with electromechanical relay outputs, providing dry contact switching suitable for both AC and DC auxiliary loads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the baseline input and output capacity of this specific unit be scaled upwards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the hardware capacity can be expanded by attaching standard Omron CP1W series option units and I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the operational ambient temperature rating for inside an electrical cabinet?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe safe ambient operating window for this equipment spans from 0 to 55 deg C without active condensation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat memory capacity is allocated for the program sequence storage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe internal micro-processor provides a standard program memory capacity of 8K steps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the execution cycle speed for processing basic instructions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe baseline logic processing hardware executes standard instructions at a rate of 1.19 microseconds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it safe to install this programmable controller in a vertical layout?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the controller must always be mounted horizontally to ensure adequate convection airflow passes across the integrated cooling paths.\u003c\/p\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":53077900493163,"sku":"CP1E-NA20DR-A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/CP1E-NA20DR-A-kvpipskskxx.png?v=1775733591","url":"https:\/\/www.plcprotech.com\/products\/omron-cp1e-na20dr-a-cp1e-series-cpu-unit-with-built-in-analog-i-o","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}